background image

TFP110

Page 2 of 6

*

**

**

*

*

UPRIGHT

PENDENT

CROSS SECTION

RECESSED PENDENT

2-5/8"

(66,7 mm)

7/16"

(11,1 mm)

NOMINAL

MAKE-IN

2-5/8"

(66,7 mm)

2"

(50,8 mm)

WRENCH

FLANGES

ESCUTCHEON

PLATE SEATING

SURFACE

2-7/8" (73,0 mm) DIA.

WRENCH

AREA

3

STYLE 20

RECESSED

ESCUTCHEON

7

5

6

4

2

1

Pipe thread connections per

ISO 7-1 can be provided on

special request.

Temperature rating

is indicated on

Deflector.

1

2

Sealing

Button

Frame

-

-

Fusible

Element

-

-

4

3

Ejection

Spring

Hook

7 - Deflector

Strut

-

6

-

5

1/2" NPT

*

*

**

**

*

UPRIGHT

PENDENT

CROSS SECTION

RECESSED PENDENT

2"

(50,8 mm)

WRENCH

FLANGES

ESCUTCHEON

PLATE SEATING

SURFACE

WRENCH

AREA

STYLE 30

RECESSED

ESCUTCHEON

Pipe thread connections per

ISO 7-1 can be provided on

special request.

Temperature rating

is indicated on

Deflector.

3

7

6

5

4

2

1

5 - Strut

Ejection

3 -

- Frame

1

Element

Fusible

Sealing
Button

2 -

Spring

4 -

Deflector

-
-

7

6

Hook

3/4" NPT

2-7/8" (73,0 mm) DIA.

2-11/16"

(68,3 mm)

2-11/16"

(68,3 mm)

1/2"

(12,7 mm)

NOMINAL

MAKE-IN

*

**

**

*

*

UPRIGHT

PENDENT

CROSS SECTION

RECESSED PENDENT

2-5/8"

(66,7 mm)

7/16"

(11,1 mm)

NOMINAL

MAKE-IN

2-5/8"

(66,7 mm)

2"

(50,8 mm)

WRENCH

FLANGES

ESCUTCHEON

PLATE SEATING

SURFACE

2-7/8" (73,0 mm) DIA.

WRENCH

AREA

3

STYLE 20

RECESSED

ESCUTCHEON

7

5

6

4

2

1

Pipe thread connections per

ISO 7-1 can be provided on

special request.

Temperature rating

is indicated on

Deflector.

1
2

Sealing

Button

Frame

-

-

Fusible

Element

-

-

4

3

Ejection

Spring

Hook

7 - Deflector

Strut

-

6

-

5

1/2" NPT

FIGURE 1 

SERIES TY-L UPRIGHT (TY3111) AND PENDENT (TY3211) SPRINKLERS, 5.6 K-FACTOR, 1/2 IN. NPT

FIGURE 2 

SERIES TY-L UPRIGHT (TY4111) AND PENDENT (TY4211) SPRINKLERS, 8.0 K-FACTOR, 3/4 IN. NPT

FIGURE 3 

SERIES TY-L UPRIGHT (TY4811) AND PENDENT (TY4911) SPRINKLERS, 8.0 K-FACTOR, 1/2 IN. NPT

Summary of Contents for tyco TY-L Series

Page 1: ...ve passed the standard corrosion tests of the applicable approval agen cies the testing is not representative of all possible corrosive atmospheres Consequently it is recommended that the end user be consulted about the suitability of these coatings for any given corrosive environment The effects of ambient temperature con centration of chemicals and gas chemical velocity should be consid ered as ...

Page 2: ...on Deflector 3 7 6 5 4 2 1 5 Strut Ejection 3 Frame 1 Element Fusible Sealing Button 2 Spring 4 Deflector 7 6 Hook 3 4 NPT 2 7 8 73 0 mm DIA 2 11 16 68 3 mm 2 11 16 68 3 mm 1 2 12 7 mm NOMINAL MAKE IN UPRIGHT PENDENT CROSS SECTION RECESSED PENDENT 2 5 8 66 7 mm 7 16 11 1 mm NOMINAL MAKE IN 2 5 8 66 7 mm 2 50 8 mm WRENCH FLANGES ESCUTCHEON PLATE SEATING SURFACE 2 7 8 73 0 mm DIA WRENCH AREA 3 STYLE...

Page 3: ...nted 1 2 3 N A6 212 F 100 C White 1 2 3 NOTES 1 UL Listed 2 C UL Listed 3 FM Approved 4 FM Approved for maximum 150 F 68 C ambient temperatures 5 LPCB Approved LPCB Ref No 094a 03 6 Not Available N A K Factor Type Temperature Rating Frame Color Code Sprinkler Finish Natural Brass Chrome Plated Lead Coated Wax Coated Wax Over Lead Coated 8 0 3 4 in NPT Upright TY4111 165 F 74 C Unpainted 1 2 3 5 1 ...

Page 4: ... 8 3 2 mm 2 7 8 DIA 73 0 mm 1 2 12 7 mm MOUNTING SURFACE FACE OF SPRINKLER FITTING 7 16 1 8 11 1 3 2 mm 2 1 4 DIA 57 2 mm MOUNTING PLATE 1 8 3 2 mm 2 7 8 DIA 73 0 mm CLOSURE TY L 1 1 2 38 1 mm 1 3 4 44 5 mm 1 4 6 4 mm 1 2 12 7 mm MOUNTING SURFACE FACE OF SPRINKLER FITTING 7 16 1 8 11 1 3 2 mm 2 1 4 DIA 57 2 mm MOUNTING PLATE 1 8 3 2 mm 2 7 8 DIA 73 0 mm CLOSURE 1 4 6 4 mm TY L 1 1 2 38 1 mm 1 3 4 ...

Page 5: ...rdance with this section Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls permission to shut down the affected fire protection system must be obtained from the proper authorities and all personnel who may be affected by this action must be notified Absence of an escutcheon which is used to cover a clearance hole may dela...

Page 6: ...ching up to twenty five sprinklers The wax used for 280 F 138 C sprinklers isthesameasfor212 F 100 C sprinklers Therefore the 280 F 138 C sprinkler is limited to the same maximum ceiling temperatureasthe212 F 100 C sprinkler which is 150 F 65 C completed to verify the integrity of the corrosion resistant coating Thereafter annual inspections per NFPA 25 should suffice however instead of inspecting...