CAN Module
For best operation between CAN High and CAN Low, a terminal resistor is required.
A 120
Ω
resistor at each bus end is optimal for a maximum range over longer distances. This is already
integrated in our module and can be activated or deactivated at connection P1.
Connection
Description
NT
Interrupt
SCK
Serial Clock
SI
MOSI
S0
MISO
CS
Chip Select
GND
Ground
VCC1
5V
VCC
3.3V
P2
Additional connection of CANH and CANL signals
P1
Activation / deactivation of the
terminal resistor
CANH
CAN High
CANL
CAN Low