Jøtul FS 166 -I 570 Installation And Operating Instructions Manual Download Page 8

44

Fig. 9

Bracket 3

Bracket 6

Bracket 1

Bracket 5

Bracket 4

Bracket 2

Bracket 2

Fig. 10

A

B

3mm

NB!: Do not use corner stones marked «223628» before the 
fourth layer.

1. 

Fit the first layer of soap stone on the bottom plate. Use 

bracket 4

 and 

bracket 6

 under to hold them in place.

2. 

Make sure the layer is level and placed correct on the bottom 
plate 

(Fig. 10 A)

. Use a rubber mallet to adjust the stones.

3. 

Place the front stone and corner stones of the second layer 
using 

bracket 1

 

(Fig. 10 B)

.

Fig. 11

A

B

1. 

Position the burn chamber on the stand. Make sure that the 
burn chamber is positioned stably.

2. 

Refit all the parts that were removed for easier handling 
of the insert.

3. 

Mount the first rear plate to 

bracket 6

 that is placed under 

the first layer of soap stone.

4. Mount 

bracket 3

 from the inside through the back plate 

(Fig. 

11 A)

. Use a hammer and knock it gently into the soap stone.

5. 

Place the side stones of the second layer between the corner 
stones and the rear plate. Use 

bracket 3

 to hold it in place

 

(Fig. 11 B)

6. 

Make sure everything is level.

Fig. 12

A

C

D

B

1. 

Remove the lower cover 

(Fig.12 A)

.

2. 

Fit the decorative frame over the door and hook it over the 
front 

(Fig. 12 B)

.

3. 

Attach the trim panel with the same screws as those used 
for the lower cover 

(Fig. 12 C)

.

4. 

Remove the M8 screw provided 

(Fig. 12 D)

.

ENGLISH

Summary of Contents for FS 166 -I 570

Page 1: ...tere Zwecke sorgf ltig aufzubewahren J tul FS 166 I 570 Manual Version P02 J tul FS 166 I 570 NO Monterings og bruksanvisning 2 DK Monterings og brugsanvisning 11 SE Monterings och bruksanvisning 20 F...

Page 2: ...outlet 1587 mm Technical data for burn chamber see installation manual for J tul I 570 Optional equipment Ash solution cat no 50012921 Table of contents 1 0 Relationship with the authorities 38 2 0 T...

Page 3: ...urements floor plate X Y Acc to national regulatives and regulations Combustible wall 900079 P01 J tul FS 166 I 570 R a d i a t i o n z o n e y Fig 1 X 512 1025 536 1587 243 2 1 0 Min 2300 50 294 1835...

Page 4: ...40 3 0 Parts of the surround Fig 2 ENGLISH...

Page 5: ...echnical data for specified weight Remember If a steel chimney resting on the burn chamber is being used the weight of the steel chimney should be taken into account NB It is extremely important that...

Page 6: ...too hard Installation should be carried out by a qualified person Fig 4 Necessary tool during mounting 4mm 10mm 13mm 17mm Spirit level allen key folding ruler wrench rubber mallet and hammer Fig 5 1 D...

Page 7: ...s it was fastened with before 2 If top smoke outlet Mount the heat shield for flue pipe Fig 7 B Fig 8 A NB Hole in floor for external air Fig 8 B 1 D A E B C 50 mm Assemble the stand The stand consist...

Page 8: ...e burn chamber is positioned stably 2 Refit all the parts that were removed for easier handling of the insert 3 Mount the first rear plate to bracket 6 that is placed under the first layer of soap sto...

Page 9: ...shall rest on the attachment bracket Fig 16 A B C 1 Install the flue pipe Top smoke outlet Fig 16 A or rear smoke outlet Fig 16 B If a rear smoke outlet Remove the knockout in the rear plate Fig 16 C...

Page 10: ...intenance If you have the misfortune to find scratches in the surface these may be polished out using a fine sandpaper If deeper scratches are present a paste made of powdered soap stone and water gla...

Page 11: ...83...

Page 12: ...n bedriftens historie startet i 1853 Qualit t J tul AS hat ein Qualit tssicherungssystem das sich bei Entwicklung Produktion undVerkauf von fen und Kaminen nach NS EN ISO 9001 richtet Diese Qualit tsp...