Jøtul Classic F 500 V3 Installation And Operating Instructions Manual Download Page 29

F 500 V3 Oslo   4 / 20

29

Some states do not allow the exclusion or limitation of 

incidental or consequential damages, or limitations on the 

length of implied warranties.  Therefore, the above exclusions 

or limitations may not apply to you.  This warranty gives you 

specific legal rights, and you may have other rights, which vary 

from state to state. 

JØTUL reserves the right to discontinue, modify or change 

the materials used to produce the Jøtul stove or fireplace.  

JØTUL shall have the right to replace any defective component 

with substitute components determined by JØTUL to be of 

substantially equal quality and price. 

The dollar value of JØTUL’s liability for breach of this warranty 

shall be limited exclusively to the cost of furnishing a 

replacement component.  JØTUL shall not in any event be 

liable for the cost of labor expended by others in connection 

with any defective component.  Any costs or expenses beyond 

those expressly assumed by JØTUL under the terms of this 

warranty shall be the sole responsibility of the owner(s) of the 

Jøtul or stove or fireplace.

No dealer, distributor, or other person is authorized to modify, 

augment, or extend this limited warranty on behalf of JØTUL.  

NO MODIFICATION OR CHANGE TO THIS WARRANTY WILL 

BE EFFECTIVE UNLESS IT IS MADE IN A WRITTEN DOCUMENT 

MANUALLY SIGNED BY AN AUTHORIZED OFFICER OF JØTUL.

An authorized installer may have been provided with certain 

information related particularly to the Jøtul or stove or 

fireplace; however, no authorized installer or other person who 

may service the appliance is an agent of JØTUL.  No inference 

should be made that JØTUL has tested, certified, or otherwise 

pronounced any person as qualified to install or service the 

appliance.  JØTUL shall not be liable or otherwise responsible 

for any error or omission by a person installing or servicing a 

Jøtul or stove or fireplace.

If you believe your Jøtul stove or fireplace is defective, you 

should contact your nearest authorized Jøtul dealer, who 

will process a warranty claim.  IN ORDER TO QUALIFY FOR 

WARRANTY COVERAGE, JØTUL MUST RECEIVE NOTICE OF A 

POSSIBLE DEFECT WITHIN SIXTY (60) DAYS OF THE DATE THE 

DEFECT IS FIRST DISCOVERED, OR REASONABLY COULD HAVE 

BEEN DISCOVERED.

This warranty is given by Jøtul North America, Inc., 

55 Hutcherson Drive, Gorham, Maine 04038 USA 

    

Return to: 

  Applied 

Ceramics 

 

 

Customer Service Department

 

5555 Pleasantdale Road

 

Doraville, GA 30340

 

(770) 448-6888 Main / (678) 735-4937 Direct

CUT

Name:  _________________________________________

Address: _______________________________________

City: ___________________________________________

State:______________________  Zip: _______________

Telephone ______________________________________

Date of Purchase: ________________________________

Place of Purchase:________________________________

APPLIED CERAMICS COMBUSTOR  WARRANTY  

 

 

                         REGISTRATION CARD

Dealer Address: ________________________________

______________________________________________

Stove Manufacturer: ____________________________

Stove Model ___________________________________

Jøtul High Flow™ Catalytic Combustor 158000 

20-Year Limited Warranty

 

 

J

øtul North America, Inc. warrants to the consumer who 

purchases a Jøtul High Flow™ Combustor as a component 

in an EPA-Certified Jøtul solid fuel appliance, 100% against 

defects in materials and workmanship for a period of 20-years 

from the date of purchase.  

 

Conditions and Exclusions:

 

1)    The Jøtul High Flow™ Combustor 20-Year Warranty is to  

 

the original purchaser of the Jøtul wood stove or insert  

 

and is non-transferable.

2)    The Jøtul High Flow™ Combustor 20-Year Warranty does  

 

not apply to any other component of the Jøtul wood stove  

 

or insert.

 

3)    The Jøtul High Flow™ Combustor 20-Year Warranty covers  

 

replacement of the original Jøtul High Flow™ Combustor  

 

due to defects in material and workmanship.

 

4)    Return the defective combustor to your local Jøtul    

 

Authorized Dealer who will submit a warranty claim on  

 

your behalf.  All claims must be accompanied by a proof  

 

of purchase showing the name of the selling dealer, date  

 

of purchase, Jotul stove or insert model and serial number.  

 

Retain your sales receipt for your records.

 

5)    Related cost of replacement such as installation, travel,  

 

and shipping are excluded.

 

6)    Return of the original Jøtul High Flow Combustor™ to Jøtul  

 

North America may be requested.

 

7)    Any subsequent replacement Jotul High Flow™ Combustor  

 

is not covered under this original warranty. Subsequent  

 

claims will be covered by the Applied Ceramics, Inc.    

 

combustor warranty. See contact and claim information  

 

below and on the next page.

  

Summary of Contents for Classic F 500 V3

Page 1: ...make them available to anyone using or servicing this wood heater This wood heater contains a catalytic combustor that requires periodic inspection and repair for proper operation See this manual for...

Page 2: ...tove Inspection 13 6 2 Ash Removal 13 6 3 Chimney System 13 6 4 Enamel Care 13 6 5 Glass Care Glass Replacement 14 6 6 Gaskets 14 7 Accessories 15 8 Illustrations Figures 16 21 Clearance Chart and Dia...

Page 3: ...NDING WHEN ADDING FUEL Avoid creating a low pressure condition in the room where the stove is operating Be aware that operation of an exhaust fan or clothes dryer can create a low pressure area and co...

Page 4: ...ws The maximum horizontal run is 36 915mm and a recommended total length of stove pipe should not exceed 10 feet Horizontal runs must slope upward 1 4 6 35mm per foot toward the chimney Where passage...

Page 5: ...collar Larger chimney flues should be relined with a listed or code approved liner The masonry chimney must have a fireclay liner or equivalent with a minimum thickness of 5 8 16mm and must be instal...

Page 6: ...be installed to resize the flue The fireplace installation must also conform to the tested clearances to surrounding trim and mantels See clearance specifications on pages 22 23 In addition a fireplac...

Page 7: ...50 5 deep 1168mmx1283mm can be used only if the left side door is locked to prevent use Door Lock Kit 155850 is available for this purpose from your dealer 4 2 Clearances to Walls and Ceilings The fo...

Page 8: ...ned 2 All chimney components including chimney sections supports spark arrestor etc shall comply with the Standard for Factory built Chimneys for Residential Type and Building Heating Appliances UL 10...

Page 9: ...as the stove The monitor should be located as far away as possible from the stove to avoid alerts when the doors are opened 5 3 Wood Fuel and Performance Use dry wood The F 500 V3 is designed to burn...

Page 10: ...d into the atomosphere When the combustor is functioning no smoke will be observed exiting the chimney This is evidence that the stove is operating in the so called sweet spot wherein optimum efficien...

Page 11: ...or the most efficient burn is between 400 and 600 204 C 316 C 2 Take the magnet off of thermometer and replace into the correct orientation as shown in fig 13c 13e 3 Place the thermometer fully into h...

Page 12: ...full open position far right To minimize any smoke spillage open the door slightly before opening fully This will allow air flow to stabilize within the firebox and chimney flue Use a stove tool or po...

Page 13: ...h to empty the drawer and then securely closed Inspect the gasket on the ash pan door regularly and replace as necessary 6 Maintenance See Appendix A page 24 for Combustor Maintenance and Replacement...

Page 14: ...pattern as you would tighten the lugs on an automobile wheel 6 6 Gaskets Check door and glass panel gaskets for tightness To check the seal of the front door close and latch the door on a dollar bill...

Page 15: ...ed with Rear Heat Shield 154332 not included Outside Air Kit 154335 Provision for outside air may be required by your local building codes The outside air kit includes a 3 inch adapter used to connect...

Page 16: ...F 500 V3 Oslo 4 20 16 Fig 1a Fig 1b Fig 4 Masonry chimney penetration Fig 3 Chimney height 3 2 10 Rule Fig 2 Chimney connector assembly 8 Illustrations Fig 5 Chimney thimble components 24 3 4 629mm...

Page 17: ...ns 2 50 mm Min width 50 5 1283mm Min width 56 1422 mm 18 460 mm 8 200 mm 8 200 mm 18 460 mm Min depth 50 1 2 1283 mm Min width 54 1 4 1378 mm Fig 6 Fireplace chimney construction Fig 7 Prefabricated c...

Page 18: ...ature Monitor FULLY CLOSED FAR LEFT FULLY OPEN FAR RIGHT Combustion Monito r DO NOT REMOVE THIS SET SCREW Fig 13b Fig 13c Removemagnetfromcurrentorientation Fig 13d Orient magnet Incorrect Orientation...

Page 19: ...e bottom 1 Bend the flattened heat shield on the perforations as shown painted side down 2 Use a 10 mm wrench to remove the two bolts from the bottom of the ash compartment Unpainted Side Up Fig 16 Bo...

Page 20: ...F 500 V3 Oslo 4 20 20 F 500 V3 Illustrated Parts Breakdown Purchase replacement parts only from a J tul Authorized dealer...

Page 21: ...le Cast Straight 10243892 31 Spring Door Handle 126164 32 Coiled Spring Pin 5x24 118070 33 Washer Door Handle 117587 34 Gasket Round LD2 375 Graphite 225695 35 Insulation Blanket Burn Plates 128903 36...

Page 22: ...e Protected surface Single wall pipe 18 460mm 12 300mm Double wall pipe 6 150mm 6 150mm Fireplace Mantle and Trim Clearance no shielding reduction permitted Stove Side to Side Trim 1 thick or less 12...

Page 23: ...ce Parallel to the Wall Unprotected Surface Corner Installation Protected Surface Corner Installation E F A G C F A G F A D F D D D B F F F F D A D F D D D F D D PER NFPA 211 or CAN CSA B365 Important...

Page 24: ...periodically monitor the operation of the catalytic combustor to ensure that it is functioning properly and to determine when it needs to be replaced A non functioning combustor will result a loss of...

Page 25: ...nd the front plate inside the stove as in fig 19 2 Use the 3mm hex key to remove the two M6x40 set screws on the left and right sides See fig 20 2 Wearing gloves grasp each side and lift the front of...

Page 26: ...F 500 V3 Oslo 4 20 26 Fig 24 Left and Right Side insulation panel removal and replacement Fig 23 Lift combustor from the chamber Expansion gasket RRefactory member...

Page 27: ...lue 3 If the overall R value of the system is greater than the R value of the specified floor protector the alternate is acceptable Example The specified floor protector should be 3 4 thick material w...

Page 28: ...sions and Limitations Notice This warranty is void if installation or service is performed by someone other than an authorized installer or service agency or if installation is not in conformance with...

Page 29: ...EASONABLY COULD HAVE BEEN DISCOVERED This warranty is given by J tul North America Inc 55 Hutcherson Drive Gorham Maine 04038 USA Return to Applied Ceramics Customer Service Department 5555 Pleasantda...

Page 30: ...eplacement STEEL COMBUSTOR fails to function the prorated warranty will allow replacement at the following special price schedule Year 3 130 00 Year 4 140 00 Year 5 150 00 Year 6 160 00 Year 7 and aft...

Page 31: ...F 500 V3 Oslo 4 20 31 This page is intentionally left blank...

Page 32: ...box 1411 N 1602 Fredrikstad Norway www jotul us 139946_R10 April 2020 For Your Records Record the following information to help your dealer determine what you will need should your stove ever require...