11
Fig. 4
A
B
For Jøtul F
164
and Jøtul F
165
:
1. Remove the heat shield
(Fig. 4 A)
.
2. Loosen the screw
(Fig. 4 B)
.
3. Adjust the spring by moving the bracket.
4. Tighten the screw.
5. Refit the heat shield.
For Jøtul F
166
and Jøtul F
167
:
1. Loosen the screw
(Fig. 4 B)
.
2. Adjust the spring by moving the bracket.
3. Tighten the screw.
4.6 Leveling the fireplace
Fig. 5
NB! If a glass front plate is used, raise the base 6mm up from
the floor. Then slide the glass front plate underneath the front
of the base.
4.7 Fitting the flue pipe with the rear
outlet
The product is supplied from the factory with the smoke outlet
fitted for the top outlet.
NB! Proceed as follows for installation with a rear outlet:
Fig. 6
1. Lift the baffle
(Fig. 6 A)
up carefully.
2. Remove one of the side burn plates by lifting them up a little
and then out. (Be aware if using tools, that vermiculite plates
may be damaged by rough handling).
3. Remove the baffle.
4. Remove the other side burn plate.
5. Remove the exhaust deflectors
(Fig. 6 B)
.
Fig. 7
6. Unscrew the screws
(Fig. 7 A)
and remove the smoke outlet
(Fig. 7 B)
from the top outlet from the inside of the burn
chamber.
ENGLISH