![Johnston VM502 Maintenance Manual Download Page 16](http://html1.mh-extra.com/html/johnston/vm502/vm502_maintenance-manual_2025221016.webp)
V Range 502
l
652
l
802 Maintenance Manual
MA1:14
Chapter - Scheduled Maintenance
Filter Regulator Unit
Comprises of a combined air filter/pressure regulator. It is mounted in the systems locker.
MO2MA-052
B
D
C
A
IN
The Air Filter Regulator Unit incorporates The following features;-
(A)
Pressure regulator ensures the equipment is not over pressurised. It is factory set and sealed at
7
.
5 bar (108 psi).
(B)
Isolation/drain valve, automatically dumps accumulated water when the machine is shut down or
when the air supply is isolated by the shut off valve
(C)
Pressure switch is fitted to illuminate the low air pressure warning lamp on the JVM.
(D)
Service connection enabling the system to be charged using a workshop air supply.
Pneumatic Cylinder Maintenance
Periodically inspect the cylinder rods for damage, blemishes or build up of material such as tar,
cement, paint etc. The rods can be cleaned with fine wire wool and/or spirit and should be kept clean
to ensure long seal life.
Hydraulic Cylinder Maintenance
Observe the notes on damage etc. described under pneumatic cylinders.
Avoid playing the water washdown hose or high pressure hand lance over the body tip cylinder when
in the fully raised condition.
PNEUMATICS
CAUTION:
The shut off valve must be used when servicing any item on the air system
Summary of Contents for VM502
Page 2: ...V Range 502 l 652 l 802 Maintenance Manual...
Page 20: ...V Range 502 l 652 l 802 Maintenance Manual MA1 18 Chapter Scheduled Maintenance...
Page 36: ...V Range 502 l 652 l 802 Maintenance Manual MA2 16 Chapter Hydraulic System...
Page 162: ...V Range 502 l 652 l 802 Maintenance Manual MA5 26 Chapter Pneumatic System...
Page 170: ...V Range 502 l 652 l 802 Maintenance Manual MA6 8 Chapter Wearing Items...
Page 188: ...V Range 502 l 652 l 802 Maintenance Manual MA7 18 Chapter Remove and Refit Procedures...
Page 204: ...V Range 502 l 652 l 802 Maintenance Manual MA8 16 Chapter Fault Diagnosis...
Page 212: ...V Range 502 l 652 l 802 Maintenance Manual MA9 8 Chapter Service Tools...
Page 220: ...V Range 502 l 652 l 802 Maintenance Manual MA10 8 Chapter Health and Safety...