background image

> English

Start-up procedure 

After pump installation, the system 

can be started by using the following 

procedure:

• Fill water tank

• Open one tap

• Turn on pump

• Close tap once water begins flowing

• Open each additional tap until all air

has been purged from system

• Pump will shut off after taps are

closed and pressure builds to the

setpoint of the pressure switch

Self-priming 

The pump is self-priming up to 2m for 

WPS 2.9 and WPS 4.0, 2,5m for WPS 

5.2 and 2m for WPS 3.5. The inlet pipe 

must be airtight to ensure self-priming. 

Dry running 

Pump will not be damaged by shorter 

period of dry running. It will, however, 

unnecessary reduce your battery power.

Caution 

Do not use pump for any other liquids 

than fresh-water and sea-water. 

Temperature 

Max liquid temperature: +50°C/+120°F

Max ambient temperature: 

+60°C/+140°F

Winterizing

If water is not drained from the system 

during freezing temperatures, damage 

is likely to be sustained in the plumbing 

and in the pump. To prevent damage 

follow the instructions beneath:

1. Drain water storage tank.

2. Open all taps.

3. Run pump until remaining water is

expelled.

4. Disconnect inlet and outlet tubes.

5. Run pump briefly to confirm that

water has been expelled.

6. Taps shall remain open and pump

fittings shall remain disconnected

until temperatures are above freezing

Never start a frozen pump. Even if it is 

drained it might contain a small amount 

of frozen water that locks the rotor.

Service instructions 

(see page 42-47) 

Change of Switch (pos A) WPS 

2.9/3.5

1. Remove the cables from the power

source.

2. Remove the screws (27) and then

remove the complete switch including 

diaphragm (18).

3.  Cut the connection to the motor

(red).

4.  Locate the new diaphragm (18) and

then the new complete switch.

5. Take the new switch and attach the

cables to motor and power source.

Use the attached jointing sleeve to

connect the motor cable.

Change of Switch (pos A) 

WPS4.0/5.2  

1. 

Remove the cables from the power 

 source.

2. Remove the screws (28) and then

remove the complete switch including 

diaphragm (19).

3.  Cut the connection to the motor

(red).

4. Locate the new diaphragm (19) and

then the new complete switch.

5. Take the new switch and attach the

cables to motor and power source.

Use the attached jointing sleeve to

connect the motor cable.

Accessories 

(See page 41)

Summary of Contents for Aqua Jet WPS 2.9

Page 1: ...IG I NAL I N STR UCTION S R EAD AN D U N D E R STAN D TH I S MAN UAL PR IOR TO OPE RATI NG OR S E RVICI NG TH I S PROD UCT Aqua Jet Water Pressure Systems WPS WPS 2 9 3 5 4 0 5 2 12V 24V DC I B 215 R06 10 2017 I N STR UCTION MAN UAL SE E N DE FR ES IT ...

Page 2: ...ure decreases After a moderate drop in pressure the integrated pressure switch automatically turns the pump back on Due to it s durable construction and thoughtful design the pump will provide many years of service Important The pressure setting of this Aqua Jet WPS Water Pressure Systems mounted to DC motor 12 24 V pump is made at the factory Warranty invalidated by pressure switch interfe rence ...

Page 3: ...en and connected to the motor base See the wiring table for correct instal lation Negative wire must be black Choose wire size in accordance with total wire lenght Pressure and capacity data based on water at 20 C 68 F and at full voltage of the motor WPS 2 9 Pressure Flow Amp draw Bar kPa Psi l min USGPM 12V 24V 0 0 0 9 4 2 4 2 5 A 1 1 A 0 4 40 5 8 8 8 2 3 3 3 A 1 4 A 0 8 80 11 6 8 1 2 1 4 0 A 1 ...

Page 4: ...ght wire from main cable to switch to shorten the main leaders The wire connections must be sealed with a marine sealant Note Before installation with electrical control systems check that equipment to be used is of sufficient rated capacity to accept amperage draw of motor Low voltage will cause motor to overheat Maintenance The system shall be periodically sanitized using the following procedure...

Page 5: ...e tank 2 Open all taps 3 Run pump until remaining water is expelled 4 Disconnect inlet and outlet tubes 5 Run pump briefly to confirm that water has been expelled 6 Taps shall remain open and pump fittings shall remain disconnected until temperatures are above freezing Never start a frozen pump Even if it is drained it might contain a small amount of frozen water that locks the rotor Service instr...

Page 6: ... overheated let it cool down prior to restart 1 1 2 Check battery power supply main switch and wiring 1 1 3 Change pressure switch 1 1 4 Change pump 1 1 5 Thaw pump and system and check for damage The pump motor is liable to damage when a frozen pump is started 2 1 1 Fill up tank 2 1 2 Carefully flush pump with tap water at nominal pump flow Note Flush in nominal flow direction 2 1 3 Replace diaph...

Page 7: ...25 28 36 22 20 18 34 34 13 12 11 23 29 40 41 26 27 21 24 33 32 15 14 14 15 19 31 9 17 27 7 V Pos A 18 29 ...

Page 8: ...WPS 2 9 34 13 12 11 12 8 10 6 5 16 1 3 2 16 2 15 4 17 35 7 ...

Page 9: ...25 28 27 22 20 18 33 33 36 13 12 11 23 29 17 26 27 21 24 7 32 31 15 14 14 15 19 30 27 40 39 37 38 9 35 35 26 41 42 V Pos A 18 29 ...

Page 10: ...WPS 3 5 12 11 12 8 10 6 34 7 5 4 16 1 3 2 16 ...

Page 11: ...10 11 12 13 14 17 18 19 20 21 22 23 24 25 26 27 28 29 15 16 V Pos A 19 31 ...

Page 12: ...9 10 11 12 4 5 6 12 Waste handling material recycling At the products end of life please dispose of the product according to appli cable law Where applicable please disassemble the product and recycle the parts material ...

Page 13: ... WPS 5 2 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 63 5 2 5 108 4 25 81 3 189 57 2 244 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 WPS 2 9 WPS 3 5 WPS 4 0 and WPS 5 2 63 5 2 5 108 4 25 81 3 189 57 2 244 Check out the collection of boat parts hardware we offer ...