66
1.0 Relationship to the
authorities
The installation of a
fi
replace must be in accordance with
the laws and regualtions of each country.
All local regulations, including those referring to national and
European standards, must be observed when installing the
product.
Both an installation manual with technical data and a general
use and maintenance manual are attached to the
product. The installation can only be used after it has been
inspected by a quali
fi
ed inspector.
An approval plate made of heat-resistant material is
placed on the screen plate on the back of the product. It
contains information about identi
fi
cation and
documentation of the product.
2.0 Technical data
Material: Cast
iron
Over-treatment: Black
paint
Type of fuel:
Wood
Max. length of wood:
55 cm
Somke outlet:
Top
Smoke outlet dimension:
Ø200 mm
Weight ca:
220 kg
Additional equipment:
Decor frame, interior ash
solution
Product dimensions, distances:
See
fi
g. 1
Technical data in acc. with EN 13229
Nominal heat output:
14 kW
Flue gas volume:
12,5 g/s
Chimney draught, EN 13229:
12 Pa
Recommended negative pressure
in smoke outlet:
18-20 Pa
E
ffi
ciency:
77 %
CO emission (13% O2):
0,085
%
CO emission (13% O2):
1067 mg / Nm3
NOx (13% O2):
62 mg / Nm3
OGC (13 % O2):
60 mg C /Nm3
Dust (13% O2):
19
mg/Nm3
Air consumption at nominal
performance:
35-40 m3 / h
Chimney temperature EN 13229: 296
0
C
Temperature in
fl
ue:
355
0
C
Recommended wood length:
30-50 cm
Max.
fi
rewood length:
55 cm
Fuel consumption:
4,38 kg/h
Max. intake quantity:
5-6 kg
Nominal inlet quantity:
3 pcs at 33cm, 4,38 kg
Operation:
Intermittent
On all our products there is
a label indicating the serial
number and year. Write this
number in the place indicated
in the installation instructions.
Always quote this serial number
when contacting your retailer
or Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Lot no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR
Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Lot no. Pin.
ENGLISH
Register your
fi
replace on jotul.com
and get a 25 year guarantee.
Contents
1.0 Relationship to the authorities ...........66
2.0 Technical data.......................................66
3.0 Safety ...................................................69
4.0 Mounting ...............................................70
5.0 Daily use ...............................................73
6.0 Maintenance .........................................75
7.0 Service ..................................................75
8.0 Malfunctions-troubleshooting ............76
9.0 Additional equipment ..........................76
10.0 Recycling ..............................................76
11.0 Warranty terms
.....................................77