background image

35

This  guarantee  is  offered  as  an  extra  benefit  and  does  not affect your legal rights.
 All electrical appliances produced by Joule are guaranteed by the Company for

2  years

against  faulty material  or  workmanship. 

If  any  part  is found to be defective in this way within the first twentyfour months from the 

date of purchase or hire purchase agreement, we, or our authorised  service  agents,

  will  replace  or  at  our  option  repair  that part  without  any  charge  for  materials  or  labour  or

  transportation, provided that the appliance has been used only in accordance with

the  instructions  provided  with  each  appliance  and  has  been  not connected  to  an  unsuitable 
electricity  supply,  or  subjected  to misuse, neglect or damage or modified or repaired by any person

not authorised by us.

 The correct electricity supply voltage is shown on  the  rating  plate  attached  to  the  appliance.

  This  guarantee  is normally available only to the original purchaser of theappliance, but

the Company will consider written applications for transfer. Should any defect arise

 in any 

 product and a claim under guarantee become  necessary,  the  appliance 

should  be  carefully  packed  and returned  to  your  approved 

 stockist.  

This  portion  of  the guarantee should be attached to the appliance.

UK-IRELAND

Send the guarantee
in sealed envelope to:

     Joule 
     Kylemore Park West,
     Ballyfermot,
     Dublin 10

OTHER COUNTRIES

Please  send  the  guarantee  to
the  retailer’s  address  in  the
country  where  the  appliance
has been purchased.

I authorize 

to include my personal
details within their
database, which they use,
via a third party for the
despatch of advertising
material, at any time, in
accordance with the
regulations in force within
my country. I can have
access to my details and
can request changes, or
prohibit the usage of my
details.This will be done
by addressing my request
directly to:

I authorize 

and its local distributors to include
my personal details within their
database and they can use it
through a third party for the
despatch of advertising material. At
any time, in accordance with the
regulations in force within my
country. I can have access to
details and can ask to make
changes, or prohibit the usage of
my details.This will be done by
addressing my request directly to
the headquarters of the local
distributor where the appliance has
been bought.

I do not authorize
(please tick if required)

I do not authorize
(please tick if required)

 

Joule

Joule

Joule

     Joule 
     Kylemore Park West,
     Ballyfermot,
     Dublin 10

Joule

UK AND IRELAND
CONDITION OF WARRANTY

Summary of Contents for InvaVent 350

Page 1: ...350 Instructions Booklet COD 5 471 084 937 30 02 2018...

Page 2: ...the instructions given in this booklet Following these instructions will ensure a long service life and overall electrical and mechanical reliability Keep this instruction booklet in a safe place Inde...

Page 3: ...pply and no longer used store it out of reach of children and individuals with disabilities Take precautions to avoid any backdraught of gases into the room from the flue or from other open flame appl...

Page 4: ...side through a single dedicated duct The flow of extracted air must be clean i e free of grease soot chemical and corrosive agents and explosive or flammable mixtures Keep the air intake and outlet po...

Page 5: ...Fig 6 Positioning the wall bracket on the wall and marking on wall holes positions using pencil Important respecting the hole wheelbase as shown Fig 7 Verify vertical and horizontal alignment between...

Page 6: ...torque 1 0 N m IMPORTANT Don t use drill but apply screws only manually Connecting air ducts Ducts used for conveying air must be of the correct size Ducts to the outdoors and from the outdoors must...

Page 7: ...ontrol Fig 30 Pre heater Fig 31 Environmental sensors C HCS Cod 12 994 Humidity sensor Fig 32 C TEMP Cod 12 992 Temperature sensor Fig 33 C SMOKE Cod 12 993 Smoke sensor Fig 33 C PIR Cod 12 998 Passiv...

Page 8: ...and the appliance goes into protected mode for one hour with the motors off following which it will restart automatically NOTE Restarting is automatic and don t need User presence By Pass Function Fi...

Page 9: ...the display For more details on setting the time slots and dates see PRG Crono in the Operation and Use section For details on how to activate deactivate the function see Activating deactivating Progr...

Page 10: ...tter A 5 Int Value of the indoor air temperature Example Ext 22 C after pushing the button II See Fig 3 letter B Progr if weekly programming has been activated after pushing the button I NOT UK Market...

Page 11: ...us a different air flow rate To decrease the speed from the HOME page press the key until is displayed 1 Main menu page Press the button from the HOME page to go to a new page entitled Main Menu From...

Page 12: ...SWORD 023 TECHNIC SETP BYP LIFE TIME RESET FIL MBUS ID SPEED LANGUAGE NO FROST Installer Operations menu page Enter the password as shown in the figure to access the installer Operations menu Activati...

Page 13: ...ent address than the default one which is 1 Speed See Fig 3 From Installer menu page selecting Speed you can join to Setting speed Here you can set motorfan speeds C Clean air outlet inside the room D...

Page 14: ...alled on the Fresh air duct See Fig 3 Letter A ATTENTION The appliance is default setted with Heater NOT Enabled factory production So in case of Installing Pre Heater the Installer have to manually a...

Page 15: ...arms page Access the Alarms page only if the machine detects one of the problems detailed below Pre alarm Filters checking without blocking the machine Alarm Filters replacing without blocking the mac...

Page 16: ...e instructions in Maintenance and Cleaning Pressing the key will display NOTE Resetting filters timer See Operation and Use Installer operation menu Reset fil is resetted also the counter Alarm No Fro...

Page 17: ...the note Int probe Call Service Pressing the key will display For technical personnel you must call the Service Alarm Exh Probe damaged The equipment is equipped with an Exhaust temperature probe tha...

Page 18: ...tion page ENGLISH SETUP DATE HOUR PROGRAM PROGRAM Monday Tuesday Wednesday Thursday Sunday Mon Fri Sat Sun Friday Saturday Press the key to confirm Sat Sun Time slot 1 Time slot 2 Time slot 3 Time slo...

Page 19: ...cified intervals however the speeds can be changed manually and in this case the word Man appears in the HOME page NOT UK Markets Speed Airflow Off 1 161 m3 h 2 255 m3 h 3 340 m3 h Boost 360 m3 h Info...

Page 20: ...ed to remove filters closing caps before To remove filters closing caps you have to swipe caps with your hand following the direction shown on closing caps Now filters are available to be removed extr...

Page 21: ...of a replacement It is the user s responsibility to dispose of this appliance through the appropriate channels at the end of its useful life Failure to do so may incur the penalties established by law...

Page 22: ...22 1 1 A 7 7 2 3 5 1 4 6 8 9 2 2 A B...

Page 23: ...23 3 3 A D B C 4 4 a b h 50 mm 60 mm 5 5 6 6 400 mm 110 mm 7 7 8 8 8...

Page 24: ...24 9 9 0 2 0 2 10 10 11 11 To unscrew Torx T25 12 12...

Page 25: ...25 13 13 14 14...

Page 26: ...26 15 15 16 16 To screw Torx T25 Torque 1 0 N m 17 17 18 18 5 19 19 20 20 To unscrew Torx T25 21 21 22 22...

Page 27: ...27 25 25 23 23 24 24 5 26 26 27 27 To screw Torx T25 Torque 1 0 N m...

Page 28: ...emote switch relay 2 OPTIONAL Preheater remote 230Vac relay coil 4 Remote HMI 1 2 3 4 N L 230V 50Hz 1 PE GNYE BU BN PREH PREH BN BU N N L MAINS MAINS 29 29 Mains 2 poles switch 1 POWER SUPPLY VCC A B...

Page 29: ...1 2 POWER SUPPLY PRE HEATER 3 GND BOOST BOOST N L 3 2 1 TM L N 3 Dry contact remote switch relay 32 32 C HCS cod 12 994 3 GND BOOST BOOST 3 Dry contact remote switch relay 33 33 C TEMP cod 12 992 C S...

Page 30: ...30 35 35 36 36...

Page 31: ...31...

Page 32: ...web www joule ie JOULE UK mail Unit 17C D Power Road Plantation Bus Pk Bromborought Wirral CH62 3RN tel 44 0 1513 551 094 fax 44 0 1513 568 336 eml info jouleuk co uk web www jouleuk co uk JOULE PL m...

Page 33: ...33...

Page 34: ...TRE CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE DATE OF WORK STAMP OF TECHNICAL ASSISTANCE CENTRE CERTIFICATE OF WORK PERFORMED UNDER GUARANTEE DATE OF WORK STAMP OF TECHNICAL ASSISTANCE CENTRE CERT...

Page 35: ...ed to your approved stockist This portion of the guarantee should be attached to the appliance UK IRELAND Send the guarantee in sealed envelope to Joule Kylemore Park West Ballyfermot Dublin 10 OTHER...

Page 36: ...arantee is only valid if all details are completed correctly Mailing date Stamp of supplier TO SEND within 8 days from the date of purchese Stamp of supplier Purchase date CUSTOMER DATA name surname s...

Reviews: