JP Fluid Control ST-SB Series Manual Download Page 5

JP FLUID CONTROL

 

MANUAL-ST-SB-EN v1.2                                                              www.jpfluidcontrol.com                                                                                   5 

ST-SB SERIES 

SOLENOID VALVES 

1

2

3

1

2

3

 

 

 

 

 

 

Connector: EN 175301-803 (formerly DIN 43650A). 

The poles (1) and (2) should be connected to the power supply, polarity i s 

not important. Pole (3) is connected to the ground. Connect the connector 

thoroughly to avoid ingress of moisture. Ensure that drops cannot slip 

along the cable and enter the connector .

 

4.

 

SPARE PARTS 

The wear parts of the solenoid valve can  be replaced with a repair kit 
(plunger, plunger spring, membrane, membrane spring, O-ring). 

Product code 

Seal 

Body 

ST-SB-N-REV 

NBR 

Brass  
(orifice 10.5 mm) 

ST-SB-E-REV 

EPDM 

ST-SB-F-REV 

FKM 

ST-SB-SN-REV 

NBR 

Stainless Steel 
(orifice 9 mm) 

ST-SB-SE-REV 

EPDM 

ST-SB-SF-REV 

FKM 

 

The product code of the coil is as follows: 

Product code 

Voltage 

CS2-380AC 

380V AC 50Hz 

CS2-230AC 

230V AC 50Hz 

CS2-120AC 

120V AC 60Hz 

CS2-024AC 

24V AC 50Hz 

CS2-024DC 

24V DC 

CS2-012DC 

12V DC 

 
Follow  the  drawing  in  1.7  for  the  correct  assembly  of  the  solenoid 
valve.  

5.

 

DISPOSAL 

The  removal  of  the  product  should  be  performed  in  accordance  with 
the applicable laws. Keep in mind the media that are still present in the 
valve. 

 

This manual can be downloaded from www.jpfluidcontrol.com

 

Modifications reserved       

 

             © JP Fluid Control 

This document has been prepared with great care. JP Fluid control assumes no responsibility for any errors that may appear in this document. No rights can be derived from this document

 

Summary of Contents for ST-SB Series

Page 1: ...t S Position Normally open B Body Material Brass B SS 316 S Seal Media Temperature NBR N 10 80 C EPDM E 30 130 C FKM F 10 120 C Thread BSPP NPT N Ambient Temperature Max 50 C Min Press Difference 0 bar Max Pressure 16 10 bar AC DC Coil series CS2 Voltage 380V AC 50Hz 380AC 230V AC 50 60Hz 230AC 120V AC 50Hz 120AC 24V AC 50 60Hz 024AC 24V DC 024DC 12V DC 012DC Response Time 50 ms 400 ms Open Close ...

Page 2: ... for aggressive media and corrosive media like seawater Diaphragm The ST SB series is available with several materials In the following table a concise overview is presented of compatible media Depending on the application the correct diaphragm should be selected Diaphragm Temperature Allowed media Not allowed FKM 10 C 120 C Most fuels and oils cold water detergents compressed air Glycol based bra...

Page 3: ...indicated on the product and or in the technical documentation The temperature of a solenoid valve coil can rise during operation this is normal Overheating will cause smoke and a burning smell In this case the power supply must immediately be disconnected Warning a valve opens and closes quickly Improper use can cause pressure transients fluid hammer in the pipes with possible damage as a consequ...

Page 4: ... is mounted at an angle it is recommended to deviate maximally 90 from the vertical position Maximum angle 90 IN OUT Check the flow direction with the help of the indications on the valve body Only exert force at the designated faces never at the coil or armature Installation of the coil Make sure the coil is labeled with the valve characteristics The device can be damaged by the use of unsuitable...

Page 5: ... E REV EPDM ST SB F REV FKM ST SB SN REV NBR Stainless Steel orifice 9 mm ST SB SE REV EPDM ST SB SF REV FKM The product code of the coil is as follows Product code Voltage CS2 380AC 380V AC 50Hz CS2 230AC 230V AC 50Hz CS2 120AC 120V AC 60Hz CS2 024AC 24V AC 50Hz CS2 024DC 24V DC CS2 012DC 12V DC Follow the drawing in 1 7 for the correct assembly of the solenoid valve 5 DISPOSAL The removal of the...