background image

62

4-4424-P02

Pr

oduc

t

Pr

odukt

Distance 

to c

ombustible w

all.

A

vstand 

til br

ennbar v

e

gg

.

Jøtul  MF 

/ F 

TD

212

484

707

367

184

577

Fig 1

522

522

R

adia

tion sone

Str

ålesone

600

707

212

484

TD

MF

 3

Non c

ombustible w

all

C

ombustible w

all

X / 

Y= Acc

. to na

tional r

egula

tiv

es and r

egula

tions.

Min.

 mål gulvpla

te / measur

e floorpla

te

A

vstand 

til ikk

e br

ennbar v

e

gg

.

Distance 

to non c

ombustible w

all.

522

522

x

290

100

600

Y

* 400

* Med skjermpla

te mon

ter

t.

W

ith hea

t shield moun

ted.

Målene g

jelder ubehandlede pr

odukter

. E

tter lakk

ering eller emaljering k

an målene v

arier

e noe.

Dimensions r

e

fer 

to un

tr

ea

ted pr

oduc

ts.

 A

fter pain

ting or enamelling dimensions ma

y ha

ve

 small div

er

gences.

1260

1050

390

600

600

915

* 715

915

* 715

* 400

800

990

* 590

890

600

Summary of Contents for F 3 TD

Page 1: ...L Installatie en montagehandleiding 44 RU 50 CZ N vod k mont i a obsluze 56 Figures Drawings 62 J tul F 3 TD Manual Version P06 Monterings og bruksanvisningen m oppbevares under hele produktets leveti...

Page 2: ...th the product Prior to using the product the installation must be inspected by a qualified person Aproductdatalabelinheatresistantmaterialcanbefoundonthe heat shield underneath the product This conta...

Page 3: ...om within with three screws fig 4A When installing a top flue outlet loosen the traverse fig 5A and remove the top cover plate Fasten the cover on the back side and position the top plate with the flu...

Page 4: ...l Fig 2A Air vent control Fig 2B 5 0 Use 5 1 Choice of fuel Always use quality firewood This will give you optimal results any other fuel may damage the fireplace 5 2 J tul s definition of quality fir...

Page 5: ...oss pattern on top and light the newspaper Gradually increase the size of the wood Leave the door slightly open until the logs catch fire Close the door and ignition vent when the firewood has ignited...

Page 6: ...they can be easily removed by using a soot remover In order to prevent a water and tar layer from forming in the fireplace you should regularly allow the fire to burn hot in order to remove the layer...

Page 7: ...ting Poor draught Check the length of the chimney so that it covers the requirements stipulated in national laws and regulations See also 2 0 Technical data and 4 5 Chimney and flue pipe for informati...

Page 8: ...ves and regulations Min m l gulvplate measure floorplate Avstand til ikke brennbar vegg Distance to non combustible wall 522 522 x 290 100 600 Y 400 Med skjermplate montert With heat shield mounted M...

Page 9: ...63 A B Fig 2 C D Fig 3 A Fig 5 A Fig 4 Fig 6 A D C B...

Page 10: ...not contaminated by external stove cement or glue 9 Produktet har ingen sprekker i glass st pejern eller andre deler There are no cracks in glass cast iron or other parts 9 Pakninger er riktig lagt o...

Page 11: ...tt for siden bedriftens historie startet i 1853 Qualit t J tul AS hat ein Qualit tssicherungssystem das sich bei Entwicklung Produktion und Verkauf von fen und Kaminen nach NS EN ISO 9001 richtet Dies...

Reviews: