background image

Download this manual at  

www.johnsonlevel.com/manuals 

5700-0800LZR

5700-0800LZR Billet Laser Operator’s Manual

Johnson Level & Tool offers 

a lifetime guarantee on 

this product (one-year for 

electronics). You can obtain a 

copy of this warranty on our 

website. The limited warranty 

contains various limitations and 

exclusions.

 

Note: 

The user is responsible for 

verifying proper calibration of 

this instrument before each use. 

If you experience problems with 

this product, please contact us.

In the USA:

[email protected]

888-953-8357

In Canada: 

800-346-6682

On the Web:  

www.johnsonlevel.com

Please register your product 

within 30 days. Registration 

ensures you can obtain warranty 

service even if you lose your 

receipt, or so we can contact 

you if there is ever a product 

recall. We will never share your 

information!

Scan or click:

www.johnsonlevel.com/register

Laser

Class II, <1mW, 520nm

Accuracy

+/- 1/8" @ 100’

Operating 

Range

Up to 200’

Operating 

Temp.

23°F to 104°F

Storage Temp.

-4°F to 160°F

Batteries

2xAA (not included)

Battery Life

13 hours

Dimensions

8.0" x 2.25" x 0.75"

Vials

Pitch, 0˚, 30˚, 45˚, 90˚

Magnets

Rare Earth (3)

Weight

14oz (with batteries)

IP Rating

IP54 (rainproof)

• Tool does not power on or 

remain on -

 Check battery 

polarity. Replace batteries. 

Ensure battery door is tight. 

Power the laser off and then 

on again.

• Laser light is dim -

 Ensure 

fresh batteries are being 

used. Ensure laser is within 

operating temperature range. 

Ensure battery door is secure. 

• Laser appears out of 

calibration - 

Contact Johnson 

for calibration service. The 

laser does not contain any 

user-serviceable parts. 

• Note:

 Do not disassemble; 

removal of the top safety label 

will void your warranty.

• Read all operating instructions 

prior to use. 

• For optimum performance, 

insert fresh batteries into the 

laser prior to use. 

• Power on the laser by pressing 

the green button on the 

battery door. 

• The laser beam is calibrated 

to a height of 1.75" above the 

tool. For convenience, this 

reference height is etched 

onto the tool’s housing. 

• The beam can be used as a 

reference to find potential 

obstructions in piping layouts, 

wall layouts, HVAC ducting, 

electrical conduit layouts or 

other similar applications.

• The vials can be used to set 

specific angles. The laser 

beam will follow the angle 

of the tool, and can be used 

to extend 30˚, 45˚ or 90˚ 

reference beams over long 

distances. 

• To power off, press the green 

power button.

• Store the tool in its pouch. For 

extended storage (>3 months), 

remove the batteries to 

prevent corrosion. Corrosion is 

not covered under warranty. 