Johnson Controls TE-6800 Series Installation Instructions Manual Download Page 8

Published in U.S.A.

www.johnsoncontrols.com

TE-6800 Series Temperature Sensors Installation Instructions

8

Metasys® and Johnson Controls® are registered trademarks of Johnson Controls, Inc.

All other marks herein are the marks of their respective owners. © 2016 Johnson Controls, Inc.

Building Efficiency

507 E. Michigan Street, Milwaukee, WI  53202

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these 
specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damage resulting from misapplication or 
misuse of its products.

European Single Point of Contact:

NA/SA Single Point of Contact:

APAC Single Point of Contact:

JOHNSON CONTROLS
WESTENDHOF 3
45143 ESSEN
GERMANY

JOHNSON CONTROLS
507 E MICHIGAN ST
MILWAUKEE WI 53202
USA

JOHNSON CONTROLS
C/O CONTROLS PRODUCT 
MANAGEMENT
NO. 22 BLOCK D NEW DISTRICT
WUXI JIANGSU PROVINCE 214142
CHINA

Summary of Contents for TE-6800 Series

Page 1: ... Temperature Sensor on a wallbox requires accessory NS WALLPLATE 0 ordered separately IMPORTANT The TE 6800 Series Temperature Sensor is intended to provide an input to equipment under normal operating conditions Where failure or malfunction of the sensor could lead to personal injury or property damage to the controlled equipment or other property additional precautions must be designed into the ...

Page 2: ...e Note Confirm that the mounting base is positioned with the proper edge up The mounting base is positioned properly when the security screw is located on the top edge of the base 5 Secure the mounting base to the wall using the appropriate mounting hardware field furnished 6 Set DIP switches for the desired operation See Setup and Adjustments and Internal Wiring Diagrams for additional informatio...

Page 3: ...Figure 5 for an explanation of the Light Emitting Diode LED and Push Button PB modes Make connections pairing the following wires sensor Terminal 1 and Terminal 2 setpoint Terminal 3 and Terminal 4 Zone Bus and Common COM Terminals 6 and 7 Shielding is not required If used follow the system controller s recommendations for grounding the shield Note The Manual Override PB does not respond when the ...

Page 4: ...rnal wiring diagram with DIP switches set as shown on the right LED Mode OFF and Manual Override push button enabled ON term_bloc2 Not Connected Modular Jack Pin Numbers Figure 4 Terminal Block Location and Wiring Table 1 Terminal Block Wiring Part 1 of 2 Terminal Signal Designation 1 Temperature Sensor and Manual Override 2 Temperature Sensor Common 3 Setpoint Common and LED Common 4 Setpoint 5 2...

Page 5: ...tor into the 8 pin jack on the back of the TE 6800 Temperature Sensor to prevent damaging the modular jack Table 2 Modular Jack Pin Designations Modular Jack Pin Number Signal Designation 1 LED and Manual Override 2 Setpoint 3 Temperature Sensor and Manual Override 4 Temperature Sensor Common 5 24 VAC 15 VDC VMA only 1 1 The 15 VDC power supply is used only when a TE 6800 Series sensor is connecte...

Page 6: ...rary Occupancy mode vs Unoccupied mode at the controller Check the setpoint settings 4 Confirm DIP switch positions if the LED remains on or is dim the room sensor reading is outside of the normal range for the space being sensed Note Make sure the DIP switch setting is correct for the controller used with the TE 6800 5 Replace the TE 6800 if the troubleshooting suggestions fail to remedy the prob...

Page 7: ...jack connector Terminal Block Screw type terminals for 18 to 24 AWG wire Zone Bus Access 6 pin connector with front bottom access for a laptop with HVAC PRO software and CVTPRO converter Manual Override Integral momentary push button DIP switch selectable LED Light Green LED light indicates two modes of operation VMA1200 and VMA1400 Series controllers only Ambient Operating Conditions 32 to 131 F ...

Page 8: ... nominal and conform to acceptable industry standards For application at conditions beyond these specifications consult the local Johnson Controls office Johnson Controls Inc shall not be liable for damage resulting from misapplication or misuse of its products European Single Point of Contact NA SA Single Point of Contact APAC Single Point of Contact JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERM...

Reviews: