background image

©JRI  

 

IX.

 

WARRANTY 

JRI products carry a one year warranty and guarantee against defects in their components or workmanship. 

During this period if any product supplied by the Company proves on inspection to be defective, the Company will at its own option 

replace the same or refund to the Buyer the price of the product. 

In no circumstances will JRI' liability exceed the price of the product paid by the buyer or the cost of replacement. 

JRI shall not in any event be liable to the Buyer for any indirect or consequential loss or damage costs or expenses whatsoever which 

might arise out of or in connection with the supply of the product or its consequent use. 

Consequently, the products warrantee and guarantee specified above, does not cover damage caused by fair wear and tear, 

abnormal storage conditions, incorrect use, accidental misuse, abuse, neglect, misapplication or modification, or use with non-JRI' 

hardware/software. No warranty of fitness for a particular purpose is offered and the user assumes the entire risk of using the product. 

In line with our policy of continuous development, we reserve the right to amend our product specification without prior notice. 

 

 

X.

 

MAINTENANCE CONTRACT

 

How to optimize your radio frequency installation? 

RF measuring systems communicate by radio frequency. However, there may be several factors that can modify the radio ways 

already defined, such as moving from a building, adding walls, … Radio frequency requires thus a periodical follow up performed by 

specialists.   
That’s why JRI has created maintenance contracts. We bring you a global solution which makes your maintenance easier. This 

overall service offer includes maintenance and also metrological services, which ensure you that your system is fully performant. 

You won’t worry about your devices maintenance anymore 

With this maintenance contract you will benefit for a minimal period of 2 years from the following advantages:  

- material verification once or twice a year 

- warranty extension 

- telemaintenance 
- telephone assistance 

+33 (0) 892 680 933 (0,282 € HT/min)

 

- material replacement on site or by return in our manufacture 

- metrological certificates: verification of measurement accuracy 

- battery change 

- access to new software versions and updates 

- on-site intervention time within 3 open days after problem identification by our experts 

 

XI.

 

ENVIRONMENT PROTECTION

 

JRI recommends to our customers to throw away their measuring and recording devices which are unserviceable and/or beyond 

repair in a way that is appropriate to environment protection. As the production of waste cannot be avoided, it is best to re-use them 

by proceeding with adapted recycling depending on the material used and considering the environment protection. 

RoHS Directive 

The ROHS European Directive rules and limits the presence of hazardous substances in electrical and electronic equipments (EEE).  
In the article 2, the scope of this Directive excludes "9. Monitoring and Control Instruments" and our products are part of this category.  

Nevertheless, our company has decided to apply the whole dispositions of this Directive for all our new electronic devices which will 

comply to this 2002/95/CE Directive.

 

 

Summary of Contents for SPY RF AlarM

Page 1: ...USER MANUAL Spy RF Alarm 06255D ...

Page 2: ...s 3 III PRESENTATION 4 IV INSTALLATION 4 a Installation recommendations 4 b Installation of wall mounting bracket 4 c Activation 4 V BATTERY CHANGE 5 VI RESET 5 VII CHARACTERISTICS 5 VIII ADDING SPY RF ALARM IN SIRIUS 6 a Setting up 7 b Sending remote alarm 7 IX WARRANTY 8 X MAINTENANCE CONTRACT 8 XI ENVIRONMENT PROTECTION 8 ...

Page 3: ...ivered by a main power supply adaptor 230VAC Comply to the security and utilization regulations of electric power Use an electric installation complying with these regulations CE MARKING this equipment is certified to comply with the European regulation for the electric security inflammability disturbing radiation emission and immunity to surrounding electric disturbances FCC ID W45 03330 This dev...

Page 4: ... to avoid obstacles and moving persons If possible place the Spy RF in central position regarding the Spy RF recorders Try to place them preferably at sight of each other On the wall it is preferable to them aside by using the special bracket ref 08512 of the catalog Place the antenna above the top the monitored unit fridge incubator oven cold rooms Never place the Spy RF horizontally If some diff...

Page 5: ...C Storage range 40 85 C Radio range in free field 1km Radio band 868MHz or 902MHz Power supply 9 VDC 300 mA battery life 200 alarms or 2years Dimensions 123x69x30mm Protection degree IP34 EN 12 830 compliance Yes this device must be regularly checked according to EN 13 486 1 time per year recommended CE ERM compliance EN 301 489 EN 61000 EN 61010 EN 55022 EN 300 220 FCC compliance FCC part 15 Supp...

Page 6: ...n N of concerned Spy RF AlarM Type Choose for what sort of alarm Target Monitoring units concerned Time delay Delai before alarm goes on After Ending the window will close and the Spy RF AlarM is installed and appear in the fleet Ajouter un appareil Choose the type of recorder Select the modem associated to the device Enter the serial n of the device End Select the device model ...

Page 7: ...n Sirius to initialize it again 2 contact duration for each state in second 3 activation led and buzzer coefficient Take care changing this setting modifies the duration of battery life It is recommanded to program a planned task reading Spy RF Alarm configuration to check if it is already operational If the device do not answer to the Sirius request Sirius will send a technical alarm b Sending re...

Page 8: ...formed by specialists That s why JRI has created maintenance contracts We bring you a global solution which makes your maintenance easier This overall service offer includes maintenance and also metrological services which ensure you that your system is fully performant You won t worry about your devices maintenance anymore With this maintenance contract you will benefit for a minimal period of 2 ...

Reviews: