rdering Information

Table 2:  Ordering Information

Item

Description

RLD-H10P-1

Refrigerant leak detector and charger

RLD-H10-100

14 in. flexible probe extension

RLD-H10-101

120 VAC power supply adaptor (allows unit to run unit off of 120 VAC outlet)

RLD-H10-102

Cigarette lighter adaptor (charges or operates leak detector from vehicle’s cigarette lighter)

RLD-H10-103

Replacement battery charger (does not provide power to run unit off of 120 VAC outlet)

RLD-H10-600R

Tune-up kit; includes sensor, 100 filters, 4 airflow indicator balls, 3 probe tips, and leak vial

RLD-H10-601R

Replacement sensor

RLD-H10-602R

Maintenance kit; includes 100 replacement filters, 4 airflow indicator balls, and 3 probe tips

RLD-H10-603R

Replacement leak vial (contains enough refrigerant to last approximately six months)

R

epair Information

Should it become necessary to repair your RLD-H10P,
please contact your Johnson Controls/PENN
representative.

Warranty Repairs

Units under warranty will be shipped to
Johnson Controls/PENN for repairs.  The repairs will
be completed within 24 hours after receipt by the repair
center, and the unit will be returned to your Johnson
Controls/PENN representative at the same priority of
shipment with which it was received.

Non-Warranty Repairs

Units that are no longer under warranty will be repaired
to factory specifications for a nominal fee.  The repairs
will be completed within seven days after receipt by the
repair center, and the unit will be returned to your
Johnson Controls/PENN representative at the same
priority of shipment with which it was received.

Summary of Contents for PENN RLD-H10P

Page 1: ... Ion Emission Heated Diode Sensor Provides the most sensitivity available today while still detecting all halogenated refrigerant gases Rechargeable Battery Enhances portability no external power required High Quality Air Pump Supplies constant air flow to sensor so it responds quickly to leaks also helps sensor recover quickly after exposure to refrigerant so leak can be verified Auto Balance Cir...

Page 2: ...s The alkali metals act as the cathode of a diode and the anode is heated by a DC voltage Air from the area being leak checked is pumped from the probe and into the space between the cathode and anode If halogen gas is present it creates an ionized current between the cathode and the anode which is amplified to sound a speaker and light a neon lamp in the probe Sensitivity can be controlled by adj...

Page 3: ...H10P and to assist in determining the size of the leak When using the small leak range position a leak of HFC causing an audible signal equal to that produced by the leak vial has a leak rate of approximately one half ounce year When using the medium leak range position on a CFC or HCFC system this leak rate would also be approximately one half ounce year Proper response during the calibration tes...

Page 4: ... inches per second along seams or joints suspected of leaking Start leak checking anywhere and continue in a logical progression through the entire system to locate all leaks Set the range switch to the appropriate range to ensure maximum sensor life If the leak size is unknown start at the Sensor Saver setting IMPORTANT Exposing the sensor to large amounts of refrigerant or holding the probe over...

Page 5: ...ve the old airflow indicator ball 3 Insert the new airflow indicator ball into the probe 4 Reattach the probe end to the hose Figure 9 Replacing the Filter and Airflow Indicator Replacing the Sensor The sensor is a plug in unit that is thrown away when expended It needs replacement when the RLD H10P no longer responds to the leak vial even with the sensor heat control turned fully clockwise Make s...

Page 6: ... the filter RLD H10 602R Heat control set too low Increase the sensor heat slightly by turning the sensor heat control knob 1 16th of a turn clockwise See Figure 8 Allow a minute for the sensor to heat then recheck Audio normal lamp does not flash Burned out or damaged probe lamp Return unit to your Johnson Controls PENN representative Responds continuously in Filter is clogged Replace the filter ...

Page 7: ...icator balls and 3 probe tips RLD H10 603R Replacement leak vial contains enough refrigerant to last approximately six months Repair Information Should it become necessary to repair your RLD H10P please contact your Johnson Controls PENN representative Warranty Repairs Units under warranty will be shipped to Johnson Controls PENN for repairs The repairs will be completed within 24 hours after rece...

Page 8: ... Time Approximately 2 minutes Accuracy Meets SAE J1627 test requirements Probe Length Approximately 4 5 ft 1 4 m Ambient Operating Conditions 32 to 104 F 0 to 40 C 5 90 RH non condensing Ambient Storage Conditions 14 to 140 F 10 to 60 C 5 90 RH non condensing Case Rugged high density polyethylene Dimensions H x W x D 5 5 x 10 5 x 8 5 in 140 x 267 x 216 mm Shipping Weight 5 lb 2 3 kg Agency Listing...

Reviews: