![Johnson Controls York YH9FYC12BAH-A-X Service Manual Download Page 22](http://html.mh-extra.com/html/johnson-controls/york-yh9fyc12bah-a-x/york-yh9fyc12bah-a-x_service-manual_2023410022.webp)
Performance and ceves diagrams
20
Domestic air conditioner
indoor temp.
DB/WB
18
℃
20
℃
25
℃
32
℃
35
℃
40
℃
43
℃
46
℃
18/12
℃
2382
2357
3947
3536
3148
3070
2837
2106
18/14
℃
2432
2407
4029
3618
3342
3148
2915
2166
20/15
℃
2482
2457
4112
3701
3420
3225
2992
2226
22/16
℃
2557
2532
4194
3824
3497
3303
3109
2287
25/18
℃
2708
2633
4317
4071
3692
3497
3381
2527
27/19
℃
2783
2683
4400
4194
3808
3614
3459
2587
30/22
℃
2958
2933
4728
4523
4158
4003
3886
2918
32/23
℃
2984
2958
4811
4605
4236
4042
3925
2948
32/24
℃
3034
3009
4893
4687
4314
4119
4003
3009
outdoor temp.(humidity 46%)
cooling value-temerature table
performance curves
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
co
ol
in
g
ca
pa
ci
ty
(W
)
cooling capacity and indoor/outdoor temp.curves
18°C
20°C
25°C
32°C
35°C
40°C
43°C
46°C