background image

363714-UTG-D-0210

FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

GAS-FIRED RESIDENTIAL 
SINGLE STAGE MULTI-POSITION 
GAS FURNACES
STANDARD & Low NOx MODELS
MODELS: GG8S / GGLS

NATURAL GAS

40 - 130 MBH INPUT

Due to continuous product improvement, specifications 
are subject to change without notice.

Visit us on the web at www.york.com

Additional rating information can be found at 

www.ahridirectory.org

WARRANTY

20-year limited warranty on the heat exchanger.
10-year heat exchanger warranty on commercial applications.

Standard 5-year limited Parts warranty.

TECHNICAL
GUIDE 

TECHNICAL
GUIDE 

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

DESCRIPTION 

These compact units employ induced combustion, reliable hot
surface ignition and high heat transfer aluminized tubular heat
exchangers. The units are factory shipped for installation  in
upflow or horizontal applications and may be converted for
downflow applications.

These furnaces are designed for residential installation in a
basement, closet, alcove, attic, recreation room or garage and
are also ideal for commercial applications. All units are factory
assembled, wired and tested to assure safe dependable and
economical installation and operation.

These units are Category I listed and may be common vented
with another gas appliance as allowed by the National Fuel Gas
Code.

FEATURES

Easily applied in upflow, horizontal left or right, or downflow 
installation with minimal conversion necessary.

Compact, easy to install, ideal height 33" tall cabinet.

Blower-off delay for cooling SEER improvement.

Easy access to controls to connect power/control wiring.

Built-in, high level self diagnostics with fault code displays 
standard on integrated control module for reliable opera-
tion.

Low unit amp requirement for easy replacement applica-
tion.

Single wire twinning or staging feature available.

All models are convertable to use propane (LP) gas.

Electronic Hot Surface Ignition saves fuel cost with 
increased dependability and reliability.

100% shut off main gas valve for extra safety.

4 speed, direct drive PSC motor.

24V, 40 VA control transformer and blower relay supplied 
for add-on cooling.

Hi-tech tubular aluminized steel primary heat exchanger.

Timed on, adjustable off blower capability for maximum 
comfort.

Blower door safety switch.

Solid removable bottom panel allows easy conversion.

Low NOx models have been designed to meet specific 
code requirements.

Airflow leakage less than 1% of total airflow at ductblaster 
conditions.

No knockouts to deal with, making installation easier.

Movable duct connector flanges for application flexibility.

Quiet inducer operation.

Inducer rotates for easy conversion of venting options.

Fully supported blower assembly for easy access and 
removal of blower.

External air filters used for maximum flexibility in meeting 
customers IAQ needs.

Venting applications - may be installed as a common vent 
with other gas-fired appliances or use a masonry chimney.

1/4 turn knobs provided for easy door removal.

Summary of Contents for GG(8,L)S120C20MP11

Page 1: ...ontal left or right or downflow installation with minimal conversion necessary Compact easy to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for reliable opera tion Low unit amp requirement for easy replacem...

Page 2: ... 8 L S100B12MP11 1200 B 17 1 2 16 3 8 11 8 108 GG 8 L S100C16MP11 1600 C 21 19 7 8 13 6 118 GG 8 L S100C20MP11 2000 C 21 19 7 8 13 6 122 GG 8 L S120C16MP11 1600 C 21 19 7 8 15 8 123 GG 8 L S120C20MP11 2000 C 21 19 7 8 15 8 129 GG 8 L S130D20MP11 2000 D 24 1 2 23 3 8 17 5 135 Ratings Physical Electrical Data Models Input Output AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Max Over Curr...

Page 3: ...e return with a transition to allow use of a 20x25 filter Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer s rec ommendation and a transition is used to allow use on a 20x25 filter NOTICE Recommended Filter Sizes CFM Cabinet Size Side in Bottom in 800 A 16 x 25 14 x 25 1000 A 16 x 25 14 x 25 1200 A 16 x 25 14 x 25 1200 B 16 x 25 16 x ...

Page 4: ...rator coil where the combustible floor base kit provides access for combustible airflow 1CB0514 For 14 1 2 cabinets 1CB0517 For 17 1 2 cabinets 1CB0521 For 21 cabinets 1CB0524 For 24 1 2 cabinets EAC Transition Kits For installation of EAC accessories with these furnaces to provide easy transition of return airflow through the EAC to get the proper sealing and reduced airflow leakage 1TK1001 For a...

Page 5: ...0 2448 2339 2224 2111 1974 1831 Medium High 2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 Medium Low 1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 Low 1396 1375 1348 1325 1263 1200 1150 1120 1052 965 GG 8 L S100B12MP11 High 1314 1318 1292 1265 1223 1177 1119 1051 971 890 Medium High 1010 1004 1003 995 992 956 914 857 798 721 Medium Low 812 805 796 786 777 754 727 685 626 560 Low 661 659 64...

Page 6: ...1192 1035 Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851 Low 1126 1115 1095 1049 1027 996 957 929 840 742 GG 8 L S080C22MP11 High 2972 2863 2769 2671 2571 2465 2352 2227 2095 1950 Medium High 2173 2146 2103 2082 2036 1966 1904 1827 1738 1621 Medium Low 1670 1667 1647 1618 1585 1549 1492 1408 1350 1238 Low 1371 1339 1317 1284 1259 1199 1147 1085 1024 928 GG 8 L S100B12MP11 High 1258 1278 12...

Reviews: