2
-
30
JMA-9100/7100 Installation Manual > 2.INSTALLATION OF SCANNER UNIT > 2.4 PRECAUTIONS
3)
Permissible bending radius
•
The permissible bending radius R of flexible waveguide is 200mm/400mm (E-bent/H-
bent). More sharp bending with less radius than this must be avoided.
•
The permissible bending radius R of coaxial cable is 350mm. More sharp bending with
less radius than this must be avoided.
Fig 2-20:
The permissible bending radius of flexible waveguide
Fig 2-21:
The permissible bending radius of coaxial cable
R=200mm(MIN)
R=400mm(MIN)
(a) E-bent
E
面曲げ半径
(b) H-bent
H
面曲げ半径