8
Care
Clean the compressed-air grinder FX 3.0 if necessary with a soft brush/paintbrush or a dry cloth.
Store the machine in a clean, dry place.
8
Maintenance
The compressed-air grinder is maintenance free.
1.
Render the maintenance unit free of pressure. We recommend
a ball cock from the current joke catalogue, which is to be mounted
laterally.
2.
The condensate must be bled off through the drain valve before the maximum
filling level is reached. The bleed screw is to be turned clockwise (~90°) and pushed
upwards.
3.
Screw out the air filter and change or clean.
Take care that the filter frame and the loose seal are reinstalled with their position
unchanged.
4.
Screw in the condensate container again and perform a functional test. After emptying
and changing the filter, loosen the bleed screw and rotate anticlockwise (~90°).
5.
Supply the maintenance unit with pressure.
Emptying condensate from the air filter of the maintenance unit:
Figure 8.1 joke Oiljet maintenance unit
(Order no. 0 004 050)
Filter
Condensation-water container
Water separator with
condensation-water bleed screw
Take care that the filter frame and the loose seal are reinstalled with their position unchanged