background image

©JRI Maxant 

 

25 

XXII.

 

WARRANTY 

JRI Maxant products carry a one year warranty and guarantee against defects in their components or workmanship. 
During this period if any product supplied by the Company proves on inspection to be defective, the Company will at its 
own option replace the same or refund to the Buyer the price of the product. 
In  no  circumstances  will  JRI  Maxant'  liability  exceed  the  price  of  the  product  paid  by  the  buyer  or  the  cost  of 
replacement. 
JRI  Maxant  shall  not  in  any  event  be  liable  to  the  Buyer  for  any  indirect  or  consequential  loss  or  damage  costs  or 
expenses whatsoever which might arise out of or in connection with the supply of the product or its consequent use. 
Consequently, the products warrantee and guarantee specified above, does not cover damage caused by fair wear and 
tear, abnormal storage conditions, incorrect use, accidental misuse, abuse, neglect, misapplication or modification, or 
use with non-JRI Maxant' hardware/software. No warranty of fitness for a particular purpose is offered and the user 
assumes the entire risk of using the product. 
In line with our policy of continuous development, we reserve the right to amend our product specification without 
prior notice. 

XXIII.

 

MAINTENANCE CONTRACT 

How to optimize your radio frequency installation? 

RF measuring systems communicate by radio frequency. However, there may be several factors that can modify the 
radio ways already defined, such as moving from a building, adding walls, … Radio frequency requires thus a periodical 
follow up performed by specialists.   
That’s  why  JRI  Maxant  has  created  maintenance  contracts.  We  bring  you  a  global  solution  which  makes  your 
maintenance easier. This overall service offer includes maintenance and also metrological services, which ensure you 
that your system is fully performant. 

You won’t worry about your devices maintenance anymore 

With this maintenance contract you will benefit for a minimal period of 2 years from the following advantages:  

- material verification once or twice a year 
- warranty extension 
- telemaintenance 
- telephone assistance 

+33 (0) 892 680 933 

(0,282 € HT/min)

 

- material replacement on site or by return in our manufacture 
- metrological certificates: verification of measurement accuracy 
- battery change 
- access to new software versions and updates 
- on-site intervention time within 3 open days after problem identification by our experts 

 

XXIV.

 

ENVIRONMENT PROTECTION 

JRI  Maxant  recommends  to  our  customers  to  throw  away  their  measuring  and  recording  devices  which  are 
unserviceable and/or beyond repair in a way that is appropriate to environment protection. Insofar as the production 
of waste cannot be avoided, it is best to re-use them by proceeding with adapted recycling depending on the material 
used and considering the environment protection. 

RoHS Directive 

The  ROHS  European  Directive  rules  and  limits  the  presence  of  hazardous  substances  in  electrical  and  electronic 
equipments (EEE).  
In the article 2, the scope of this Directive excludes "9. Monitoring and Control Instruments" and our products are part 
of this category.  
 

Nevertheless, our company has decided to apply the whole dispositions of this Directive for all our new 
electronic devices which will comply to this 2002/95/CE Directive.  

 

Summary of Contents for Spy RF U

Page 1: ...NOTICE D UTILISATION USER MANUAL Spy RF U 06251F...

Page 2: ...accordement des sondes 6 IV UTILISATION 6 a Arr t 6 b Activation 7 c Attente 7 d Programmation 7 e D marrage des mesures 7 f Mode automatique 7 g Mode manuel 8 h Indication d alarme 8 i Arr t des mesu...

Page 3: ...6VDC 10 A MARQUAGE CE cet appareil est certifi conforme la r glementation europ enne pour la s curit lectrique la inflammabilit l mission de rayonnements perturbants et l immunit aux perturbations le...

Page 4: ...du plafond pour viter les obstacles et les passages de personnes Dans la mesure du possible placer le Spy RF ModeM dans une position centrale par rapport aux points de mesure Essayer de les placer de...

Page 5: ...de diff rentes natures Les capteurs peuvent le cas ch ant tre d connect s de l enregistreur pour leur remplacement ou pour l change de l enregistreur lui m me Mod le 1Voie Mod le 2Voies Support mural...

Page 6: ...odem se reporter la notice de Sirius pour connaitre les configurations minimales requises a Arr t A r ception le SPY RF est l arr t Seule l horloge est active Il ne peut ni mettre ni recevoir Embase m...

Page 7: ...guration du SPY RF est r alis e l aide du Logiciel Sirius voir notice Sirius puis transmise au SPY RF par l interm diare du Spy RF Modem e D marrage des mesures Le SPY RF est muni de 2 modes de d marr...

Page 8: ...alarme Le SPY RF est muni de plusieurs indicateurs simultan s de d passement de seuil Pr alarme Alarme T moin d alarme rouge Clignote toutes les 15 Indicateur de seuil haut ou bas Valeur mesur e clig...

Page 9: ...t AUTO CONTROLE Mode stockage Cette fonction permet de personnaliser une action de v rification des mesures Un appui court sur le BP L action est m moris e et appara tra sur la courbe lors de l exploi...

Page 10: ...arr t des mesures V REMPLACEMENT DE LA PILE Quand la pile du SPY RF doit tre remplac e l afficheur vous le signal par le message suivant Pour remplacer la pile suivre les tapes suivantes VI RESET En c...

Page 11: ...50 C et 0 5 C en dehors Intervalle de mesure 1s 90 min Taille m moire 20 000 mesures Conditions assign e de fonctionnement 30 70 C Temp rature de stockage 40 85 C Port e radio en champ libre 1 km Ban...

Page 12: ...JRI Maxant 12 IX FICHE D APTITUDE L EMPLOI...

Page 13: ...met d assurer le fonctionnement performant de vos appareils ou de votre installation Vous n aurez plus vous soucier de l entretien de vos appareils Ce contrat de maintenance vous permet de b n ficier...

Page 14: ...ring 18 f Connecting probes 18 IV INSTALLATION ERREUR SIGNET NON DEFINI V USE 18 a Stop 18 b Start 19 c Waiting mode 19 d Configuration 19 e Measurement start 19 f Automatic start 19 g Manual start 20...

Page 15: ...6VDC 10 A CE MARKING this equipment is certified to comply with the European regulation for the electric security inflammability disturbing radiation emission and immunity to surrounding electric dist...

Page 16: ...to 40cm from the ceiling to avoid obstacles and moving persons If possible place the Spy RF in central position regarding the Spy RF recorders Try to place them preferably at sight of each other On t...

Page 17: ...ion of different type of probes very easy The probes can otherwise be disconnected from the recorder to be changed or to change the recorder itself 1 channel 2 channels Wall mounting bracket Connector...

Page 18: ...the minimum system requirements a Stop When you receive it your SPY RF is stopped Only the time clock is active It can neither emit nor receive anything Male connector on SPY RF U Female connector on...

Page 19: ...ration is done from the Sirius software see Sirius user manual and then transferred into your SPY RF by radio frequency thanks to a Spy RF ModeM e Measurement start The SPY RF has 2 starting mode auto...

Page 20: ...mber measurement unit and memory status The green LED flashes every minute h Alarm visualisation The SPY RF is equipped with different alarm indicators when a threshold limit is overpassed Pre alarm A...

Page 21: ...mode and AUTO CONTROL Storage mode This function enables you to customise an action of measurement check up You just have to press shortly on the pushbutton The action is recorded and will appear on...

Page 22: ...r To remove stubborn dirt use a soft cloth impregnated with a mild detergent non abrasive Then wipe gently with a soft dry cloth Never use benzene thinners alcohol or solvents of any kind which may ca...

Page 23: ...e EMT 0 20 C from 20 to 50 C and 0 5 C outside Recording interval 1s to 90 min Memory size 20 000 measurements Operating conditions 30 70 C Temperature for storage 40 85 C Radio range in free field 1...

Page 24: ...JRI Maxant 24 XXI CAPACITY OF OPERATION DATA SHEET...

Page 25: ...w up performed by specialists That s why JRI Maxant has created maintenance contracts We bring you a global solution which makes your maintenance easier This overall service offer includes maintenance...

Reviews: