background image

ISO 9001, ISO 14001 Certified

SEP. 2017  Edition 3

CODE No.7ZPRD0955

MARINE RADAR

MARINE RADAR

EQUIPMENT

EQUIPMENT

JMR

JMR-5410

5410-6X/6XH

6X/6XH

JMR

JMR-5425

5425-6XH/7X/9X

6XH/7X/9X

JMR

JMR-5430

5430-S

JMR

JMR-5472

5472-S

JMR

JMR-5482

5482-S/SH

S/SH

Not use the asbestos 

For further information,contact:

URL Head office :  http://www.jrc.co.jp/eng/
Marine Service Department
  1-7-32 Tatsumi, Koto-ku, Tokyo 135-0053, Japan
           : [email protected]
           : +81-50-3786-9201

e-mail
One-call 

SIMPLIFIED

SIMPLIFIED

INSTRUCTION

INSTRUCTION

MANUAL

MANUAL

Summary of Contents for JMR-5410-6X

Page 1: ...425 6XH 7X 9X 6XH 7X 9X JMR JMR 5430 5430 S JMR JMR 5472 5472 S JMR JMR 5482 5482 S SH S SH Not use the asbestos For further information contact URL Head office http www jrc co jp eng Marine Service Department 1 7 32 Tatsumi Koto ku Tokyo 135 0053 Japan tmsc jrc co jp 81 50 3786 9201 e mail One call SIMPLIFIED SIMPLIFIED INSTRUCTION INSTRUCTION MANUAL MANUAL ...

Page 2: ......

Page 3: ... 11 2 9 Switching the Transmission Pulse Length 2 12 2 10 Switching the Azimuth Mode 2 13 2 11 Switching the Motion Mode 2 14 2 11 1 Resetting own ship to its initial position in TM True Motion display mode 2 15 2 12 Displaying Radar Trail 2 16 2 12 1 Changing the trail length 2 16 2 12 2 Erasing a radar trail 2 16 2 12 3 Changing the display mode of radar trails 2 17 Section 3Operation of Target ...

Page 4: ... 1 1 Setting up the vector mode 5 1 5 1 2 Setting up the vector length 5 1 5 2 Setting Up the Collision Determining Condition 5 2 5 2 1 Setting up the CPA limit 5 2 5 2 2 Setting up the TCPA limit 5 2 Section 6 Other Operations 6 1 6 1 Stopping an Alert 6 1 6 2 Acknowledging an Alert 6 2 6 3 Operation with the Software Keyboard 6 3 ...

Page 5: ...er suppression function always perform optimum suppression adjustment About rain snow clutter suppression Do not adjust the rain snow suppression function excessively Otherwise targets such as vessels and dangerous objects will be suppressed in addition to echoes from rain and snow causing to interfere detection When using the rain snow clutter suppression function always perform optimum suppressi...

Page 6: ...Section 1 Introduction 1 2 ...

Page 7: ... Mode Selection screen The RADAR screen appears The preheating time is displayed at the centre of the screen When the magnetron radar antenna is connected Preheat is displayed on the Standby Send switching button 4 Wait until preheating is complete When the preheating time expires the preheating time display disappears and the display of the Standby Transmit switch button changes from Preheat to S...

Page 8: ...ay of the Standby Transmit switch button changes from Transmit to Standby Memo If observation using the radar is being scheduled within a comparably short period of time keep this state Observation can be started immediately by just clicking on the Standby Transmit switch button 2 Press the Power button on the operation unit The power to this equipment is turned OFF Power button Please press the 2...

Page 9: ...tness by using the Light button and Dark button Whenever the Light button Dark button is clicked on the brightness changes by one level 2 3 2 Adjust the screen using the MULTI dial If the MULTI dial is operated while Display Brightness function is selected as the MULTI dial assignment function the Display Brightness dialogue is displayed It is possible to adjust the brightness of the display secti...

Page 10: ...ill enable a wider range to be observed However a video image is small and the ability to detect targets near own ship decreases Therefore when observing the vicinity of own ship use the smaller observation range Decreasing the observation range will enable the vicinity of own ship to be enlarged However caution must be taken because video images of the area beyond the observation range cannot be ...

Page 11: ...urrent reception gain level is indicated by the bar and a numeric value Points on adjustments As reception gain is increased the range in which radar images can be observed widens however if gain is increased too high receiver noise false echoes and other undesired signals will increase on the screen lowering the visibility of targets Also it gets easier to see the screen display if gain is decrea...

