Setting Up Your Mug Press

 Turning On Your Mug Press

 

Turn the Main Power Switch ON.  The  

 

Main Power Switch is at the right/Left side  

 

of the heat press.  

 

Current temperature will display.  Usually has the value

 

       

“LO”, indicating low temperature.

How to Read The Display

1.) If a number value shows on this display and no lights 

 

     are on in either of the middle three slots, mug press is  

 

displaying the current temperature. 

2.)  If the display has a value of “LO” it means low 

 

      current temperature (under 200˚F (93˚C)).

Setting Press Temperature

 

1.) Press OK to start for 2 seconds. Use the up and down 

 

    arrows to choose to display in °F or °C.   

 

    °F stands for Fahrenheit 

 

    °C stands for Celsius

 

2.) Once you select Fahrenheit or Celsius, press OK to save.

 

3.) Use the arrow to change the value of the set 

 

           temperature.  The left light in the middle is on to 

           indicate you are in the set temperature mode. 

 Setting Press Time

 

Press the OK button to save the set temperature value

 

 

Now change the set time value with the up and down

 

      arrows. Please note, the set time is in seconds.
      The middle light in the middle is lit to indicate you are 

      in the set temperature mode. Now Press OK to save 

 

      the set time value. 

     Wait until the current temperature is the same as the set  

     temperature before using. The press will beep once set temperature is reached.   

     Close and open the press to stop the beeping.

Note: This mug press should not be set to exceed 400˚F (200˚C).  Setting the press temperature 

to above 400˚F (200˚C) will burn out your mug element and may cause a fire hazard.

Summary of Contents for E-HP-JMP-2S5E

Page 1: ...Joto Digital Mug Press Manual Dual Station includes 5 Elements Model No E HP JMP 2S5E OPERATOR S MANUAL Dual Station Includes 5 elements This product is SGS Electrical Safety Certified...

Page 2: ...epair could increase the risk of fire electric shock or injury to persons when the equipment is used If mug press being used by or near children please make sure that it is supervised Do not leave equ...

Page 3: ...requires written consent from Joto Errors and amendments of technical details excepted all rights reserved Joto is not liable for any direct or indirect damages caused by the use of this product Tabl...

Page 4: ...x235mm for 6oz 9oz 10oz etc Mug 130x235mm for 11oz 15oz etc Mug 12oz 17oz Latte Mug Voltage 220V 1Phase 110V 1Phase Power 2x 300W 600W 5 5A Recommended Settings 30 280s 356 400 F or 180 200 C Time Ran...

Page 5: ...5 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Mug Press Overview FRONT VIEW SIDE VIEW TOP VIEW...

Page 6: ...lies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Machine Parts Diagram Mug Heater Limit Switch Digital Controller Handle Bar Grip Pressure Adjustment Knob Power Switc...

Page 7: ...in F or C F stands for Fahrenheit C stands for Celsius 2 Once you select Fahrenheit or Celsius press OK to save 3 Use the arrow to change the value of the set temperature The left light in the middle...

Page 8: ...n Jar 12oz Enamel Cup 14oz 17oz Travel Mug 16oz 20oz Beer Stein Water Bottle Element SKU X HP JMP 02 17oz Coke Shaped Bottle Water Bottle with Bamboo lid 650ml Aluminium Bottle with Straw Stainless St...

Page 9: ...press Close the mug press Note Ensure the timer starts immediately after closing the press If it does not take the bottle out wait for the temperature to go up to the set temp 6 Timer will start coun...

Page 10: ...detailed instructions 4 With the Mug Press open unscrew the four screws that hold the mug element in place 5 Gently slide the mug element out of the mug press Please be careful not to damage the cord...

Page 11: ...ce Mug elements will wear out over time When they wear out you will need to replace them with new ones The rated life expectancy of an mug element is approximately 1000 2000 mugs Elements may wear out...

Page 12: ...agingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Expanded Diagram 18 19 34 21 15 38 1 6 10 7 16 23 13 14 17 22 19 25 28 29 30 31 33 37 2 8 3 4 5 9 12 20 36 2...

Page 13: ...witch 2 16 Mug Press Handle Base 2 17 Guide Post 1 2 18 Mug Press Handle 2 19 Mug Press Handle Connector 4 20 Rivet Head 12 21 Mug Press Handle Plate 2 22 Switch Plate 2 23 Mug Element Top Plate 2 Ser...

Page 14: ...14 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Circuit Diagram...

Page 15: ...d JOTO will ship the replacement or repaired component freight prepaid by JOTO g This warranty is effective only if the product or component is installed in a location and manner prescribed by JOTO in...

Page 16: ...www jotoimagingsupplies com Tel 1 800 565 5686 Fax 1 800 565 5622 Coquitlam BC Brampton ON Blaine WA Las Vegas NV Antioch TN...

Reviews: