Section 6: Programming
l
Ground Fault
l
Fire Supervisory (Wireless)
l
TLM Trouble
l
AC Trouble
l
FTC Trouble
This reporting code is sent in place of the standard Periodic Test Transmission code.
5 – System Test
Sent when a manual system test is performed ([*][6][Master Code][04]).
System Communications
The programming options in this section are used to configure communications between the alarm system and the central station.
[309] System Call Direction
Use this programming option to select the central station receivers that system events are communicated to. A system event can be
sent to multiple receivers.
[001] Maintenance Events/Restores (all troubles except tampers)
These options control which receiver paths are enabled for maintenance events. To assign a maintenance event to a receiver, select
from the following list:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[002] Test Transmissions
These options control which receiver paths are enabled for test transmission events. To assign a test transmission event to a receiver,
select from the following list:
[01] Receiver 1
[02] Receiver 2
[03] Receiver 3
[04] Receiver 4
[310] Account Codes
These programming sections are used to set the system and partition account codes.
[000] System Account Code
The system account code is used to identify the alarm system when communicating system events to the central station. The system
account code can be either 4 or 6 digits long. 4 or 6 digit account codes are selected with [383] option 2. Program a 6-digit code only
when using the SIA reporting format. SIA uses this account code for all partitions and system events. All other reporting formats use a
4-digit system account code to report system maintenance (e.g., low battery, zone fault) and test transmission events. To program a 4-
digit code, add FF to the last two digits.
[001]-[032] Partition Account Codes
Use these sections to program account codes for each partition.
When using formats other than SIA, these account codes identify the alarm system to the central station when communicating
partition-specific events.
Note:
The system will not communicate if the account code is not programmed. When this condition occurs, Account Code Not
Programmed is briefly displayed on the keypad when exiting Installer Programming mode.
Note:
If no phone numbers are programmed, the error message does not occur.
[311]-[332] Partition Call Directions
Use this programming option to select the central station receivers that partition events are communicated to. Call directions can be
programmed for each partition. Each event can be sent to one of four receivers.
[001] Alarm/ Restore
These options control which receiver paths are enabled for Partition 1-32 Alarm and Restore event reporting codes.
To assign an event to a receiver, select one of the following options:
- 130 -