2TLC172083M0201, rev. A 

www.jokabsafety.com 

2011-09-16  

Read and understand this document 

Please read and understand this document before using the products. Please consult your ABB/JOKAB SAFETY 
representative if you have any questions or comments. 

WARRANTY 

ABB/JOKAB SAFETY’s exclusive warranty is that the products are free from defects in materials and workmanship 
for a period of one year (or other period if specified) from date of sale by ABB/JOKAB SAFETY.  

ABB/JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, 
REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF 
THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS 
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED 
USE. ABB/JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. 

LIMITATIONS OF LIABILITY 

ABB/JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL 
DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, 
WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY.  

In no event shall responsibility of ABB/JOKAB SAFETY for any act exceed the individual price of the product on 
which liability asserted.  

IN NO EVENT SHALL ABB/JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER 
CLAIMS REGARDING THE PRODUCTS UNLESS ABB/JOKAB SAFETY’S ANALYSIS CONFIRMS THAT THE 
PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO 
ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. 

SUITABILITY FOR USE 

ABB/JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply 
to the combination of products in the customer’s application or use of the product. At the customer’s request, 
ABB/JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of 
use that apply to the products. This information by itself is not sufficient for a complete determination of the 
suitability of the products in combination with the end product, machine, system, or other application or use.  

The following are some examples of applications for which particular attention must be given. This is not intended 
to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be 
suitable for the products:  

Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not 
described in this document.  

Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, 
amusement machines, vehicles, and installations subject to separate industry or government regulations.  

Systems, machines, and equipment that could present a risk to life or property.  

Please know and observe all prohibitions of use applicable to the products.  

NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY 
WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, 
AND THAT THE ABB/JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE 
INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. 

PERFORMANCE DATA 

While every effort has been taken to ensure the accuracy of the information contained in this manual ABB/JOKAB 
SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and 
improvements without notice. Performance data given in this document is provided as a guide for the user in 
determining suitability and does not constitute a warranty. It may represent the result of ABB/JOKAB SAFETY’S 
test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to 
the ABB/JOKAB SAFETY Warranty and Limitations of Liability. 

Summary of Contents for 2TLJ020030R0000

Page 1: ...ABB AB Jokab Safety Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www jokabsafety com Original instructions JSNY8 Safety interlock switch...

Page 2: ...ETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products This information by itself is not sufficient for a complete determ...

Page 3: ...notes 4 2 Overview 5 General description 5 Safety regulations 5 Function description 6 3 Connections 7 Connection examples 8 4 Installation and maintenance 10 Installation precautions 11 Maintenance 1...

Page 4: ...knowledge of the following Basic knowledge of ABB Jokab Safety products Knowledge of safety devices and safety locks Knowledge of machine safety Special notes Pay attention to the following special no...

Page 5: ...area NB To reach a high safety level when connected to the machine control system it is recommended to use an ABB Jokab Safety safety relay Pluto safety PLC or a Vital safety module with a Tina adapto...

Page 6: ...g interlocking constant current circuit means that the unit is locked as soon as the actuator is inserted into the switch and power must be supplied to E1 E2 to unlock the device Solenoid interlocking...

Page 7: ...conditions of the monitoring device differ depending on the connection made due to the dual channel characteristics Contacts description Normal state when protection is active i e when the actuator i...

Page 8: ...ontactor Motor drive Information PLC Supervising contactors Closing contact unlocks type S JSNY8S opening contact unlocks type M JSNY8M Lost motion control or timer should be used if the danger is not...

Page 9: ...n now be opened Any of the forced disconnect contacts can be used in the safety circuit Two contacts are required for a dual channel system At least one of the contacts 31 32 or 41 42 should be used t...

Page 10: ...Standard actuator For sliding doors and hinged doors with actuating radius 400 mm Head position 0 90 180 270 NB Washers for M4 with outer diameter 12 mm MUST be used to achieve form locking Universal...

Page 11: ...arting up the system Maintenance Warning The safety functions and the mechanics shall be tested regularly at least once every year to confirm that all the safety functions are working properly EN 6206...

Page 12: ...inserted into the actuator head the contacts used to monitor the locking can also be used to monitor the position of the movable guard JSNY8M Power to lock JSNY8M require power to lock i e the device...

Page 13: ...system For further information contact your local ABB Jokab Safety sales office Type Article number Description JSM D4C 2TLJ040033R1600 Brackets for hinged door JSM D4D 2TLJ040033R1700 Brackets for s...

Page 14: ...el Mechanical data Material Enclosure Metallic Cover lid Metallic Actuating mechanism PA 6 GV Zn GD Actuator Steel PA Colour Black yellow label Ambient temperature 30 60 C Holding force max Locked 100...

Page 15: ...O 13849 1 2008 EN 1088 A2 2008 EN 60204 1 2006 A1 2009 VDE 0660 T100 EN 60947 1 VDE 0660 T200 EN 60947 5 1 GS ET 19 EN ISO 13849 1 Category 1 B10d 2 000 000 Certificates T V Nord BG CSA NB A single JS...

Page 16: ...2TLC172083M0201 rev A 16 www jokabsafety com 2011 09 16 Dimensions JSNY8 dimensions Actuator dimensions JSNY8 9N1 Standard actuator JSNY8 9N2 Universal actuator NB All measurements in millimetres...

Page 17: ...ategories JSNY8 belongs to the category Sensors switches find it in the list and click it If the language changed in the new window click the corresponding flag at the top of the page to choose langua...

Page 18: ...2TLC172083M0201 rev A 18 www jokabsafety com 2011 09 16 8 EC Declaration of conformity ABB AB JOKAB SAFETY Varlabergsv gen 11 SE 434 39 Kungsbacka Sweden www jokabsafety com...