JUDO PROFI-PLUS / JUDO PROFI-QC
21
Data sheet
9.4
Technical data
The following applies for all the models of
the device:
–
Nominal flow rate after backwashing at a
pressure loss of 0.2 (0.5) bar as given in
the table
–
Maximum ambient temperature and wa-
ter temperature: 30 °C (86 °F)
–
The water to be filtered must conform
to the European Drinking Water
Regulations!
–
Threaded connection to DIN EN 10226-1
The backwashing volumetric flow given applies to 2 - 3 bar mains pressure and for a com-
pletely opened flushing water valve.
Nominal pressure
Model
Operating
pressure
Nominal
pressure
JPF
+
¾" - 1¼"
JPF-QC
1½" - 2"
1.5 - 16 bar PN 16
Model
Weight
Nominal flow rate after backwashing
at a pressure loss of 0.2 (0.5) bar
and clean sieve
Back-flush volume
stream
JPF
+
¾"
2.6 kg
4.1 (6.7) m³/h
0.2 - 0.4 l/s
JPF
+
1"
2,7 kg
4.7 (7.6) m³/h
0.2 - 0.4 l/s
JPF
+
1¼"
3,3 kg
5.3 (8.5) m³/h
0.2 - 0.4 l/s
JPF-QC
1½"
9.0 kg
13.0 (18.0) m³/h
0.3 - 0.8 l/s
JPF-QC
2"
10.2 kg
16.0 (22.0) m³/h
0.3 - 0.8 l/s