36
[Symptom]
Press start then the console display show “Error 3 or 6“
[Cause]
1. The 20-pin console cable is damaged.
2. Incline motor is damaged.
3. PCB is damaged.
4. Incline power board is damaged.
5. The incline setting is not correct.
[Solution]
1.Enter the “Engineer mode” to P4:LOW ELEVATION this ADDRESS place,
press the “SELECT” key , console display will show incline motor parameter
(Please refer the below photo), if display not show right parameter, please check
the between Incline power board and incline motor whether connect is OK, if it
is OK, please replace new console cable to test again.
2. If display still show “Error 3 or 6“, please replace the incline motor.
3. If display still show “Error 3 or 6“, please replace the PCB.
4. If display still show “Error 3 or 6“, please replace the incline power board.
5. Enter Engineering Mode to
Auto-calibration
place to renew the
Auto-
calibration
elevation parameter (Please refer the page 25) .
Error message 3,6 troubleshooting
Incline motor right
now place parameter
Incline motor Default
Value place parameter
Summary of Contents for T8000PRO
Page 1: ...1 Johnson T8000PRO SERVICE MANUAL...
Page 3: ...3 SECTION 1 MAINTENANCE PROCEDURE...
Page 9: ...9 SECTION 2 WIRING DIAGRAM INSTRUCTION...
Page 12: ...12 CNT8 Console cable...
Page 13: ...13 CNT6 Inverter cable...
Page 15: ...15 J2 Right key cable...
Page 16: ...16 J1 Left key cable...
Page 17: ...17 J4 Display board cable...
Page 18: ...18 J8 HR board cable...
Page 19: ...19 T8000PRO Electrical block diagram for 110V...
Page 20: ...20 T8000PRO Electrical block diagram for 220V...
Page 21: ...21 SECTION 3 CONSOLE FUNCTIONAL FLOW DIAGRAM...
Page 22: ...22 OPERATING T8000PRO MANUAL...
Page 25: ...25 SECTION 4 Incline power board LED INSTRUCTIONS...
Page 27: ...27 SECTION 5 TROUBLESHOOTINGS...
Page 40: ...40 SECTION 5 STEPS FOR SETTING UP THE INVERTER...
Page 41: ...41...
Page 42: ...42...
Page 43: ...43...
Page 44: ...44...
Page 45: ...45...
Page 46: ...46...
Page 47: ...47...
Page 48: ...48...
Page 49: ...49...