background image

User and Service manual JO960 
Ver. 2.0

 

Ver. 1.1

 

6

 

 

Before using JO960 

 

  Heat only naturally magnetic material. 

  Check that all necessary safety precautions have been taken. (see 

Safety instructions on page 3)

  Anyone operating the JO960 should avoid to wear or have metal 

objects such as watches, ring, keys etc. Since these objects could be 
heated unintentionally by the magnetic field from the heating tip. 

  The working area should be cleared from combustible items to 

prevent these items being ignited by the work piece being heated by 
this equipment. 

 

 

 

 

Summary of Contents for JO960 A

Page 1: ...T 65 1 0505 Operator Instruction and Safety regulations Induction Heating system JO960 A ...

Page 2: ...on should be read through by the operator as well as service personnel However only qualified personnel should carry out troubleshooting and maintenance Safety instructions Safety instructions will be found throughout the manual where appropriate All safety instructions will be marked with the following symbol Advice and warnings Important information is marked with the symbol below This informati...

Page 3: ...e JO960 will concentrate a powerful magnetic field at the end of the heating tip This magnetic field creates eddy currents in the material thus creating heat Technical data Size including handles and wheels 1300 x 660 x 900 mm LxWxH Weight full water tank 180 Kg Output power 13 kW Frequency 15 kHz Enclosure IP62 Installation Mains supply Mains supply 3 x 380 400V 3Ph PE Frequency 50 60 Hz Recommen...

Page 4: ...h must be turned off and the plug disconnected from the power line socket prior to any form of maintenance being performed Remark There will be remaining current approx 10 min after disconnecting the heater Do not touch any object that has been near the heating tip without ensuring that it has cooled off Always comply with all safety measures when handling electrical equipment including any nation...

Page 5: ...h is turned on the cooling unit will start functioning All other controls and indicators are mounted on the front panel 2 Controls Start Reset switch Prior to working with JO960 this switch must be activated Operation This indicator will be illuminated when the start switch placed on hand held transformer is activated and the JO960 curcuits function correctly Figur 1 Controls and indicators 0 1 1 ...

Page 6: ...n the main switch to JO960 is switched on but the heater is not started This indicator will not be illuminated after the Reset Start switch has been pressed OVER TEMPERATURE This indicator will be illuminated if the cooling water temperature exceeds 30 C WATER FLOW This indicator will be illuminated if the cooling water is not flowing correctly COOLING UNIT This indicator will be illuminated at an...

Page 7: ... Safety instructions on page 3 Anyone operating the JO960 should avoid to wear or have metal objects such as watches ring keys etc Since these objects could be heated unintentionally by the magnetic field from the heating tip The working area should be cleared from combustible items to prevent these items being ignited by the work piece being heated by this equipment ...

Page 8: ...ily No higher effect will be reached through pressing the heating tip against the work piece It is quite sufficient to put the heating tip against the work piece 6 Release the on off switch when the work piece has reached the correct temperature See e g JOSAM s colour scale T43 1 2 3 9712 and the heating tip stops heating Handling instructions for JO960 JO960 is divided into two main parts The top...

Page 9: ...urn open the knob 6 on figure 2 and carefully lift the electronic part upper painted red lift it to upright position 1 Water tank contains 40 litre cooling media 2 Filling hole 3 Thermostat 4 Condensor 5 High pressure pressostat 6 Opening knob Figure 2 Cooling unit 2 1 3 4 5 6 ...

Page 10: ...s and the freezing point can no longer be controlled If Ethylenglycol is not available the water tank must be emptied completely before it is refilled Setting of the temperature of the cooling water To secure that JO960 works satisfactorily the temperature of the cooling water must be set correctly Factors that will influence this setting is The time and frequency when the machine is used for heat...

Page 11: ...REMARK Never use a high pressure washer it might damage the condensor Electronic part The electronic part does not contain any parts the requires special care At the bottom of this part there are four 4 fuses To access the fuses unit turn the handle and carefully lift the electronic unit top painted red to an upright position F1 32A Main fuse to electronic unit F2 2A Water pump F3 10A Cooling fan ...

Page 12: ...bent or in any other way damaged Remark A damaged heating tip should always be changed Changing of heating tip 1 Switch off the main switch 2 Loosen the hexagon screws 3 Loosen the heating tip 4 Check that all contact surfaces are undamaged and clean Remark Never use any grease or fat on the contact surfaces Figur 4 Changing of heating tip Hand held transformer 4 pcs Hexagon screws Heating tip 2 p...

Page 13: ...12 5 Assemble the new heating tip Check that the O rings are not damaged Remark Never replace the previous screws with screws of magnetic material 6 If necessary alter the position of start stop switch Remark Use only heating tips supplied by JOSAM ...

Page 14: ...r a long time it might be necessary to reset the thermostat to a higher position and lower the temperature Airflow through the machine is obstructed due to the fact that the sides of the machine or the condensor the cooling unit is filled with dirt Cleaning of the condensor is described on page 10 Before using the machine again the high pressure safety pressostat must be reset See 5 on Figure 2 Am...

Page 15: ...has blown The cables hand held transformer or heating tip are malfunctioning Check that they are not damaged in any way Reset indicator is illuminated when the electronic unit of JO960 does not work properly Possibly caused by Shortcircuit of heating tip or hand held transformer If the heating tip is damaged it must be changed see Changing of heating tip on page 11 Inadequate earthing for hand hel...

Reviews: