background image

8

Stove:

Path:

Articlenumber:

Material:

Date:

Constructed/Changed by:

SCAN A/S

DK-5492 Vissenbjerg©

Drawing 

number:

Name:

C:\Working Folder\Designs\Jøtul F230\90230158.idw

 

90230158

Topplade løftet

25-09-2017

jm

Jøtul F 230

Weight:

Area:

N/A

N/A

B ( 1 : 4 )

B

NAVN:

STI:

M3 NR.:

MATERIALE:

DATO:

SIGN:

DK-5492 Vissenbjerg©

TG.NR:

EMNE:

C:\Working Folder\Designs\Jøtul F230\90230128.idw

 

90230128

Fastgørelse til palle

21-09-2017

jm

Jøtul F 230

VÆGT:

AREAL:

N/A

N/A

 

DIM.:

Scan  A/S

A

 

Stove:

Path:

Articlenumber:

Material:

Date:

Constructed/Changed by:

SCAN A/S

DK-5492 Vissenbjerg©

Drawing 

number:

Name:

C:\Working Folder\Designs\Jøtul F230\90230163.idw

90230163

90230163

AEA

31-10-2017

jm

Jøtul F 234 / 235

Weight:

Area:

N/A

N/A

 

Stove:

Path:

Articlenumber:

Material:

Date:

Constructed/Changed by:

SCAN A/S

DK-5492 Vissenbjerg©

Drawing 

number:

Name:

C:\Working Folder\Designs\Jøtul F230\90230163.idw

90230163

90230163

AEA

31-10-2017

jm

Jøtul F 234 / 235

Weight:

Area:

N/A

N/A

D

C

B

E

Requirement for UK

“The Jotul F 230 stoves have been recommended as suitable 

for  use  in  smoke  control  areas  when  burning  wood  logs 

and  when  fitted  with  a  mechanical  stop  to  prevent  that  the 

secondary air valve cannot be closed lower than 798 mm

2

.” 

Note! 

In order to achieve this see the instruction below.

1.  Remove the top plate 

(A)

.

3.  Remove the three transportation safety screws 

(F)

 in the 

sides and at the front in order to free the stove from the pallet. 

 

 

2.  The AEA - blocking 

(B)

 is mounted with the 2 screws 

(C)

 

and the 2 nuts 

(D) 

at the stove’s secondary air valve 

(E) 

4.0 Installation

• 

Before installing the fireplace, check it carefully for any 

signs of damage

• 

The product is heavy! Ask someone to help you when 

positioning and installing it

• 

Make sure that furniture and other household items are 

at a safe distance from the fi replace to protect them from 

drying out

• 

Do not place anything on the top plate of the stove as this 

could cause permanent damage to the paint/enamel

4.1 Prior to installation

The standard product is delivered assembled.

Fresh air supply

The air used for combustion in any well-insulated house needs 

to  be  replaced. This  is  particularly  important  in  houses  with 

mechanical ventilation. This can be done by using a balanced 

flue pipe. 
The most important thing is to supply the air to the room where 

the stove is placed. 

Important! Ensure that air vents in the 

room where the fireplace is located are not blocked.

For  the  fresh  air  supply  connection,  follow  the  national  and 

local building regulations.

F

Summary of Contents for F 232

Page 1: ...tul F 230 UK Installation and Operating Instructions J tul F 230 Manual Version P00 The manuals which are enclosed with the product must be kept throughout the product s entire service life Register y...

Page 2: ...assemblage l installation ou l entretien de l appareil Cualquier precauci n espec fica que deba tenerse en cuenta durante el montaje instalaci n o mantenimiento del equipo de calefacci n Precauzioni...

Page 3: ...3...

Page 4: ...in the place indicated in the installation instructions Always quote this serial number when contacting your retailer or J tul 1 0 Relationship to the authorities Installation of a fireplace must be a...

Page 5: ...se your fireplace The following instructions must therefore be followed The minimum safety distances when installing and using the fireplace are given in fig 1 The specified distance to flammable mate...

Page 6: ...LE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230125 idw 90230125 M lskitse model 235 14 05 2018 jm J tul F 230 V GT AREAL N A N A DIM Scan A S 1012 236 5 399 204 1...

Page 7: ...NR EMNE C Working Folder Designs J tul F230 90230125 idw 90230125 M lskitse model 235 14 05 2018 jm J tul F 230 V GT AREAL N A N A DIM Scan A S 1012 236 5 399 204 195 972 5 831 470 J tul F 235 J tul F...

Page 8: ...ews F in the sidesandatthefrontinordertofreethestovefromthepallet 2 The AEA blocking B is mounted with the 2 screws C and the 2 nuts D at the stove s secondary air valve E 4 0 Installation Before inst...

Page 9: ...til br ndbar v g 21 08 2017 jm J tul F 230 V GT AREAL N A N A DIM Scan A S 50 254 NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230154 idw 90...

Page 10: ...fore a hole is made in the chimney the product should be test mounted in order to correctly mark the position of the fireplace and the hole in the chimney See fig 1 for minimum dimensions The flue pip...

Page 11: ...sts of a double pipe The outer pipe is used by the stove to draw in fresh air for the combustion The inner pipe is used by the stove to exhaust the burnt gases This is called a balanced vent 1 The ada...

Page 12: ...ith top outlet 1 Position the product correctly see fig 1 2 Position the d cor ring accessory C in the top outlet 3 Pass the flue pipe A through the d cor ring C and the top plate and mount it in the...

Page 13: ...older Designs J tul F230 90230120 idw 90230120 Gulvplade DK NO SE 05 07 2017 jm tul F 230 V GT AREAL N A N A DIM Scan A S A DATO SIGN DK 5492 Vissenbjerg TG NR EMNE orking Folder Designs J tul F230 90...

Page 14: ...tion Avoid smouldering fires as this produces the most pollution The fire is best when it is burning well and the smoke from the chimney is almost invisible Wood consumption J tul F230 has a nominal h...

Page 15: ...oduct is equipped with an air wash for the glass Air is sucked in through the air vent on the top of the product and down along the inside of the glass However some soot will always stick to the glass...

Page 16: ...uld be cleaned and brushed free of any loose particles before new paint is applied Important Never place anything on the top plate of the stove This could cause permanent damage to the paint or enamel...

Page 17: ...0 V GT AREAL 19 49 kg 1074904 mm 2 DIM Scan A S C NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230151 idw 90230151 Udskiftning af frontglas 2...

Page 18: ...18 08 2017 jm J tul F 230 V GT AREAL N A N A DIM Scan A S NAVN STI M3 NR MATERIALE DATO SIGN DK 5492 Vissenbjerg TG NR EMNE C Working Folder Designs J tul F230 90230144 idw 902301 Udskiftning sideglas...

Page 19: ...ses from escaping branches trees etc Upon suspicion of excessive poor draught in the chimney seek professional help for measurement and adjustment The fire extinguishes after a while Make sure that th...

Page 20: ...3 mm 4 Allen screws M5x10 1 Allen screw M5x50 FZB art no 51053190 10 0 Recycling 10 1 Recycling packaging Your fireplace is delivered with the following packaging A wooden pallet that can be cut up an...

Page 21: ...nditions air supply or other circumstances beyond J tul s control 2 4 Cases involving alterations modifications to the fireplace without J tul s consent or the use of non original parts 2 5 Damage cau...

Page 22: ...22...

Page 23: ...23...

Page 24: ...J tul AS has a quality system that conforms to NS EN ISO 9001 for product development manufacturing and distribution of stoves and fireplaces This policy gives our customers quality and safety piece...

Reviews: