JOYTECH DET-3011b Owner'S Manual Download Page 1

Owner's Manual

Infrared Forehead Thermometer

Model

   DET-3011b

Contents

Introduction

1

2

Please read all instructions carefully and thoroughly 
before using this product.

The DET-3011b infrared forehead thermometer is specifically designed 
for safe use on the forehead. The Infrared Forehead Thermometer is 
a device capable of measuring people's body temperature by 
detecting the intensity of infrared light emitted from the forehead.
It converts the measured heat into a temperature reading displayed 
on the LCD. The infrared forehead thermometer is intended for the 
intermittent measurement of human body temperature from the skin
surface of forehead by people of all ages. When properly used, it will
quickly assess your temperature in an accurate manner.

    forehead thermometer. 
2. Do not touch the temperature probe with hands .
3. Use of this Forehead thermometer is not intended as a 
    substitute for consultation with your physician.
4

     some parts are small enough to be swallowed.
5. Never

 

immerse

 

this

 

device

 

in

 

water

 

or

 

other

 

liquids

(

not

    waterproof

).

6. Do not modify this equipment without authorization of 
    manufacturer.
7. Do not expose the thermometer to temperature extremes 
    (below -25

/-13

 or over 55

/131

) nor excessive 

    humidity (>95%RH).
8. Keep the battery away from children

.

 

1. There is no gender or age limitation for using infrared 

Do not allow children to take their temperatures unsupervised,

 

 

 

     

9.Remove battery from the device when not in operation for 
    a long time.      

Warning:

Document No.: JDET-1204-005
Article No.: 005
Version: Z
Date of Issue: 2020.09

Introduction 

......................................................02

Product  Description

LCD Display Introduction    

Basic  Functions

Forehead Thermometer Advantages 

Real  Time  Clock  Setting   

.................................  .  07

Temperature  Taking  Hints

Memory  Mode

Care  And  Cleaning

Battery  Replacement

Specifications

Troubleshooting

Calibration

Service

Warranty

FCC  Information

Electromagnetic Compatibility Information

..

  ...............................................  03

....................................... 04

  ...................................................  05 

  ......................... 06

..

  ...................................09

Illustration  For  Use  ..............................................11

  ........................................................16

  ...............................................17

  ............................................18

  .....................................................19

  ...................................................20

      .............................................................22

  ...............................................................23

  ...............................................................24

    .....................................................25

  ...............27

1.  Probe

2.  START Button

3.  Set  Button

4.  Battery Cover 

Summary of Contents for DET-3011b

Page 1: ...ended as a substitute for consultation with your physician 4 some parts are small enough to be swallowed 5 Never immerse this device in water or other liquids not waterproof 6 Do not modify this equip...

Page 2: ...d with the memory function andhelp you to recognize each measurement result Please see the tinghe first use The thermometer has been designed for practical use It s not meant to replace a visit to the...

Page 3: ...wait 10 minutes before taking a reading 4 Remove dirt from the forehead before taking a measurement Wait at least 10 minutes after washing the forehead area before taking a reading Temperature Taking...

Page 4: ...iting period of 1 seconds between testing is recommended to ensure complete accuracy Note2 If the object to be tested is too far from the probe a prompt will appear See figure 5 To measure forehead te...

Page 5: ...your thermometer will automatically be updated when it s connected with your phone 2 Confirm that your thermometer is connected successfully When your thermometer is connected successfully to your sma...

Page 6: ...heric Pressure Clinical accuracy Dimension Weight Battery Battery life Approx 1 year 6000 readings Measuring site Forehead Forehead Mode Oral This thermometer converts the forehead temperature to disp...

Page 7: ...mometer or to report unexpected operation or events The product is in compliance with the requirements of MDD 93 42 EEC 0197 is the identification number of notify body 0197 European Authorized Repres...

Page 8: ...de 2 kV common mode N A Voltage dips short interrupti ons and voltage variations on p ower supply in put lines IEC 61000 4 11 5 UT 95 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycle 70 UT 30 di...

Page 9: ...ent Rated maximum output power of transmitter W Separation distance according to frequency of transmitter m 80 MHz to 800 MHz 800 MHz to 2 7 GHz 0 01 0 1 1 10 100 0 12 0 38 1 2 3 8 12 0 23 0 73 For tr...