Page 12: ...if excessive effect is applied please note that targets having weak signal strength such as buoys and small ships will disappear Using the function of automatic sea clutter suppression mode The sea clutter suppression in accordance with the intensity of sea clutter is possible Use this mode when the sea clutter s intensity differs according to directional orientation 1 Click on the Automatic Sea C...

Page 13: ...23 24 25 APP A APP B 1 Canceling automatic sea clutter suppression 1 Click on the Automatic Sea Clutter Suppression button MAN manual is displayed on the automatic sea clutter suppression button Each time this button is clicked on the display switches between AUTO automatic and MAN manual ...

Page 14: ...ases the amount of images by rain snow clutter The current level of rain snow clutter suppression is indicated by the bar and a numeric value Points on adjustments When the amount of images by rain snow clutter is decreased the outlines of targets hidden by images of rain snow will appear but please note that small targets may be missed Since this can also reduce sea clutter it is effective to use...

Page 15: ...utton is clicked on the display switches between AUTO automatic and MAN manual 2 Click the left mouse button of the button on the Rain rain snow clutter adjustment slider drag it with the trackball and adjust the volume of the echo created by rain snow clutter that is displayed on the screen Even while auto rain snow clutter is being suppressed the amount of images can be fine adjusted manually Ca...

Page 16: ...ion status must be Transmit 1 Enable the manipulation of EBL1 by clicking on the EBL1 button 2 Enable the movement of EBL1 by clicking on the EBL1 line 3 Align the cursor with a target and click on the mouse button The bearing of the target is displayed on the EBL1 button 4 Enable the manipulation of VRM1 by clicking on the VRM1 button 5 Enable the movement of VRM1 by clicking on the VRM1 circle 6...

Page 17: ...on the EBL2 line 4 Align the cursor with bearing point B of the two points to be measured and then click it on 5 Enable the manipulation of VRM2 by clicking on the VRM2 button 6 Move the intersecting point marker on the dotted line of EBL2 by the cursor and align it with point B The range and bearing between the two points are displayed Memo The measurement reference point of this equipment s EBL ...

Page 18: ...proves The effect of suppressing sea clutter and rain snow clutter improves In bays harbors where targets are densely crowded Rough sea state due to torrential rain or stormy weather MP The normal transmitter pulse length is set Both range resolution and gain are appropriately set General navigation LP The transmitter pulse becomes longer and gain improves Small targets are zoomed and are easy to ...

Page 19: ... mode is suitable for watching over other ships This is not available for TM True Motion mode C UP Course UP Course Up At the setting of Course Up the ship s heading HDG is fixed and displayed immediately above the screen Similar to true bearing display the positions of stationary targets will not deviate even if yawing occurs in the ship targets are displayed stably and the bearing of the heading...

Page 20: ...g relative motion RM mode to true motion TM mode 1 Click on the Motion Mode combo box in Range and mode information 2 Select the motion mode Memo Available combinations vary depending on the settings of the motion mode and the azimuth mode refer to 2 10 Switching the Azimuth Mode Azimuth mode Motion mode N UP H UP C UP C UP Angle Setting TM RM T or RM R Motion Mode combo box ...

Page 21: ...according to the own ship s speed course and influence of the tidal current When the own ship s position reaches the position of about 60 of the screen radius the position is reset to the position of about 66 of the screen radius in the direction opposite to the own ship s course COG by adding the influence of the tidal current at that time RM T or RM R Relative Motion Mode Relative Motion display...

Page 22: ...ngth Short mode Off 15 sec 30 sec 1 min 3 min 6 min 10 min 15 min 30 min 60 min Long mode Off 30 min 1 hr 2 to 24 hrs at 1 hr interval from 1 to 24 hrs 2 12 2 Erasing a radar trail 1 Click on the CLR clear trails button The confirmation dialogue box appears 2 Click on the OK button All the saved trails data will be cleared The system starts plotting trails in initial state CLR clear trails button ...

Page 23: ... trail motion modes vary depending of the motion mode that is set True motion display TM Only true motion trail is available Relative motion display RM Relative motion trail and true motion trail can be selected RM T is displayed when relative motion trail is used RM R is displayed when true motion trail is used 1 Click on the Trails True Relative switch button Each time this button is clicked on ...

Page 24: ...Section 2 Basic Operation 2 18 ...

Page 25: ...ate in which the number of targets being tracked has reached the maximum number of targets the target with the lowest danger level among the targets that have been captured thus far automatically is erased successively When all the targets that are tracked are for manual acquisition and the number has reached the maximum number of targets no further acquisition is allowed Operation procedure Open ...

