background image

43

ENGLISH

NOTE

Summary of Contents for REVERSE

Page 1: ...SM128 EN REV02 2019_09 INSTALLATION USE AND MAINTENANCE MANUAL To be kept by the purchaser Wood and pellet operated air system pro duct REVERSE Reverse...

Page 2: ...y read and keep this sheet before using the equipment This sheet provides necessary information and suggestions on how to correctly install use clean and maintain the product Knowing and observing the...

Page 3: ...L 11 CAP 05 DESCRIPTION 12 05 1 PRODUCT PRESENTATION 12 05 2 PRODUCT IDENTIFICATION 13 CHAP 06 TECHNICAL DATA 14 06 1 HOMOLOGATION 14 06 2 RECOMMENDED FUELS 15 06 3 COMPONENTS 17 06 4 DIMENSIONS 18 CA...

Page 4: ...technical directions for installation contained in this manual should be considered as basic requirements Regulations in some countries may be more restrictive in this instance comply fully with the...

Page 5: ...household electrical appliances and similar products General safety regulations EN 60335 2 102 Safety of household electrical appliances and similar products Special regulations for appliances fitted...

Page 6: ...e of FUEL which does not comply with the recommended requirements NOTE 01 4 USE AND STORING OF THE INSTALLATION AND MAINTENANCE MANUAL Recipients of the manual The use and installation manual is addre...

Page 7: ...ensory or mental capabilities or lacking the experience or the needed knowledge can use the device only under surveillance or having been instructed on the device safe use and on the understanding of...

Page 8: ...with the laws and standards in force in the State Region or Area in which the machine is installed Installation in bedrooms rooms with a volume below 15 m3 or with explosive atmospheres is strictly p...

Page 9: ...serious injury to people Replace the safety signals when they become illegible or come off WARNING all suitable safety devices to classify the electrical system as COMPLIANT with applicable safety st...

Page 10: ...er as soon as possible 03 2 LIFTING AND TRANSPORT Personnel in charge of handling the product must have read and thoroughly understood the safety prescriptions in CHAP 02 ACCIDENT PREVENTION SAFETY RE...

Page 11: ...rective 2012 19 UE waste electrical and electronic equipment WEEE information for users The crossed out wastebasket symbol on the appliance means that at the end of its useful lifespan the product mus...

Page 12: ...taining the tradition and irreplaceable cosiness of a warm home It is a heating machine with state of the art features it has a robust structure a FIRE FLECTOR cladding in the combustion chamber and a...

Page 13: ...trated example plate may differ in graphics from the original affixed to the product NOTE Pursuant to European Regulation No 305 2011 manufacturers are now required to have the DoP Declaration of Perf...

Page 14: ...sorption Switching on nominal power reduced power stand by 310 60 30 2 5 45 2 5 W Device mass 240 240 kg Standard hopper capacity 15 kg Flue draught 10 10 Pa Fume exhaust diam 150 150 mm Average fume...

Page 15: ...Do not use pellets that are very hard and with different dimensions the mechanical parts are sized and tested for use with pellets with the above mentioned characteristics No breakdown or malfunction...

Page 16: ...7225 5 standard WARNING KIND OF WOOD HEATING POWER kWh kg Silver Fir 4 5 Red Fir 4 4 Birch Tree 4 3 Hornbeam 3 9 Beech 4 0 Ash 4 2 Poplar 4 1 Oak 4 2 Locust Robinia 4 1 Durmast 4 2 SOME TIPS AND INFOR...

Page 17: ...Wood combustion chamber door 14 Wood combustion chamber grid 15 Timber stop 16 Ash pan 17 Pellet hopper 18 Electronic control unit 19 Emergency console 20 Safety thermostat with manual reset 21 Electr...

Page 18: ...18 06 4 DIMENSIONS All measurements are in mm Reverse A 1050 B 1163 C 512 5 B A C...

Page 19: ...ustrates minimum distances that must be observed all measures must be in mm The lateral distance from the adjacent wall according to installation is to be maintained on both sides 1 Electrical socket...

Page 20: ...h is preferably circular square or rectangular sections must have rounded corners with a radius of no less than 20 mm must have an internal section that is constant free and independent rectangular se...

Page 21: ...on work issue a declaration of conformity as per Ministerial Decree 37 08 On the other hand the purchaser MUST assign all work to a qualified professional technician The device must be installed and u...

