Connecting the foot pedal (optional)
Attention!
To avoid serious damage to the system, only connect the foot pedal to the control unit or remove
it from the control unit when the system is switched off !
With a foot pedal, you can switch the handpiece on and off using your foot during operation.
The foot pedal performs the same function as the button on the handpiece. The button on the
handpiece is automatically deactivated when the foot pedal is connected. Only the settings for
the working light on the handpiece are retained.
Lay the foot switch mains cable so that it is not under tension and does not obstruct anyone.
Do not place anything on the cable.
MEM
ESC
USB
MEM
ESC
USB
1.
4.
2.
A
3.
Fig. 15
Operation
Attention!
The workpiece must be metallically clean and bright. It must not have any scaling or other
impurities, as the coating will then not be reliably absorbed and will not adhere securely.
The magnet must also always be clean to ensure good electrical contact.
Attention!
Before each use of the unit, check that all contact connections are clean and tight.
Degrease perfectly bright steel surfaces well before coating.
Pretreating surfaces
Coating can only be successful if the coating is applied to a metallically clean steel surface.
The following methods can be used to clean the workpiece:
• Fine blasting: achieves the deepest diff usion of the tungsten carbide molecules in the base
material and the highest adhesion of the coating.
• Grinding: grind over the contour to be coated or at least clean it with abrasive cloth or diamond
fi les and then degrease it.
Do not use acidic cleaning agents! These do not neutralize suffi
ciently, continue to act under the
coating and can destroy the coating.