UC-900RX
ACTIVE ANTENNA COMBINER
The UC-900RX is designed for receivers. It provides 2 x 4 antenna inputs to minimize RF dead zone on a stage or any
venue. It also feature RF input ON/OFF, input attenuation from -31 to 0 dB and input signal ON/OFF control. The
UC-900RX makes RF engineers’ job easy.
Instruction Manual
Specifications
Accessories
Operating Controls
•
AC Power Cable x1
•
BNC to BNC coaxial Cable x2
Power switch
Antenna setting key: Select the CH to be set, press and hold for 2 seconds to enter the setting mode.
Up / Down key: In the setting mode, press the up / down key to select the parameter.
Key lock: long press 2 seconds to lock or unlock the panel key function.
3-digit seven-segment display: Displays the current setting.
Function selection indicator: In the setup mode, the indicator flashes in this order:
RF input attenuation, antenna Booster power on / off, RF input enable / disable.
Status indicator: Indicates the current antenna status,
UC-900RX
Front Panel
2
7
3
5
4
Caution : To reduce the risk of fire or shock hazard, do not expose this appliance to heat or moisture.
Warning : To prevent electric shock, do not remove the cover. Refer all servicing to qualified service personnel or distributors.
1. Read this instruction manual before using.
2. Keep this instruction manual.
3. Use the device in a well ventilated area. Do not block any ventilation openings.
4. Do not install the device near heat sources, Ex : Oven, furnaces or any other
apparatus that produce heat to prevent fire.
5. Do not place the device in humid or dusty environment to prevent short circuit.
6. Choose proper place to place the device to avoid product failure or personal
injury caused by accidental drops.
7. Do not use the device under lighting to avoid personal injury or equipment
damage caused by strikes.
8. Stop using and turn off the power when encounter abnormal situation. Contact
qualified service personnel or distributors.
> Machine has smoke or burning smell
> Water or any liquid has been spilled
9. Keep the machine outlet or plug clean. Dust gathering may result in bad
connection or electric fire.
10. Pay attention to the cable usage
> Hold the plug when unplugging. Breaking the wire may result in electric fire.
> Do not cut or twist the wire. Place the wire in a well ventilated area without
inflammable objects.
• Carrier Frequency Range: 470~960MHz
• Full System Gain: 3dB(±3dB)
•
Input/Output Impedance: 50 Ω
• A/B Antenna Input:4+4
• OIP3: 35dBm(typ.) @ 2-tone
;
Pi=-15dBm/tone
• RF Input Attenuation: -31~0dB (Step:1dB)
• Input/Output Connectors: BNC(F):Input x8 / Output x2
• Functions:
1. Antenna Booster Powering ON/OFF Control
2. RF Input Attenuation Control
3. RF input Signal ON/OFF Control
• Antenna Booster Power: 12V/200mA*8
• Power Supply: 100~240VAC; MAX 2A 50/60Hz
• Dimension(mm): 480mm(W)*45mm(H)*260mm(D)
1
2
3
5
4
6
7
a. Red: RF input enabled and antenna booster power on.
b. Green: RF input enabled and antenna booster power off.
c. Off: The antenna input is disabled.
d. All 8 channels flashing at the same time: Power supply is abnormal. Please shut down immediately.
RF ATT
A1
A2
A3
A4
B1
B2
B3
B4
RX Antenna Combiner
UC-900RX
ANT Powering
RF Input
SET
SET
6
To enter the setting mode, press and hold the antenna setting key
for 2 seconds until the input channel’s status
indicator
flashes. Use the Antenna setting key to cycle through the 3 settings menus as indicated by the Function
Selection Indicator
. Use the Up/Down keys
to change the parameters in each settings mode. After setting your
parameters in the third setting mode(RF Input), press the Antenna Setting Key
a final time to save and exit the settings.
Parameter setting:
RF input attenuation
Press the up / down key
to adjust the attenuation with interved of 1dB.
0dB: no attenuation
-31dB: attenuation of 31dB
Antenna power supply
On: P 12Vdc / 200mA to antenna inputs for active antenna or antenna booster.
OFF: OFF
RF Input
En: Input Enable (Enable)
dis: input disabled (Disable); signal isolation: about 80dB
Default setting
1. Turn off the power
2. Press and hold the lock key
3. Turn on the power until the display show rSt
Operation
Precautions
•This product is used as the antenna integrator of the receiver, which is not recommended to be used with a transmitter.
• For the coaxial cable with antenna and UC-900RX, standard 50Ω coaxial cable must be used.
• When the antenna is connected to the unit with the coaxial cable, it is recommended to use Booster to compen sate for
cable loss or use 5D-FB coaxial cable.
• It is not advisable to place the antenna in the same space or where there are too much reflecting planes as they cause
multipath interference of the signal and affect the reception quality.
• When the antenna input signal is too large, it may cause distortion of the unit or receiver signal. If this is the case, try
adjusting the antenna input attenuation.
• When the power supply is abnormal, the panel light will flash and the machine will force to shut down all the corresponding
functions. Please turn off the power switch immediately.
RF ATT
ANT Powering
RF Input
-10
Attenuation of
10dB
RF ATT
ANT Powering
RF Input
ANT Powering
RF ATT
ANT Powering
RF Input
RF Input Enable
59010-531-03
RF ATT
ANT Powering
RF Input
1
4
PROFESSIONAL CO., LTD.
No. 148, 9th Industry Road, Ta-Li Industrial Park,
Taichung City, Taiwan, R.O.C.
Tel: 886-4-24938803 Fax: 886-4-24914890
E-mail: [email protected]