Page 26: ...t is located less than 0 1 NM from own ship To acquire the tracked target in the manual acquisition mode 1 Set the cursor mode to the AUTO mode 2 Place the cursor on the target to be acquired and then click on The target is acquired and the initial acquisition symbol is displayed The vector is displayed within 1 minute 3 1 3 Using manual acquisition and auto acquisition together By using manual ac...

Page 27: ...get is displayed in the information monitoring window The symbol display is changed to The target data will remain on the radar display until the target is lost and its vector disappears or until another target is designated If a target with the mark is designated only its true bearing and range appear until its vector appears Cancellation of numeric data display 1 Set the cursor mode to the AUTO ...

Page 28: ...ight click The context menu is displayed 2 Click on the Cancel TT mode on the Context menu The cursor changes to the selection cursor 3 Place the cursor on another target to be cancelled and then click on 4 Repeat the operation in step 3 The vector symbols of the clicked tracked targets disappear and only the radar image remains Finish the cancel TT mode by clicking the right mouse button To erase...

Page 29: ...APP A APP B 1 Section 4 AIS Operation 4 1 Setting Up the AIS Display Function 1 Click on the AIS button for other ship information on the upper right of PPI The button indication becomes ON and the AIS function becomes enabled ON indication The received AIS information is displayed on the screen ...

Page 30: ...activation Activate an AIS target in automatic mode to display the vector and heading line When the automatic activation function is used AIS targets are automatically activated when they go into the automatic activation zone The automatic activation zone is identical to the automatic acquisition zone AZ used for target tracking For the zone setting refer to 3 1 1 Auto acquisition automatic acquis...

Page 31: ...ormation and then click on The information of the selected AIS target is displayed Memo When the numeric data of a target is displayed but the mark is not on the radar display the target is outside the display Canceling AIS target information display 1 Set the cursor mode to the AUTO mode 2 Move the cursor to and click on the activated AIS target whose AIS target information is to be cancelled The...

Page 32: ...are displayed 2 Click on the Deactivate on the Context menu The selected AIS target is deactivated Deactivating multiple AIS targets 1 Right click on the AIS target The setting items for cursor modes are displayed 2 Click on Deactivate mode on the Context menu The cursor changes to the selection cursor 3 Click on the AIS target to be deactivated The selected AIS target is deactivated Memo This ope...

Page 33: ...ng up the vector mode 1 Click on the trail true relative selector button in the other ship information window Each click switches track display mode between T and R 5 1 2 Setting up the vector length The Vector Length is set in min in the range from 1 min to 120 min 1 Click on the Vector Length input box in the other ship information window 2 Enter the Vector Length Vector Length input box Trail t...

Page 34: ...it value input box in the other ship information window Set the CPA limit in the unit of 0 1 NM within the range from 0 1 NM to 9 9 NM 2 Enter the CPA limit 5 2 2 Setting up the TCPA limit 1 Click on the TCPA limit value input box in the other ship information window Set the TCPA limit in the unit of 1 min within the range from 1 min to 99 min 2 Enter the TCPA limit TCPA limit value input box CPA ...

Page 35: ...1 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 Section 6 Other Operations 6 1 Stopping an Alert To stop a buzzer silencing click the silence button in the alert notification area or press the SILENCE key in the operation unit SILENCE key Silence button ...

Page 36: ...wledgement key of the operation section is pressed after verification of the alert contents the alert that is currently displayed is acknowledged When there are multiple alerts perform the same operation by displaying the details dialogue box of another alert When all the alerts are acknowledged the alert detail display dialogue is closed automatically ACK button ALERT ACK key ...

Page 37: ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 6 3 Operation with the Software Keyboard 1 Click the numeric key you want to enter 2 Verify that the value you specified is correct and then click the Enter key The entry is accepted ...

Page 38: ...Section 6 Other Operations 6 4 ...

Page 39: ......

Page 40: ...425 6XH 7X 9X 6XH 7X 9X JMR JMR 5430 5430 S JMR JMR 5472 5472 S JMR JMR 5482 5482 S SH S SH Not use the asbestos For further information contact URL Head office http www jrc co jp eng Marine Service Department 1 7 32 Tatsumi Koto ku Tokyo 135 0053 Japan tmsc jrc co jp 81 50 3786 9201 e mail One call SIMPLIFIED SIMPLIFIED INSTRUCTION INSTRUCTION MANUAL MANUAL ...

Reviews: