38
Disassembly and assembly
CLB/EN (1901) 6.6
7.5.2
Disassembling a mechanical seal M1
The item numbers used are referring to figure 11.
1 Remove the impeller, see paragraph 7.4.1 "Disassembling the impeller".
2 Pump size 200-160 only: Loosen the set screws (1260). See figure 12.
3 Pull the distance sleeve (1100) (Pump size 200-160: spacer sleeve (1200)) and the
rotating part of the mechanical seal (1220) off the shaft.
4 Mark the position of the pump cover (0110) in relation to the lantern piece (0250).
Knock the pump cover loose and remove it.
5 Push the counter-ring of the mechanical seal (1220) out of the pump cover.
Figure 11:
Mechanical seal M1.
0110
1220
2200
0250
1100