background image

061920

© 2020 Jomar Valve  •  www.jomarvalve.com  •  P: (586) 268-1220  •  F: (586) 979-8315

Note: Information subject to change without notice.

3

3.4 Assembly 

The assembly process, is opposite to the 

disassembly process.  The ball must be at the 

closed position when assembling the body 

and end cap.  The stop plate must be correctly 

positioned on the stem otherwise, the open 

and close operation will be reversed. 

Final inspection of repaired valve. It is 

necessary to operate the valve open and 

closed to ensure all the parts are assembled 

correctly.  Be sure the torque is the same 

during the open/close operation.  If the 

torque is not the same during operation, it 

may have some parts positioned incorrectly or 

be experiencing interference. If this happens, 

it must be disassembled and re-assembled.  

The valve will be damaged if it is placed back 

in the pipeline while wrongly assembled and 

may be a safety hazard.

3.5 Tightening torque of gland bolts

Gland bolts can loosen after the valve is in 

use over a period of time, and cause leakage. 

It is necessary to check the gland bolts 

periodically.  If the bolts are loose, tighten 

according to torque data given below.

4.  Torque Data

PACKING GLAND

FL-CS-100-150 & FL-SS-100-150 

SIZE

Bolt Size

N-m

(kgf-cm)

Tolerance

1/2”

1/4”-20UNC

2

20

+/- 10%

3/4”

1/4”-20UNC

2

20

1”

5/16”-18UNC

4

40

1-1/4”

5/16”-18UNC

4

40

1-1/2”

3/8”-16UNC

10

100

2”

3/8”-16UNC

10

100

2-1/2”

3/8”-16UNC

10

100

3”

W1/2”-

12UNC

20

200

4”

5/8”-11UNC

30

300

5”

5/8”-11UNC

30

300

6”

5/8”-11UNC

30

300

8”

5/8”-11UNC

30

300

 

FL-CS-100-300 & FL-SS-100-300 

SIZE

Bolt Size

N-m

(kgf-cm)

Tolerance

1/2”

1/4”-20UNC

2

20

+/- 10%

3/4”

1/4”-20UNC

2

20

1”

5/16”-

18UNC

4

40

1-1/2”

3/8”-16UNC

10

100

2”

3/8”-16UNC

10

100

3”

W1/2”-

12UNC

20

200

4”

5/8”-11UNC

30

300

5”

5/8”-11UNC

30

300

6”

5/8”-11UNC

30

300

 

BODY BOLTS

FL-CS-100-150 & FL-SS-100-150 

SIZE

Bolt Size

N-m

(kgf-cm)

Tolerance

1/2”

5/16”-18UNC

25

250

+/- 10%

3/4”

5/16”-18UNC

25

250

1”

3/8”-16UNC

40

400

1-1/4”

3/8”-16UNC

40

400

1-1/2”

7/16”-14UNC

45

450

2”

7/16”-14UNC

45

450

2-1/2”

7/16”-14UNC

45

450

3”

1/2”-13UNC

75

750

4”

1/2”-13UNC

75

750

6”

5/8”-11UNC

182

1850

8”

3/4”-10UNC

350

3500

 FL-CS-100-300 & FL-SS-100-300 

SIZE

Bolt Size

N-m

(kgf-cm)

Tolerance

1/2”

5/16”-

18UNC

25

400

+/- 10%

3/4”

5/16”-

18UNC

25

400

1”

3/8”-16UNC

40

400

1-1/2”

7/16”-

14UNC

45

450

2”

7/16”-

14UNC

45

450

3”

1/2”-13UNC

75

750

4”

5/8”-11UNC

182

1850

5”

3/4”-10UNC

350

3500

6”

1”-8UNC

569

5800

Reviews: