background image

NSVS1058 Oct. 2004 

 

 

 

 
Notice 

 

1.  Use this component within operating temperature range. It might not be 

satisfied with electrical specification without operating temperature range. 
When it is used less than -40ºC or more than +85ºC, it might be a cause of 
degradation or destruction of the component. Even if it endures during a short 
time, it causes degradation of qualification. 

 

2.  When soldering iron is used, solder with the temperature at the tip of soldering 

iron: 350ºC max., the time of soldering: 10 seconds max., the power of 
soldering iron: 30W max.. 

 

3.  Notice that the allowed time of soldering with soldering iron is accumulated 

time, when soldering is repeated. 

 

4.  As rapid temperature change for cleaning after reflow soldering might be a 

cause of destruction clean this component after confirming that temperature of 
this component goes down to room temperature. 

 

5.  Confirm that there are not any influence for qualification to this component in 

mounting on PCB when this component is cleaned. 

 

6.  As it might be a cause of degradation of destruction to apply static electricity to 

this component, do not apply static electricity or excessive voltage while 
assembling and measuring. And do not transport this component with bare 
hand. 

 

7.  As it might be a cause of degradation or destruction to apply D.C. voltage 

between each terminal, apply D.C. voltage 7.5V max. in actual circuit. 

 
 

Note 

1.  This specification specifies the quality of this component as a single unit. Make 

sure that this component is evaluated and confirmed against this specification 
when it is mounted to your products. 

 
2.  The information contained herein may be changed without prior notice. It is 

therefore advisable to contact Japan Radio Company before proceeding with the 
design of equipment incorporating this product. 

 

3.

 

The products are designed to be used with ordinary electronic equipment (data 

and communications equipment, office equipment, audio-video equipment, 
measuring instruments, etc). Japan Radio Company does not assume any 
liability for the case using the products with the application required high 
reliability or safety extremely (such as space equipment, sea-bottom equipment, 
medical equipment etc). When intending to use any our product  please 
contact our sales representatives in advance. 

Summary of Contents for NSVS1058

Page 1: ... 1dB Response Variation 1574 42 1576 42MHz 0 8dB max 0 2dB Input and Output VSWR 1574 42 1576 42MHz 1 8 max 1 2 DC 900MHz 35dB min 39dB 1500MHz 35dB min 41dB 1675MHz 18dB min 23dB Out of Band Rejection Relative to Through Level 2000 3000MHz 20dB min 31dB Operating Temperature Range 40 85ºC Table 2 Maximum Ratings Item Rating Maximum Input Power 20dBm Maximum DC Voltage 7 5V Operating Temperature R...

Page 2: ...t Number Month Oct X Nov Y Dec Z Pin no Connection 1 GND 2 IN OUT 3 GND 4 OUT IN Fig 1 Measuring circuit Fig 2 Package dimensions in mm Fig 3 Desirable land area in mm 1 15 1 15 1 03 1 03 2 8 3 3 IN 50Ω OUT 50Ω GR 4X 1 3 2 4 0 6 3 2 5 0 1 2 0 0 1 0 75 0 2 1 0 0 1 4x 2 x 4 x 1 2 ...

Page 3: ...f destruction to apply static electricity to this component do not apply static electricity or excessive voltage while assembling and measuring And do not transport this component with bare hand 7 As it might be a cause of degradation or destruction to apply D C voltage between each terminal apply D C voltage 7 5V max in actual circuit Note 1 This specification specifies the quality of this compon...

Page 4: ...n 200 CH2 center 1575 42 span 200 Insertion Loss dB 1 1 1574 42 MHz 1 07 dB 2 2 1576 42 MHz 1 08 dB 3 3 1500 MHz 63 86 dB 4 4 1675 42 MHz 24 16 dB 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 FREQUENCY CHARACTERISTICS NSVS1058 Oct 2004 S11 S22 S11 S22 1 1 3 3 5 5 7 7 9 9 11 11 1475 4 1475 4 1675 4 1675 4 Frequency MHz Frequency MHz VSWR VSWR InsertionLoss dB 0 10 20 30 40 50 0 3000 S21 Frequency MHz ...

Reviews: