32 | Operation
2.5.1.2 Touch Screen Calibration (TOUCH CAL)
The touch screen can be calibrated by following the instructions that appear on the screen.
Figure 23: Touch Screen Calibration
Menu
Figure 24: Calibration Reference
Points
Figure 25: Calibration Lines
1. In the MENU, touch the TOUCH CAL button.
The TOUCH SCREEN CALIBRATION MENU appears, see Figure 23: Touch Screen Calibration Menu on page
32.
2. Calibrate the screen by touching the CONFIRM CALIBRATE THE TOUCH SCREEN button.
The calibration screen appears with text requesting to touch the four numbered reference points that appear on the
screen, see Figure 24: Calibration Reference Points on page 32.
3. Touch the four reference points in sequence 1 to 4, as they light up.
The application will determine whether the sequence is carried out correctly.
4. If the text VALID CALIBRATION appears, then the calibration is performed accurately. Test calibration for accuracy
by dragging a finger across the screen, see Figure 25: Calibration Lines on page 32.
The line that appears on the screen should follow the finger.
5. Touch the ACCEPT button if calibration appears to be correct, or touch the AGAIN button to repeat the calibration
process.
6. If the text INVALID CALIBRATION...PLEASE RETRY appears, touch the AGAIN button to repeat the calibration
process.
Summary of Contents for AlphaWind AlphaLine MFL
Page 1: ...AlphaWind Wind Repeater Installation and Operation Manual www jrc am ...
Page 29: ...29 Operation Figure 21 Alert Handling in Menu example ...
Page 57: ...57 Appendix A 4 3 2 Mechanical Drawing MFL Figure 52 Mechanical Drawing MFL ...
Page 59: ...59 Appendix A 4 4 2 Connection Diagram AlphaWind Figure 54 Connection Diagram AlphaWind 1 ...
Page 60: ...60 Appendix A Figure 55 Connection Diagram AlphaWind 2 ...
Page 63: ...63 Appendix A 4 5 2 Schematics AlphaLine Instrument Figure 57 Schematics AlphaLine Instrument ...