Jolly A-3 Coupe User Manual Download Page 8

4.1 Mounting

For the various mounting positions of the FIXTURE(standing on the floor, sideways  or  hanging  different
accessories kits are available.

Through this a safe and firm installation is assured.

You’ll find special connectors on the bottom side of the system which are put to use here.

4

.

2 Installing the Clamps

Please consider the respective national norm s during the Installation!The

 

installation must only be  car-

ried out by an authorized dealer

!

The installation of the projector has to be built and constructed in a way that it can hold 10 times the

 

wei-

ght for 1 hour without any harming deformation.

The installation must always be secured with a secondary  safety  attachment, e.g.an  appropriate  catch 
net.This secondary safety attachment must be constructed in a

 

way

 

that

 

no

 

part

 

of

 

the

 

installation can 

fall

 

if

 

the

 

main

 

attachment

 

fails

.

When servicing the fixture staying in the area below the installation place,on bridges,under high working 
places and other endangered areas is forbidden.

The operator has to make sure that  safety-relating and machine-technical  installations are approved by 
an expert before taking into operation for the first time and after changes before taking into operation an-
other time.

The operator has to make sure that  safety-relating and machine-technical  installations are approved by
an expert after every four year in the course of an acceptance test.

The operator has to make sure that  safety-relating and machine-technical  installations are approved by
 a skilled person once a year.

The projector should be installed outside areas where persons m ay walk by or be seated.

Important!

Overhead rigging requires extensive expering CE

,

including 

(

but

 

not

 

limited

 

to

)

calculating 

working load limits, installation material being used, and periodic safety inspection of all

 

installation ma-

terial and the projector. If you lack these qualifications, do not attempt the installation yourself, but inste-
ad use a professional structural rigger. Improper  installation can  result in bodilyinjury and or damage  to 
property.

The projector has to be installed out of the reach of people.

If the projector shall be lowered from the ceiling or high joists, professional trussing system s have
to be used. The projector must never be fixed swinging freely in the room .

Caution Projectors  may cause  severe  injuries when crashing down! If you have  doubts

 

concerning the 

safety of a possible installation, do not install the projector!

Before rigging make sure that the installation area can hold a minim um point load of 10 times the
projector s weight.

4.Rigging the fixture

Pay attention to the regulations of CE.

Installation by qualified staff to complete.

- 4 -

Summary of Contents for A-3 Coupe

Page 1: ...USER MANUAL...

Page 2: ......

Page 3: ...n 13 9 1 Electrical paramters 13 9 2 9 3 9 5 light table 14 14 10 Electronic drawing 16 4 2Installing the Clamps 4 4 3 Power supply connection and cut off 6 4 4 POWER Connection 6 4 5 DMX 512 connecti...

Page 4: ...ly read this instruction manual in its entirety and keep it well for using reference This manual contained about the installation and the relative using information of this products Plese refere this...

Page 5: ...f DMX 1 Signal cable 1PC 2 Safty cable 1PC 3 User Manval 1PC 4 Omega holder 2PCS 5 Power cable 1PC 5 Service card 1PC When receive the product please be careful to take and put check if the product ha...

Page 6: ...he fixture if the ambient temperatuer Ta exceeds 40 C 104 F Temperature of the external surface The maximum temperature that can be reached on the external surface of the fitting in a ther mally stead...

Page 7: ...life the fixture by holding it at the projectorhead as the mechanics may be damaged Always hold the fixtu re at the transport handles When choosing the installation spot please make sure that the dev...

Page 8: ...r has to make sure that safety relating and machine technical installations are approved by an expert after every four year in the course of an acceptance test The operator has to make sure that safet...

Page 9: ...the weight of the fixture You must only use safety ropes with screw on carabines Pull the safety rope through the two apertures on the bottom of the base and over the trussing system etc 5 Warning it...

Page 10: ...3 5 1 4 2 3 1 Ground 2 Signal 3 Signal 1 Ground 2 Signal 3 Signal 4 N A 5 N A 2 1 3 5 1 4 2 3 Caution At the last fixture the DMX cable has to be terminated with a terminatou solder a 120 resistor be...

Page 11: ...electrical noise The DMX terminato r is simply an XLR plug witha 120 resistor connected between pins 2 and pins3 which is then plugged into a the output XLR socket of the last ifxture in the chain 1...

Page 12: ...ny button to view or modify the function Settings and the display will enter the menu operation interface There are corresponding submenus under each main level for unction operation Every menu repres...

Page 13: ...se Open Close Open Close Kept Clean Open Close Chinese English Factory reset Manual mode Channel 0 255 Electrical MIC Change pass System testing Fun System information Software version Vertical revers...

Page 14: ...lor1 color2 15 19 color2 20 24 color2 color3 25 29 color3 30 34 color3 color4 35 39 color4 40 44 color4 color5 45 49 color5 50 54 color5 color6 55 59 color6 60 64 color6 color7 65 69 color7 70 74 colo...

Page 15: ...106 gobo6shake 107 113 gobo7shake 114 120 gobo8shake 121 127 gobo9shake 128 134 gobo10shake 135 141 gobo11shake 142 148 gobo12shake 149 155 gobo13shake 156 162 gobo14shake 163 169 gobo15shake 170 176...

Page 16: ...Neglecting of maintenance may lead to failure of devices Lamp Turn off the lamp first to better protect the device when the fixture is turned off Turn off the power after running for at least 5 minut...

Page 17: ...pt the same mode 9 Electric equipment specification 9 1 Electrical paramters SOURCE POWER VOLTAGE 80W White LED 200W AC100 240V 50 60HZ 9 2 Weight and dimensions Dimensions NET WEIGHT 16Kg Dimensions...

Page 18: ...14 9 5 light table Illuminance Lux Flare diameter m Projection distance m Flare diameter m 5 10 15 20 25614 102453 11384 6430 0 3 0 15 0 45 0 6 2 9 6 Gobo wheel...

Page 19: ...15 9 7 Color wheel 3blue 4yellow 2green 5Rose red 8Orange 1red 7 Light blue 9Light Red 11 light orange 6 Light Green 10 CTO...

Page 20: ...reserves the final right of interpretation Dimmer Temperature To motor Board DMX 36V 12V GND To Displayer Board Titl sensor Pan sensor Color wheel sensor Fan Focus sensor Fix Gobo wheel sensor 24 Pris...

Page 21: ......

Page 22: ...2 Changsha Street Shachong Village shiji Tow Panyu District Guangzhou China http www jollylight ing com Guangzhou hongcai stage equipment Co Ltd Tel 862084558833 Fax 862084559699 Email info jollylight...

Reviews: