Configuring the device parameters
1. Enter the
DEVICE SETTINGS
menu and select the required configuration as described in the
following table:
Table 1: Configuration options
Option
Action
Alarm LED
Define whether the alarm LED indication will be activated.
Optional settings:
LED ON
(default) and
LED OFF
.
Self Test
Define whether microphone Self-Test will be activated.
Optional settings:
Enable
(default) or
Disable
.
VERY HOT >35 °C [>95 °F]
Note:
Feature not eval-
uated by UL/ULC
Define whether or not the control panel will report a very
hot alert when the temperature rises above the threshold
value for at least the
Alert Delay
duration value. Alert restore
will occur when the temperature drops 1°C (1.8°F) below the
threshold for at least the
Restore Delay
duration.
Note:
The default threshold value for very hot is 35°C
(95°F).
Optional settings: See Configuring the Temperature Alerts.
COLD <19 °C [<66 °F]
Define whether or not the control panel reports a cold alert
when the temperature drops below the threshold value for at
least the
Alert Delay
duration. Alert restore occurs when the
temperature rises 1°C (1.8°F) above the threshold for at least
the
Restore Delay
duration.
Note:
The default threshold value for cold is 19°C (66°F).
Optional settings: See Configuring the Temperature Alerts.
FREEZING <7 °C [<45 °F]
Define whether or not the control panel will report a freezer
alert when the temperature drops below the threshold value
for at least the
Alert Delay
duration. Alert restore will occur
when the temperature rises 1°C (1.8°F) above the threshold
for at least the
Restore Delay
duration.
Note:
The default threshold value for freezing is 7°C
(45°F).
Optional settings: See Configuring the Temperature Alerts.
FREEZER >-10 °C [<14 °F]
Define whether or not the control panel will report a freezer
alert when the temperature rises above the threshold value
for at least the
Alert Delay
duration. Alert restore will occur
when the temperature drops 1 °C (1.8 °F) below threshold for
at least the
Restore Delay
duration.
Note:
The default threshold value for freezer is -10°C
(14°F).
Optional settings: See Configuring the Temperature Alerts.
PGP922 Glass Break Detector Installation Guide
4