Replacing Platen Element
Replacing your Heat Element
1.) Ensure the power switch is OFF.
2.) Unplug the heat press if it is still plugged in.
3.) Detach the platen element cord from the mug press. Unscrew the ring that holds
the cord in place before detaching. See below diagram for detailed instructions
4.) With the Heat Press open, unscrew the two screws that hold the heat
element in place.
5.) Gently remove the heat element out of the flat and cap heat press. Please be careful not
to damage the cord or the mug press.
6.) Gently install the new heat element into the flat and cap heat press.
7.) Re-screw the two screws to keep the heat element in place.
8.) Connect the new heat element cord to the heat press.
Ensure that the pattern on the cord matches the socket on the heat press.
Heat Element
Cord and Ring
2 Screws that
Hold Element in
Place