background image

When some problems occur requiring users' attention, the alarming information will be 
displayed  on  the  control  panel.  If  several  problems  occur  at  the  same  time,  the 
alarming information will be displayed in turn. Below is an example:

Below is the detailed description of the control system alarming information:

Alarming information 
display position

Temperature sensor disconnected

Control  system  detects  the  temperature 
sensor  is  disconnected.  Please  check  the 
connection  of  temperature  sensor  to  the 
system.  And  replace  it  with  a  new  one  if 
necessary.  ower  the  system.  If  the  problem 
remains, please contact technical support. 

Temperature sensor short circuit display

Control  system  detects  the  temperature 
sensor  is  short  circuited.  Please  check  the 
temperature  sensor  and  its  connection. 
Replace it with a new one if necessary. 

F1

:

TEMPERATURE SENSOR

DISCONNECTED

F2

:

TEMPERATURE

 

SENSOR

SHORTCIRCUIT

Temperature is too high

Reason:  the  system  detects  the  temperature 
sensor's  temperature  being  too  high.  This  can 
happen  when  the  heater  is  on,  and  there  is  no 
water in the heating pipe or the water flow is too 
slim. Action:  please  ensure  there  is  water  in  the 
SPA tub. If the problems occur frequently, please 
contact technical support. 

F3

:

TEMPERATURE IS

TOO HIGH

5

Summary of Contents for PB554

Page 1: ...Simplified operation instruction PB554 V1 0 ...

Page 2: ...yellow blue purple cyan white and off User can switch among these statues by pressing the key Shortcut key light Press this key to turn the main interface upside down And the direction of navigation key will be changed accordingly Short cut key ofScreen Invert WARNING 1 Please connect power strictly accoding to the SPA power data plate 2 Please do not turn the SPA power on until the water reaches ...

Page 3: ... interface In the set interface the character will be highlighted if the cursor is on it Press or to move the cursor location Press to enter into the second level interface of the chosen function or change its status When the manual heating function is started there will be a heating icon added in the function operation interface User can start heating function in the function operation interface ...

Page 4: ...PB554 control panel can store four different modes Mode can store the states of pump blower ozone heater and backlight brightness How to store the setting In move the cursor to the items need to be saved and press If the square on the right side of the item is solid then it indicates the current mode is stored How to select the mode stored In press in turn to select the stored the modes Mode Temp ...

Page 5: ...the control system is off power the correct time setting can be kept for a few days Date Time Ozone OZone has two modes auto and manual Ozone can be set as auto start or manual start In manual start mode there will be an icon added User can start the ozone generator manually in the function operation interface Temprature setting The temperature setting range is 50 to 104 10 to 40 In Set Temperatur...

Page 6: ... a new one if necessary ower the system If the problem remains please contact technical support Temperature sensor short circuit display Control system detects the temperature sensor is short circuited Please check the temperature sensor and its connection Replace it with a new one if necessary F1 TEMPERATURE SENSOR DISCONNECTED F2 TEMPERATURE SENSOR SHORTCIRCUIT Temperature is too high Reason the...

Page 7: ...rom main Board Memory Error Please disconnect the power and wait for 10 seconds to repower the system If the problem remains please contact technical support F8 EEPROM MEMORY ERROR F5 AUTO RESET THERMOSWITCH OPEN Temperature is too low Control system detects temperature sensor s temperature being too low Please pay attention to freezing problem F4 TEMPERATURE IS TOO LOW F9 SYSTEM SETTINGS ERROR Sy...

Page 8: ... Guangming New District Shenzhen China TEL 86 755 26010705 26010708 Sale Tel 26554068 26010859 86 755 Oversea sales 86 13925211653 China sales 86 13602626203 FAX 26010704 86 755 P C 518106 WEB www com joyonway E mail sale1 com joyonway Oversea TEL 86 13510031501 E mail service1 joyonway com China TEL 86 13510031581 AFTER SALES SERVICE ...