JMA-5300 SPECIFICATIONS
Model
Display format
Range scale
Raster scann PPI format
0.125
/
0.25
/
0.5
/
0.75
/
1.5
/
3
/
6
/
12
/
24
/
48
/
96
(
120
)
nm
Microwave IC (Mic)
Automatic
Temperature: -25
〜
+55
°
C, Humidity: 93% @40
°
C
NDC-1273
Head-up / North-up / Course-up
Relative motion(RM)with True trail / Relative motion(RM)with Relative trail / True motion
2-line/Bearing: 000.0-359.9
°
(4-digit)
2-marker/Scale: 0.000-96.0 (or 120.0) NM (4-digit)
off / 15sec / 30sec / 1min / 3min / 6min / 10min / 15min / 30min / 60min / continuous
C-MAP
NWZ-147
18.1inch color 1280
×
1024 dots (SXGA)
more than 250mm
5m (between the processor and the display unit)
NCE-7699
5m (between the processor and the operation unit)
Temperature: -15
〜
+55
°
C, Humidity: 93% @40
°
C, water-proof: IPX2
NCT-59 (built-in Processor unit)
NCA-877W (built-in Processor unit)
NCA-877 (built-in Processor unit)
NQE-3141-4 (Max.4 radars)
NQA-4250 (built-in Processor unit)
NDB-34 (built-in Processor unit)
NBA-3308 (100 / 110 / 115 / 200 /230 Vac)
DC24V (DC21.6
〜
31.2V
)
AC230V(
±
10%)50/60Hz
1
φ
※
1
NKE-1075A
12ft
30kW
3050
±
10MHz
H: 1.9
°
, V: 30
°
Approx 26 / 21rpm(60/50Hz)
0.07uS / 1900Hz,
0.20uS / 1900Hz
,
0.3uS / 1900Hz
,
0.6uS / 1100Hz
,
1.2uS / 570Hz
CirTRHPL
NQE-3151
Model
Scanner
Output
Transmiting frequency
Polarization characteriting
(-3dB width)
Rotation speed
Transmitter / receiver switching
Frequency conversion
Tuning
Environment
Model
Screen display
Motion mode
EBL
VRM
Course display
Chart display
Model
LCD
Valid diameter
Installation cable
Model
Installation cable
Model
NSK Unit
ARPA unit -Professional version-
※
2
ATA unit -Common version-
※
2
Performance monitor
※
2
Inter-swich box
AIS Interface unit
Plotting Function unit
AC Rectifier
Environment
Circulater diode
Pulse width
Scanner
Display
Option
Installation cable
Power consumption
Average 200W, Maximum 300W
Input voltage (Voltage range)
DC24V (DC21.6
〜31.2V)
CFQ-6912-20 (Standard 20m)
CFQ-6912-5 (Standerd 5m)
2695110056 (Standerd 20m)
Average 150W,
Maximum 300w
Average 150W+200VA
Maximum 150W+3kVA
Processor
Display unit
Operation unit
Connection box
JMA-5320-7
JMA-5310-6
JMA-5320-9
JMA-5330-12
NKE-2252-9
9ft
25kW
H: 0.8
°
, V: 20
°
NKE-2102-6
6ft
10kW
H: 1.2
°
, V: 20
°
Approx 24rpm
0.08uS / 2250Hz
,
0.25uS / 1700Hz,
0.5uS / 1200Hz,
0.8uS / 750Hz,
1.0uS / 650Hz
NKE-2252-7
7ft
25kW
9410
±
30MHz
H: 1.0
°
, V: 20
°
Approx 24rpm
0.08uS / 2200Hz
,
0.20uS / 2200Hz,
0.4uS / 1400Hz, 0.8uS / 750Hz, 1.0uS / 650Hz
NJU-64
NJU-63
For further information, contact:
Since 1915
Printed in Japan
2004.10
'04.10
CAT.No.Y9-162(No.646-1-5)A
Main Office:
Nittochi Nishi-Shinjuku bldg.
10-1, Nishi-Shinjuku 6-chome
Shinjuku-ku, Tokyo 160-8328, Japan
Telephone: +81-3-3348-4099
Facsimile: +81-3-3348-4139
Overseas Branches : Seattle, Amsterdam
Liaison Offices : Taipei, Manila, Jakarta, Singapore,
Hanoi, New York, Athens
24EM
ISO
9001
,
ISO
14001 Certified
URL
●
Read the Instruction Manual before your use for safety in operation.
●
Do not install this equipment in a place with water, wetness, vapor, dust and oily smoke. Otherwise, a fire, electric shock or failure may result.
●
For the installation work for this equipment, request to JRC agents or dealers. The installation work done by any non-specialist personnel
may result in an electric shock or failure.
●
The specification and appearance of the equipment may be subject to change without notice.
CAUTION
※
1
:
For the scanner of JMA-5330-12, AC power source is needed for the motar of scanner.
※
2
:
For compliance with IMO reqwement, ARPA or ATA unit, and performance monitor are needed.
Summary of Contents for JMA-5300 Series