Chapter 3 Operation
35
3.1.2 Operation of each unit for every alarm
Normal
state
Visual
Indication
1st stage
Bridge
audible
alarm
2nd stage
remote
audible
alarm
3rd stage
remote
audible
alarm
Bridge
(LCD display unit NWZ-4650)
Illuminated Blinking
Blinking
Blinking
Blinking
Bridge
(LED warning lamp unit NCD-2257)
-
Blinking
Blinking
Blinking
Blinking
Bridge
(Reset button unit NCJ-895 / 896)
Illuminated Blinking
Blinking/
Sounding
Blinking/
Sounding
Blinking/
Sounding
Backup Officer
(Buzzer unit NVS-785)
-
-
-
Sounding
Sounding
Officer
(Buzzer unit NVS-785)
-
-
-
-
Sounding
Public room
(Buzzer unit NVS-785)
-
-
-
-
Sounding