 How to adjust pressure 

(figure 1.1)

:

 

1. Connect the heat press with air compressor or air sources.

 

2. Lift up the cap of air valve as the picture four shown

 

3. Revolve the cap anti clockwise, the air pressure goes down; conunter clockwise, the air  

     

    pressure goes up; when you finish the pressure adjustment, push down the cap.

 

4. Suggested air pressure is 0.6~0.8 Mpa. It depends on the transfer materials.

How to Read The Display

1.) Turn on Heat Press, display screen will switch on
2.) Right side PV value = Current Temperature
3.) Left side PV value = Current Time
4.) Right side SV value = Set Press Temperature
5.) Left side SV value = Set Press Time

Setting Press Temperature

 

Press the corresponding number of SV to start.   

 

Touch the °F or °C buttons to choose to display  

 

in °F or °C.   

 

°F stands for Fahrenheit 

 

°C stands for Celsius

 

Press ENT to save and exit,  

 

CLR to clear the settings, ESC to reset.

 

Use keypad to set press temperature value.   

 

Press ENT to save 

 Setting Press Time

 

Press the SV Time Value and a keypad will  

 

show up. 

 

Press the numbers on the keypad change 

 

the value.

 

Press ENT to save the value. 

Wait until the current  

 

temperature is the same as the set temperature  

 

before using.  The press will beep once set temperature  

 

is reached.  Close and open the press to stop the beeping.

Setting Up Your Heat Press

Note:  Setting the press temperature to above 400˚F (200˚C) may cause a fire hazard.

Summary of Contents for E-HP-JLF-XSTM-40

Page 1: ...Joto Pneumatic Large Format Heat Press XSTM 40 XSTM 48 Model No E HP JLF XSTM 40 E HP JLF XSTM 48 OPERATOR S MANUAL...

Page 2: ...f you are not qualify to do so Instead call or take it to a qualified service person for examination and repair Incorrect assembly or repair could increase the risk of fire electric shock or injury to...

Page 3: ...ual carefully Reproduction of this manual requires written consent from Joto Errors and amendments of technical details excepted all rights reserved Joto is not liable for any direct or indirect damag...

Page 4: ...x 100cm Up to 40 x 48 100 x 120cm Controller GY 06 Digital Controller GY 06 Digital Controller Printable Materials Up to 6 96 177mm thickness Up to 6 96 177mm thickness Voltage 380V 3 Phase 380V 3 Ph...

Page 5: ...65 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Machine Parts Diagram PLC Digital Touch Screen Up and bottom tray Air filter Over wire explosion proof box Left and right borders Gre...

Page 6: ...lue Current Time 4 Right side SV value Set Press Temperature 5 Left side SV value Set Press Time Setting Press Temperature Press the corresponding number of SV to start Touch the F or C buttons to cho...

Page 7: ...nsure please refer to the instructions you received with your transfer materials 7 Push the green start up switch The platen will close automatically The current time value will start counting down On...

Page 8: ...onds Peel Hot to Cold MultiCut Style Temperature 310 330 F Time 15 20 seconds Peel Hot to Cold Transfer Vinyls CL TrimFree Dark REQUIRE A WHITE TONER PRINTER Temperature 310 F 1st Press Time 120 secon...

Page 9: ...e 120 seconds Peel Immediate Method Substrate face up Image face down iLumipiX Photo Panels Temperature 400 F Time 65 150 seconds Time may varied based on size Scan the QR code on the left for instruc...

Page 10: ...if heat press is not used for more than 30 minutes The heat releasing fan will automatically starts when the temperature of heat platen reaches 80 degree C 176 degree F It helps to reduce the temperat...

Page 11: ...11 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Schematic Diagram...

Page 12: ...12 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Expanded Diagram...

Page 13: ...electric control box 1 7 Rear rail fixing plate 2 27 Cover plate for heat platen 1 8 Front rail fixing plate 2 28 Fixing bolt 6 9 Solenoid valve 2 29 Upper adapter plate 1 10 Front plate 1 30 Governor...

Page 14: ...14 www jotoimagingsupplies com 1 800 565 5686 Blaine WA Las Vegas NV Antioch TN Coquitlam BC Brampton ON Circuit Diagram...

Page 15: ...purchaser and JOTO will ship the replacement or repaired component freight prepaid by JOTO g This warranty is effective only if the product or component is installed in a location and manner prescribe...

Page 16: ...www jotoimagingsupplies com Tel 1 800 565 5686 Fax 1 800 565 5622 Coquitlam BC Brampton ON Blaine WA Las Vegas NV Antioch TN...

Reviews: