JP FLUID CONTROL
MANUAL-ST-SB-EN v1.2 www.jpfluidcontrol.com 5
ST-SB SERIES
SOLENOID VALVES
1
2
3
1
2
3
Connector: EN 175301-803 (formerly DIN 43650A).
The poles (1) and (2) should be connected to the power supply, polarity i s
not important. Pole (3) is connected to the ground. Connect the connector
thoroughly to avoid ingress of moisture. Ensure that drops cannot slip
along the cable and enter the connector .
4.
SPARE PARTS
The wear parts of the solenoid valve can be replaced with a repair kit
(plunger, plunger spring, membrane, membrane spring, O-ring).
Product code
Seal
Body
ST-SB-N-REV
NBR
Brass
(orifice 10.5 mm)
ST-SB-E-REV
EPDM
ST-SB-F-REV
FKM
ST-SB-SN-REV
NBR
Stainless Steel
(orifice 9 mm)
ST-SB-SE-REV
EPDM
ST-SB-SF-REV
FKM
The product code of the coil is as follows:
Product code
Voltage
CS2-380AC
380V AC 50Hz
CS2-230AC
230V AC 50Hz
CS2-120AC
120V AC 60Hz
CS2-024AC
24V AC 50Hz
CS2-024DC
24V DC
CS2-012DC
12V DC
Follow the drawing in 1.7 for the correct assembly of the solenoid
valve.
5.
DISPOSAL
The removal of the product should be performed in accordance with
the applicable laws. Keep in mind the media that are still present in the
valve.
This manual can be downloaded from www.jpfluidcontrol.com
Modifications reserved
© JP Fluid Control
This document has been prepared with great care. JP Fluid control assumes no responsibility for any errors that may appear in this document. No rights can be derived from this document