- 10 -
Click on the main interface of the icon, numerical to view view Settings related information of lamps and
lanterns.Symbols such as the main interface appear “ “,the following error message indicates that there
might be a lamps and lanterns,can click to view and control information content to modify the lamps and
lanterns.
This lamp can be set to turn off the automatic flip screen function, touch this " “ icon can be manually
flip screen.
CODE ERRO INFO
CHECK MEASURMENT
NOTE
E02
Program Err 1
Check the welding of Chip
E04
MBDInit Error
Check the communication signal 485& 485 chip &
E05
BD1Init Error
E06
BD2Init Error
E12
Bus1 Error
Check main cable ABAB(485) chip
E16
MFpga Error
E17
BD1 BUS
E18
BD2 BUS
E21
Pan FB. Error
E23
Tilt FB. Error
E22 Pan Zero Error
E24
Tilt Zero Error
E46
H.Fan Error
Check the fan of head
RESET
ERROR
Check main cable ABAB(485) chip
Check the communication signal& welding of
communication chip
Check the light coupling line, optical coupling switch and
a plate of the relative position measurement
Check cable of sensor, distance and location of ,magnets
and sensor