Operation
JUDO QUICKSOFT MEGA 4
15
– Factory setting
(see chapter 5.14 “Resetting to factory
setting”)
Operating data
– Total soft water volume since commis-
sioning [m³]
– Total number of regenerations since
commissioning
– Total number of maintenances since
commissioning
Info
Various information is displayed here such
as device type, device number, customer
service telephone number, history of the
warning messages and fault indications,
software version, hardware version and the
date for the next necessary maintenance in-
tervention.
5.4
Start of operation
– To shorten commissioning, fill approxi-
mately 5 litres of water into the salt res-
ervoir
(until just above the intermediate
floor).
– Fill 25 - 50 kg of regenerating salt into
the salt reservoir.
The regenerating salt must as a minimum
comply with the requirements of DIN EN 973
and be of food-grade.
Our recommendation:
Broxo or Solvay
salt, either as blocks, tablets or coarse
grains 7 - 15 mm. If other regenerating salts
are used, then the salt reservoir
must be
cleaned at shorter intervals and the intake
strainer replaced more frequently.
– Remove the cover.
– Enter the date of installation on the label
– Open the water supply (stopcock or
shut-off valve).
– Ensure that the bypass valve (if in-
stalled) is set to “Operate”.
NOTICE
For safety reasons, the water softening sys-
tem must be
immediately
flushed and re-
generated for bleeding
.
See chapters 5.4.1 and 5.4.2 for this pur-
pose!
5.4.1 Flushing the water softening
system
– To do so open a tap (as close as possi-
ble to the water softening system) and
create a volume flow of about 500 l/h.
– After a minute’s flushing (both resin con-
tainers are vented), plug the power sup-
ply unit into the socket.
After connection to the power supply, the
electronics automatically perform a self-test.
Status display:
After a successful conclusion, the following
text is output to the display:
Fig. 9:
Device and order no. plus
Label “Date of installation”
Fig. 10: Status display
Device-no.
Order no.
Label
“Date of installation”
Operating
QUICKSOFT-P
Summary of Contents for 8200367
Page 3: ...JUDO QUICKSOFT MEGA 4 3...
Page 18: ...Operation 18 JUDO QUICKSOFT MEGA 4 5 5 Menu structure Fig 12 Menu structure...
Page 27: ...Data sheet JUDO QUICKSOFT MEGA 4 27 Fig 14 Electronic control unit with fault message relay...
Page 30: ...30 JUDO QUICKSOFT MEGA 4 Notes...
Page 31: ...JUDO QUICKSOFT MEGA 4 31 Notes...