JOYTECH HNK-ECT-1 Owner'S Manual Download Page 3

124mm

3

2

0

m

m

 

 BATTERY REPLACEMENT

1.  Replace battery when

appears in the lower right corner of LCD display.

2.  Pull battery cover off as shown in Figure 3.
3.  Gently pull out plastic circuit board with battery chamber approximately 1 cm (slightly less than1/2

 

     (See Figure 4)
4.  Use pointed object such as a pen to remove old battery.  Discard battery lawfully.  Replace with new 
     1.5V DC button type LR41 or SR41,UCC392, or equivalent.  Be sure battery is installed with 

polarity facing up.  (See Figure 5)

5.  Slide battery chamber back into place and attach cover.

      

".)

+

     

LIMITED WARRANTY

Figure 4

Figure 5

Figure 3

0197

Shanghai International Holding Corp.GmbH(Europe)
Eiffestrasse 80, 20537 Hamburg, Germany

EC

REP

Disposal of this product and used batteries should be carried out 
in accordance with the national regulations for the disposal of 
electronic products.

The product is in compliance with the requirements 
of MDD 93/42/EEC, "0197" is the identification 
number of notify body.

Document No.: JDMT-0104-008
Article No.: 001
Version: Z
Date of Issue: 2015.12

CLEANING AND DISINFECTION

Wipe the thermometer with a soft clean cloth.
For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or a
neutral detergent solution and then wring thoroughly. Finish by wiping with a soft dry cloth.
For disinfection, 75% Ethanol or Isopropyl alcohol can be used.
Observe the following to prevent damage to the thermometer.
-Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer.
-Do not attempt to disinfect the sensing section (tip) of the thermometer by immersing in 
  alcohol or in hot water (water over 5

0℃

(122

))

.

-Do not use ultrasonic washing to clean the thermometer.

PRECAUTION

* The performance of the device may be degraded should one or more of the following occur:

    Operation outside the manufacturer s s tated te mperature a nd h umidity r ange.

    Storage outside the manufacturer s s tated te mperature a nd h umidity r ange.

    Mechanical shock (for example, drop test) 

    Patient temperature is below ambient temperature.
* Portable and mobile RF communications can affect the device. The device needs special pre-cautions
   regarding EMC according to the EMC information provided in the accompany documents.

or degraded sensor.

DIGITAL THERMOMETER

This digital thermometer provides a quick and highly accurate reading of an individual's body
temperature. The digital thermometer  is intended to measure the human body’s temperature in 
regular mode orally, rectally or under the arm, and the device is reusable for clinical or home 
use on people of all ages. To better understand its functions and to provide years of dependable 
results, please read all instructions first.
This appliance conforms to the following standards:
EN 12470-3 Clinical thermometers —Part 3: Performance of compact electrical thermometers 
(non-predictive and predictive) with maximum device,
ISO 80601-2-56 Medical electrical equipment —Part 2-56:Particular requirements for basic safety 
and essential performance of clinical thermometers for body temperature measurement,
EN 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and
essential performance – Collateral Standard: Requirements for medical electrical equipment and 
medical electrical systems used in the home healthcare environment and complies with the 
requirements of EN 60601-1-2(EMC), IEC/EN60601-1(Safety) standards. And the manufacturer 
is ISO 13485 certified.

 

PLEASE  READ  CAREFULLY  BEFORE  USING

Battery Cap

On/Off

  Button

LCD

Probe

PRODUCT  ILLUSTRATION

CONTENTS

Figure 1 

OWNER S M

   ANUAL

1 Thermometer,  1 Owner s Manual,  1 Storage Case

SPECIFICATIONS

SYMBOL EXPLANATION

Warning : 

 

Read instructions thoroughly before using digital thermometer.
Choking Hazard:  Thermometer cap and battery may be fatal if swallowed.  Do not allow children
to use this device without parental supervision.
Do not use thermometer in ear.  Designed use is for oral, rectal, and armpit (axilla) readings only.
Do not place thermometer battery near extreme heat as it may explode.

Remove battery from the device when not in operation for a long time.

  

Note: Use of the probe cover may result in a 0.1

(0.2

) discrepancy from actual temperature.

The  use of temperature readings for self-diagnosis is dangerous.  Consult your doctor for the
interpretation of results. Self-diagnosis may lead to the worsening of existing disease conditions.
Do not attempt measurements when the thermometer is wet as inaccurate readings may  result.
Do not bite the thermometer. Doing so may lead to breakage and/or injury.
Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.
After each use, disinfect the thermometer especially in case the device is used by more than one person.
Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is
present. Failure to do so may lead to injury.
Do not use thermometer orally after being used rectally.
For children who are two years old or younger, please do not use the devices orally.
If the unit has been stored at temperatures over 5

℃~

40

(41

℉~

104

℉)

, leave it in 5

℃~

40

(41

℉~

104

℉)

 ambient temperature for about 15 minutes before using it.  

 Direct Current 

 Type BF  Applied Part

Batch Code

Manufacturer

Consult Accompanying Documents

Storage and Transportation 
Temperature Limit: -20

~55

(-4

℉ ~

131

℉)

-20

55

EC

REP

European Authorized Representative

Measure Range:

Ambient operating range:

Storage and transportation
condition: 

32.0

℃-

42.9

(90.0

-109.9

)( 

 /

  chosen by manufacturer)

±

0.1

(

±

0.2

) during 35.5

~42.0

(95.9

~107.6

) at

18

~28

 (64.4

~82.4

 ) ambient operating range

±

0.2

(

±

0.4

) for other measuring and ambient operating range

Liquid crystal display, 3 1/2 digits
For storing the last measured value
One 1.5 V DC. button battery (size LR41or SR41, UCC 392)
Approx. 200hours of continuous operation or 1 year with 3 
measurements per day
12.3cm x 1.8cm x 0.9cm (L x W x H)
Approx. 10 grams including battery

Temperature: 

(

)

5

℃~

40

41

℉~

104

Relative humidity: 15%~95%RH
Atmospheric Pressure : 700hPa ~ 1060hPa

Temperature: 

(

)

-20

~55

-4

℉~

131

Relative humidity: 15%~95%RH
Atmospheric Pressure : 700hPa ~ 1060hPa

Classification:

Type:

Digital Thermometer (Not Predictive)

Type BF

Direct Mode

Ingress Protection Rating: 

IP 22

Accuracy:

Operating mode:                        
Display:
Memory:
Battery:

Battery life:

Dimension:
Weight:

Expected service life:                Three years

DIRECTIONS

2.  Position thermometer in desired location (mouth, rectum, or armpit.)  
     a)  

Oral Use:

  Place thermometer under tongue as indicated by

           position shown in Figure 2.  Close your mouth and breathe evenly 
           through the nose to prevent the measurement from being influenced 
           by inhaled/exhaled air. Normal temperature between 35.7

 and 37.3

           (96.3

 and 99.1

).

     b)  

Rectal Use:

  Lubricate silver probe tip with petroleum jelly for easy insertion.  Gently insert 

           sensor approximately 1cm (less than 1/2  ) into rectum.  Normal temperature between 36.2
           and 37.7

 (97.2

 and 99.9

).

     c)  

Armpit Use: 

 Wipe armpit dry.  Place probe in armpit and keep arm pressed firmly at side.  

          From a medical viewpoint, this method will always provide inaccurate readings, and should not 
          be used if precise measurements are required. Normal temperature between 35.2

 and 36.7

         (95.4

 and 98.1

).

3.  The degree sign flashes throughout the testing process.  When flashing stops an alarm will beep for 
     approximately 10 seconds.  The measured reading will appear on the LCD simultaneously. The 
     minimum measurement time until the signaling tone (beep) must be maintained without exception. The 
     measurement continues even after the buzzer notification. 

4.  To prolong battery life, press the 

On/Off

  Button to turn unit off after testing is complete.  If no action 

      is taken, the unit will automatically shut off after around10 minutes.

“√”

"

So that in order to achieve better body 

     temperature measurement result, recommend to keep the probe in mouth and rectum about 2 minutes, 
     or in armpit about 5 minutes regardless of the beep sound and at least 30 seconds measurement interval
     should be maintained.

*Note:  Normally 

Alarm b eeps m ore ra pidly w hen te mperature  

              reaches 37.8

 (100

) or higher ,and t

              

the buzzes are

 Bi

-

Bi

-

Bi

-

B

   i

-

;   

he  buzzes are

 Bi-Bi-Bi----- Bi-Bi-Bi------- Bi-Bi-Bi

     followed by last recorded temperature. After showing the self-test temperature, the thermometer is 
     now in the testing mode.

1.  Press the

 

On/Off  

Button next to LCD display.  A tone will sound as the screen shows              , 

Figure 2

TROUBLESHOOTING

Problem

Solution

Error message              

The system is not 
functioning properly.

Unload the battery, wait for 1 minute and repower
it. If the message reappears, contact the retailer 
for service.

Temperature taken is
lower than 32.0°C(90.0°F)

Turn off, wait one minute and take a new temperature
 via close contact and sufficient rest.

Temperature taken is 
higher than 42.9°C(109.9°F)

Dead battery: Battery icon is 
flashing, can’t be measurable.

Replace the battery.

Turn off, wait one minute and take a new temperature
 via close contact and sufficient rest.

CALIBRATION

The thermometer is initially calibrated at the time of manufacture. If the thermometer is used according to 
the use instruction, periodic readjustment is not required. However, we recommend checking calibration 
every two years or whenever clinical accuracy of the thermometer is in question. Turn on the thermometer
and insert into the water bath and then check the laboratory accuracy of thermometer. Please send the
complete device to the dealers or manufacturer. 
The above recommendations do not supersede the legal requirements. The user must always comply with 
legal requirements for the control of the measurement, functionality, and accuracy of the device which 
are required by the scope of relevant laws, directives or ordinances where the device is used.

M

JOYTECH HEALTHCARE  CO.LTD.
No.365, Wuzhou Road, Yuhang Economic Development Zone, Hangzhou city, 311100 Zhejiang,China

 

 

 

 

 

 

                   

A

kçeşme Mah. 2019 Sk. No:5 Merkezefendi DENİZLİ / TÜRKİYE 

  

                  

T

el: +90 258 371 46 56  

 

 

 

  

                 

ww.hunkarmedikal.com  

 

 

 

 

                 

 

Hünkar Ecza ve Medikal San. Ve Tic. Ltd. Şti   

 

 

                  

 

Importer  
 

M

odel:

HNK-ECT-1

The thermometer  is  guaranteed for 

two

 year  from the date of  purchase. If  the  thermometer does  not 

function  properly due to defective components or poor workmanship, we will repair or replace it  free of
charge.  All components are covered by this warranty excluding the battery. The warranty does not  cover 
damages  to your thermometer due to improper handling.  

To obtain warranty service, an original or copy 

of the sales receipt from the original retailer is required.

Reviews: