BATTERY REPLACEMENT
1. Replace battery when
appears in the lower right corner of LCD display.
2. Pull battery cover off as shown in Figure 3.
3. Gently pull out plastic circuit board with battery chamber approximately 1 cm (slightly less than1/2
(See Figure 4)
4. Use pointed object such as a pen to remove old battery. Discard battery lawfully. Replace with new
1.5V DC button type LR41 or SR41,UCC392, or equivalent. Be sure battery is installed with
polarity facing up. (See Figure 5)
5. Slide battery chamber back into place and attach cover.
“
”
".)
“
+
”
LIMITED WARRANTY
Figure 4
Figure 5
Figure 3
0197
Shanghai International Holding Corp.GmbH(Europe)
Eiffestrasse 80, 20537 Hamburg, Germany
EC
REP
Disposal of this product and used batteries should be carried out
in accordance with the national regulations for the disposal of
electronic products.
The product is in compliance with the requirements
of MDD 93/42/EEC, "0197" is the identification
number of notify body.
Document No.: JDMT-0104-008
Article No.: 001
Version: Z
Date of Issue: 2015.12
CLEANING AND DISINFECTION
Wipe the thermometer with a soft clean cloth.
For stubborn stains, wipe the thermometer with a cloth that has been dampened with water or a
neutral detergent solution and then wring thoroughly. Finish by wiping with a soft dry cloth.
For disinfection, 75% Ethanol or Isopropyl alcohol can be used.
Observe the following to prevent damage to the thermometer.
-Do not use benzene, thinner, gasoline or other strong solvents to clean the thermometer.
-Do not attempt to disinfect the sensing section (tip) of the thermometer by immersing in
alcohol or in hot water (water over 5
0℃
(122
℉
))
.
-Do not use ultrasonic washing to clean the thermometer.
PRECAUTION
* The performance of the device may be degraded should one or more of the following occur:
Operation outside the manufacturer s s tated te mperature a nd h umidity r ange.
Storage outside the manufacturer s s tated te mperature a nd h umidity r ange.
Mechanical shock (for example, drop test)
Patient temperature is below ambient temperature.
* Portable and mobile RF communications can affect the device. The device needs special pre-cautions
regarding EMC according to the EMC information provided in the accompany documents.
-
’
-
’
-
or degraded sensor.
-
DIGITAL THERMOMETER
This digital thermometer provides a quick and highly accurate reading of an individual's body
temperature. The digital thermometer is intended to measure the human body’s temperature in
regular mode orally, rectally or under the arm, and the device is reusable for clinical or home
use on people of all ages. To better understand its functions and to provide years of dependable
results, please read all instructions first.
This appliance conforms to the following standards:
EN 12470-3 Clinical thermometers —Part 3: Performance of compact electrical thermometers
(non-predictive and predictive) with maximum device,
ISO 80601-2-56 Medical electrical equipment —Part 2-56:Particular requirements for basic safety
and essential performance of clinical thermometers for body temperature measurement,
EN 60601-1-11 Medical electrical equipment —Part 1-11: General requirements for basic safety and
essential performance – Collateral Standard: Requirements for medical electrical equipment and
medical electrical systems used in the home healthcare environment and complies with the
requirements of EN 60601-1-2(EMC), IEC/EN60601-1(Safety) standards. And the manufacturer
is ISO 13485 certified.
PLEASE READ CAREFULLY BEFORE USING
Battery Cap
On/Off
Button
LCD
Probe
PRODUCT ILLUSTRATION
CONTENTS
Figure 1
OWNER S M
ANUAL
’
1 Thermometer, 1 Owner s Manual, 1 Storage Case
’
SPECIFICATIONS
SYMBOL EXPLANATION
Warning :
Read instructions thoroughly before using digital thermometer.
Choking Hazard: Thermometer cap and battery may be fatal if swallowed. Do not allow children
to use this device without parental supervision.
Do not use thermometer in ear. Designed use is for oral, rectal, and armpit (axilla) readings only.
Do not place thermometer battery near extreme heat as it may explode.
Remove battery from the device when not in operation for a long time.
Note: Use of the probe cover may result in a 0.1
℃
(0.2
℉
) discrepancy from actual temperature.
The use of temperature readings for self-diagnosis is dangerous. Consult your doctor for the
interpretation of results. Self-diagnosis may lead to the worsening of existing disease conditions.
Do not attempt measurements when the thermometer is wet as inaccurate readings may result.
Do not bite the thermometer. Doing so may lead to breakage and/or injury.
Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.
After each use, disinfect the thermometer especially in case the device is used by more than one person.
Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is
present. Failure to do so may lead to injury.
Do not use thermometer orally after being used rectally.
For children who are two years old or younger, please do not use the devices orally.
If the unit has been stored at temperatures over 5
℃~
40
℃
(41
℉~
104
℉)
, leave it in 5
℃~
40
℃
(41
℉~
104
℉)
ambient temperature for about 15 minutes before using it.
Direct Current
Type BF Applied Part
Batch Code
Manufacturer
Consult Accompanying Documents
Storage and Transportation
Temperature Limit: -20
℃
~55
℃
(-4
℉ ~
131
℉)
-20
℃
55
℃
EC
REP
European Authorized Representative
Measure Range:
Ambient operating range:
Storage and transportation
condition:
32.0
℃-
42.9
℃
(90.0
℉
-109.9
℉
)(
℃
/
℉
chosen by manufacturer)
±
0.1
℃
(
±
0.2
℉
) during 35.5
℃
~42.0
℃
(95.9
℉
~107.6
℉
) at
18
℃
~28
℃
(64.4
℉
~82.4
℉
) ambient operating range
±
0.2
℃
(
±
0.4
℉
) for other measuring and ambient operating range
Liquid crystal display, 3 1/2 digits
For storing the last measured value
One 1.5 V DC. button battery (size LR41or SR41, UCC 392)
Approx. 200hours of continuous operation or 1 year with 3
measurements per day
12.3cm x 1.8cm x 0.9cm (L x W x H)
Approx. 10 grams including battery
Temperature:
(
)
5
℃~
40
℃
41
℉~
104
℉
Relative humidity: 15%~95%RH
Atmospheric Pressure : 700hPa ~ 1060hPa
Temperature:
(
)
-20
℃
~55
℃
-4
℉~
131
℉
Relative humidity: 15%~95%RH
Atmospheric Pressure : 700hPa ~ 1060hPa
Classification:
Type:
Digital Thermometer (Not Predictive)
Type BF
Direct Mode
Ingress Protection Rating:
IP 22
Accuracy:
Operating mode:
Display:
Memory:
Battery:
Battery life:
Dimension:
Weight:
Expected service life: Three years
DIRECTIONS
2. Position thermometer in desired location (mouth, rectum, or armpit.)
a)
Oral Use:
Place thermometer under tongue as indicated by
position shown in Figure 2. Close your mouth and breathe evenly
through the nose to prevent the measurement from being influenced
by inhaled/exhaled air. Normal temperature between 35.7
and 37.3
(96.3
and 99.1
).
b)
Rectal Use:
Lubricate silver probe tip with petroleum jelly for easy insertion. Gently insert
sensor approximately 1cm (less than 1/2 ) into rectum. Normal temperature between 36.2
and 37.7
(97.2
and 99.9
).
c)
Armpit Use:
Wipe armpit dry. Place probe in armpit and keep arm pressed firmly at side.
From a medical viewpoint, this method will always provide inaccurate readings, and should not
be used if precise measurements are required. Normal temperature between 35.2
and 36.7
(95.4
and 98.1
).
3. The degree sign flashes throughout the testing process. When flashing stops an alarm will beep for
approximately 10 seconds. The measured reading will appear on the LCD simultaneously. The
minimum measurement time until the signaling tone (beep) must be maintained without exception. The
measurement continues even after the buzzer notification.
4. To prolong battery life, press the
On/Off
Button to turn unit off after testing is complete. If no action
is taken, the unit will automatically shut off after around10 minutes.
“√”
℃
℃
℉
℉
"
℃
℃
℉
℉
℃
℃
℉
℉
So that in order to achieve better body
temperature measurement result, recommend to keep the probe in mouth and rectum about 2 minutes,
or in armpit about 5 minutes regardless of the beep sound and at least 30 seconds measurement interval
should be maintained.
*Note: Normally
Alarm b eeps m ore ra pidly w hen te mperature
reaches 37.8
(100
) or higher ,and t
the buzzes are
“
Bi
-
Bi
-
Bi
-
B
i
-
”
;
℃
℉
he buzzes are
“
Bi-Bi-Bi----- Bi-Bi-Bi------- Bi-Bi-Bi
”
followed by last recorded temperature. After showing the self-test temperature, the thermometer is
now in the testing mode.
1. Press the
On/Off
Button next to LCD display. A tone will sound as the screen shows ,
Figure 2
TROUBLESHOOTING
Problem
Solution
Error message
The system is not
functioning properly.
Unload the battery, wait for 1 minute and repower
it. If the message reappears, contact the retailer
for service.
Temperature taken is
lower than 32.0°C(90.0°F)
Turn off, wait one minute and take a new temperature
via close contact and sufficient rest.
Temperature taken is
higher than 42.9°C(109.9°F)
Dead battery: Battery icon is
flashing, can’t be measurable.
Replace the battery.
Turn off, wait one minute and take a new temperature
via close contact and sufficient rest.
CALIBRATION
The thermometer is initially calibrated at the time of manufacture. If the thermometer is used according to
the use instruction, periodic readjustment is not required. However, we recommend checking calibration
every two years or whenever clinical accuracy of the thermometer is in question. Turn on the thermometer
and insert into the water bath and then check the laboratory accuracy of thermometer. Please send the
complete device to the dealers or manufacturer.
The above recommendations do not supersede the legal requirements. The user must always comply with
legal requirements for the control of the measurement, functionality, and accuracy of the device which
are required by the scope of relevant laws, directives or ordinances where the device is used.
M
JOYTECH HEALTHCARE CO.LTD.
No.365, Wuzhou Road, Yuhang Economic Development Zone, Hangzhou city, 311100 Zhejiang,China
A
kçeşme Mah. 2019 Sk. No:5 Merkezefendi DENİZLİ / TÜRKİYE
T
el: +90 258 371 46 56
ww.hunkarmedikal.com
Hünkar Ecza ve Medikal San. Ve Tic. Ltd. Şti
Importer
M
odel:
HNK-ECT-1
The thermometer is guaranteed for
two
year from the date of purchase. If the thermometer does not
function properly due to defective components or poor workmanship, we will repair or replace it free of
charge. All components are covered by this warranty excluding the battery. The warranty does not cover
damages to your thermometer due to improper handling.