When some problems occur requiring users' attention, the alarming information will be
displayed on the control panel. If several problems occur at the same time, the
alarming information will be displayed in turn. Below is an example:
Below is the detailed description of the control system alarming information:
Alarming information
display position
Temperature sensor disconnected
Control system detects the temperature
sensor is disconnected. Please check the
connection of temperature sensor to the
system. And replace it with a new one if
necessary. ower the system. If the problem
remains, please contact technical support.
Temperature sensor short circuit display
Control system detects the temperature
sensor is short circuited. Please check the
temperature sensor and its connection.
Replace it with a new one if necessary.
F1
:
TEMPERATURE SENSOR
DISCONNECTED
F2
:
TEMPERATURE
SENSOR
SHORTCIRCUIT
Temperature is too high
Reason: the system detects the temperature
sensor's temperature being too high. This can
happen when the heater is on, and there is no
water in the heating pipe or the water flow is too
slim. Action: please ensure there is water in the
SPA tub. If the problems occur frequently, please
contact technical support.
F3
:
TEMPERATURE IS
TOO HIGH
5