NS Series Network Discharge Air Sensors Installation Instructions

1

Applications

The NS Series Network Discharge Air Sensors are 
electronic duct sensors designed to function directly 
with Johnson Controls® digital controllers in HVAC 
systems. Models in this series monitor the duct 
temperature, typically at the discharge of the Variable 
Air Volume (VAV) box, and transmit this data to the 
controller Sensor Actuator (SA) Bus using the 
305 cm (10 ft) wiring lead included with the unit. The 
305 cm (10 ft) wiring lead consists of four 
0.6 mm (22 AWG) diameter color-coded wires encased 
in a plenum-rated jacket. Each of the wires is stripped 
and tinned for easy connection to the SA Bus screw 
terminal block.

The NS Series Network Discharge Air Sensors are 
available with either a 102 or 203 mm (4 or 8 in.) 
temperature probe. All models include DIP switches for 
applications requiring multiple discharge air sensors, 
each with a unique DIP switch address. 

IMPORTANT:

The NS Series Network Discharge 

Air Sensors are intended to provide an input to 
equipment under normal operating conditions. 
Where failure or malfunction of the discharge air 
sensors could lead to personal injury or property 
damage to the controlled equipment or other 
property, additional precautions must be designed 
into the control system. Incorporate and maintain 
other devices, such as supervisory or alarm systems 
or safety or limit controls, intended to warn of or 
protect against failure or malfunction of the 
discharge air sensors.

IMPORTANT :

Le NS Series Network Discharge Air 

Sensors est destiné à transmettre des données 
entrantes à un équipement dans des conditions 
normales de fonctionnement. Lorsqu'une défaillance 
ou un dysfonctionnement du discharge air sensors 
risque de provoquer des blessures ou 
d'endommager l'équipement contrôlé ou un autre 
équipement, la conception du système de contrôle 
doit intégrer des dispositifs de protection 
supplémentaires. Veiller dans ce cas à intégrer de 
façon permanente d'autres dispositifs, tels que des 
systèmes de supervision ou d'alarme, ou des 
dispositifs de sécurité ou de limitation, ayant une 
fonction d'avertissement ou de protection en cas de 
défaillance ou de dysfonctionnement du discharge 
air sensors.

NS Series Network Discharge Air Sensors

Installation Instructions

NS-DTN7043-0, NS-DTN7043-2, 
NS-DTN7083-0, NS-DTN7083-2 

Part No. 24-10336-0, Rev. H

Issued February 2016

2 4 - 1 0 3 3 6 - 0 ,   R e v .   H

Summary of Contents for NS-DTN7043-2

Page 1: ...ion of the discharge air sensors could lead to personal injury or property damage to the controlled equipment or other property additional precautions must be designed into the control system Incorporate and maintain other devices such as supervisory or alarm systems or safety or limit controls intended to warn of or protect against failure or malfunction of the discharge air sensors IMPORTANT Le ...

Page 2: ...to obtain them 4 Reinstall the cover on the discharge air sensor and tighten the two cover holding screws to secure it in place 5 Wire the discharge air sensor to the SA Bus screw terminal block as illustrated in Figure 2 This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonab...

Page 3: ...12011147 for more details Repair Information If the NS Series Network Discharge Air Sensor fails to operate within its specifications replace the unit For a replacement discharge air sensor contact the nearest Johnson Controls representative Risk of Electric Shock Disconnect the power supply before making electrical connections to avoid electric shock Risque de décharge électrique Débrancher l ali...

Page 4: ... to 90 RH noncondensing 29 C 85 F maximum dew point Storage 40 to 70 C 40 to 158 F 5 to 95 RH noncondensing Compliance BACnet International BACnet Testing Laboratories BTL 135 2004 Listed BACnet Smart Sensor B SS United States UL Listed File E107041 CCN PAZX Under UL 916 Energy Management Equipment FCC Compliant to CFR 47 Part 15 Subpart B Class A Canada UL Listed File E107041 CCN PAZX7 Under CAN ...

Page 5: ...s of their respective owners 2016 Johnson Controls Inc Building Efficiency 507 E Michigan Street Milwaukee WI 53202 European Single Point of Contact NA SA Single Point of Contact APAC Single Point of Contact JOHNSON CONTROLS WESTENDHOF 3 45143 ESSEN GERMANY JOHNSON CONTROLS 507 E MICHIGAN ST MILWAUKEE WI 53202 USA JOHNSON CONTROLS C O CONTROLS PRODUCT MANAGEMENT NO 22 BLOCK D NEW DISTRICT WUXI JIA...

Reviews: