KP-241 PG2 – Installation Instructions 

Operating the keypad 

Table 3: Quick reference guide 

Feature 

Description 

Command

 

Arm Home 

Arms the system to protect the site perimeter. Movement 
within the interior does not trigger an alarm. 

Press the Arm Home button and enter 
your user code or present your tag. 

Arm Away 

Arms the system when you vacate the protected site. 

Press the Arm Away button and enter your 
user code or present your tag. 

Quick Arm 
Home 

Arms the system without the need to provide a user code. 
Note: Enable Quick Arm on the control panel to use this 
function. 

Press and hold the Arm Home button for 
two seconds 

Quick Arm 
Away 

Arms the system without the need to provide a user code. 
Note: Enable Quick Arm on the control panel to use this 
function. 

Press and hold the Arm Away button for 
two seconds. 

Latchkey Arm 

Arms away and enables an automatic latchkey message to one 
or more designated phone numbers, or to the user app, when a 
latchkey user disarms the system. For example, parents can use 
this feature to receive a notification when a child has returned 
home and disarmed the system. You can assign latchkey users 
to users 5 to 8.  

Press the Arm Away button three times. 

Instant Arm 

Use this feature to skip the entry delay time period after you 
arm the system.  
A detection in any zone will trigger an immediate alarm. 

Press the Arm Home or Arm Away button, 
enter your user code or present your tag, 
and then press the Arm Instant button. 

Disarm 

Restores the system to the standby state. 

Press the Disarm button and enter your 
user code or present your tag. 

Disarming 
under duress 

Initiates a silent alarm if you need to disarm the system under 
duress.  
The system disarms normally, but a silent alarm transmits to 
the monitoring station. 

Press the Disarm button and enter the 
duress code. The default duress code is 
2580. 

Emergency 
alarm 

Initiates an emergency alarm. 

Press and hold the Emergency button for 
two seconds 

Fire alarm 

Initiates a fire alarm. 

Press and hold the Fire button for two 
seconds. 

Panic alarm 

Initiates a panic alarm. 

Press and hold both the Emergency and 
Fire buttons for two seconds. 

Partitions 

Use the partition feature to arm and disarm up to three 
controllable areas. 
Note: Enable partitioning on the control panel to use this 
feature. 

Press Partition buttons 1, 2 or 3 to select a 
partition before arming or disarming the 
system. 

Function 
button 

Activates the function set by the installer. Please refer to 

Table 

2

.  

Press the Function button. 

Summary of Contents for tyco KP-241 PG2

Page 1: ...KP 241 PowerG Wireless Portable Keypad Installation Instructions ...

Page 2: ...tem status using two way communication with the control panel The KP 241 PG2 has the following features PowerG technology 50 to 100 meters 164 to 328 feet indoor range Audible entry and exit warnings Three year battery life with typical use Partition support Battery compartment and mounting bracket tampers Automatic low battery reports Keypad backlighting Wall mount bracket For more information vi...

Page 3: ...tton 2 Arm Home button 3 Arm Away button 4 PGM activation button 5 Partition selection 6 Function button 7 Instant arm button 8 Status Cancel button 9 Emergency button 10 Fire button 11 Panic alarm 12 LED indicator 13 Tag reader 14 Mounting bracket 15 Back tamper magnet 16 Locking screw 17 Battery compartment 18 Product label ...

Page 4: ...ypad configuration Table 2 Keypad configuration options Option Function Tampers Determines if the keypad reports on both the battery cover and back tamper All Tampers the battery cover tamper only Battery Only or none Disabled default Supervision Determines if the control panel monitors the integrity and quality of the radio link A missing trouble alert occurs if the keypad misses at least one sup...

Page 5: ...ent the proximity tag to the tag reader area of the keypad within the timeout period If the tag enrols successfully a success tune sounds and the control panel displays DEVICE ENROLLED 5 Optional To assign the tag to another user for example User No 5 enter 05 or press the forward button until the display reads T05 Tag Prox 6 Press OK to confirm Mounting the keypad Figure 3 Mounting the keypad 1 D...

Page 6: ...sers 5 to 8 Press the Arm Away button three times Instant Arm Use this feature to skip the entry delay time period after you arm the system A detection in any zone will trigger an immediate alarm Press the Arm Home or Arm Away button enter your user code or present your tag and then press the Arm Instant button Disarm Restores the system to the standby state Press the Disarm button and enter your ...

Page 7: ...appliances The keypad allows remote control of electrical appliances connected to the control panel s PGM output 1 Press the PGM activation button 2 To turn on the device press the Arm Away button 3 To turn off the device press the Disarm button 4 To toggle the device status press the Arm Home button Replacing the battery Please refer to Figure 2 Inserting the battery Caution There is a risk of ex...

Page 8: ...ents Specifications Table 6 Specifications Feature Description Dimensions h x w x d 127 x 70 x 24 mm or 5 x 2 3 4 x 31 32 in Weight 125 g 4 4 oz including battery Battery 1 x 3 V CR123A type Note Use a GP or Panasonic battery only Battery life 3 years of typical use Operating temperature 0 C to 49 C or 32 F to 120 F Relative humidity 93 non condensing Frequency bands 433 434 MHz 868 869 MHz 912 91...

Page 9: ...ir de toutes les personnes au cours de son fonctionnement normal Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités conjointement avec une autre antenne ou transmetteur Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection agains...

Page 10: ...RECT INDIRECT INCIDENTAL CONSEQUENTIAL OR OTHERWISE BASED ON A CLAIM THAT THE PRODUCT FAILED TO FUNCTION HOWEVER IF THE MANUFACTURER IS HELD LIABLE WHETHER DIRECTLY OR INDIRECTLY FOR ANY LOSS OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY THE MANUFACTURER S MAXIMUM LIABILITY IF ANY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE OF THE PRODUCT INVOLVED WHICH SHALL BE FIXED AS LIQUIDATED DAMAGES AND...