20
6.3
Shutting down
Switch the power supply of the JUDO fault indicator off if the corresponding water
softening system is out of service or shut down.
7
Inspection, maintenance, service
Switch off the power supply before working on device components!
Servicing and maintenance could only be performed by JUDO customer service or
authorised technical personnel and while adhering to the applicable safety conditions!
Orderly and systematically performed servicing is the underlying requirement for a fault-
free long service life of the JUDO fault indicator
(Observe DIN EN 806-5:2012)!
According to DIN EN 806-5:2012, every technical plant requires regular servicing and inspection. The
inspection should be performed at intervals of 2 months by trained personnel and servicing at half-yearly
intervals within the scope of the associated water softening system servicing. Both must always be
performed by JUDO customer service or an authorised specialist company, who will if necessary replace
defective parts or wear parts. We recommend that you set up a customer service contract, so that your
JUDO fault indicator can be regularly tested for fault free operation.
7.1
Spare parts
Designation
Order no. Pc.
Control unit fault indicator
1510180
1
Mains power connector
1500518
1
Camshaft microswitch (fault indication kit) 1500376
1
Front microswitch (fault indication kit)
1500414
1
Tab. 6: Spare parts