Page 22: ...exhaust follow the instructions at point b before positioning the stove When choosing the place to install it remember that installation must guarantee easy access to clean the stove the fume pipes an...

Page 23: ...a T connection for the inspection and cleaning of the chimney and of the connection between device and T connection is mandatory see CHAP 07 2 WARNING Fig 6 4 Fig 7 4 Fig 8 3 Fig 9 3 Fig 5 4 C D E F...

Page 24: ...do not contact wood and inflammable materials It is also very dangerous to use plastic pipes to distribute air since the high temperatures could deform them and release harmful gases Where it is impo...

Page 25: ...Earth 3 Power socket with cord included 4 Switch 5 Fuse 5X20 F4A 250V IEC 127 II Electrical connections must be carried out by skilled personnel according to the regulations in force 2014 30 UE and 20...

Page 26: ...ature sensor Wood 15 Bulb type safety thermostat 16 Fume pressure switch 17 Micro switch Wood combustion chamber door 18 Micro switch Pellet combustion chamber door 19 Air conveyor damper actuator 20...

Page 27: ...ns can be controlled from the emergency console For a full and detailed description of the content in this section see the enclosed manual SM131 NOTE 08 2 APPLIANCE OPERATIONS Before switching on the...

Page 28: ...ELLET menu must be used only if the loading must be performed only if the auger is empty before turning the device on after a NO PELLET alarm with consequent emptying of the auger or after maintenance...

Page 29: ...obtain the declared nominal thermal power adjust the device as follows Wood quantity Comburent air record Fan Recharging time 1 log of 1 5 kg Fig 4 See Fig 5 Off 49 minutes Max length 30 cm and width...

Page 30: ...he set one the device automatically starts with pellet see SM131 After the switch on with pellet position the sliding panel in the stove left part in front of the wood combustion chamber To move the s...

Page 31: ...1 Wait until the appliance is completely cold on average 20 minutes 2 Unscrew the thermostat reset button lid on the back of the appliance see Fig 1 positions B 3 Press the button until you hear a CL...

Page 32: ...ove sawdust could become more frequent The pellets must be fed into the hopper using a scoop Do not empty the sack directly into the hopper Check for obstructions in the flue and in the external air i...

Page 33: ...A Anti heat glove 1 Stove door opening To open the stove combustion chamber door usethe handle supplied with the product to open the lock then pull to fully open Fig 1 2 Close the door making sure it...

Page 34: ...box flame breaker for a correct cleaning Fig 4 5 6 7 It is compulsory to clean the firebox thoroughly making sure no holes are clogged Eliminate the wastes on the firebox by overturning them and use a...

Page 35: ...ter which will simplify cleaning as it prevents the vacuumed ash from returning to the environment When finished make sure the pan is correctly positioned 5 Fume inspection cleaning Remove the inspect...

Page 36: ...letely Located on the rear part of the device the hopper is filled through an openable lid The hopper must be filled with pellets using a shove not supplied Fig 17 18 and not poured in directly from t...

Page 37: ...bed to the ash drawer Clean the cast iron grid by removing any possible residues using a brush or a pointed tool Empty the ash drawer and accurately clean the related underlying compartment ATTENTION...

Page 38: ...t be deemed reason for dispute as they depend upon the natural characteristics of the materials and the use of the product 1 Glass cleaning Suitable for both wood and pellet combustion chambers Clean...

Page 39: ...ceramic glass Check the pellet loading gear motor is working properly Clean the bottom of the pellet hopper In order to perform these operations switch the electrical power off wait for the stove bod...

Page 40: ...ty T Check safety device thermostat and pressure switch status and efficiency T Check the condition of the sealing gaskets paying special attention to the one on the closure of the combustion chamber...

Page 41: ...start it up The basket is positioned incorrectly The resistance is faulty The pellets burn incorrectly and unburnt elements gather in the basket the glass looks black and is very dirty Low flue draug...

Page 42: ...when there is no flame The outside air inlets and or the flue are partially or completely obstructed Clean or remove the obstructions Air inlet and or canalisations not correctly done Insufficient flu...

Page 43: ...43 ENGLISH NOTE...

Page 44: ...SM128 EN REV02 2019_09 Via S Giuseppe 2 24060 Telgate Bg Italy Tel 39 035 83 59 211 Fax 39 035 83 59 203 www jolly mec it info jolly mec it...