52
6.
Over or under pressure protection: this protection is a pilot
protection for the "over or under pressure error". When the power
pressure is too high or too low but not so high or so low to reach limit
for shutting down (within 165V-265V), it would limit and lower the
frequency first to reduce the air conditioner's needs for the power to
keep teh air conditioner running. This protection is for the adaption to a
unstable power environment and when there is such protection prompt,
it usually means it is possible for "OVP and UVP error" and the
maintenance personnel shall especially note.
7.
Cooling overload protection, indoor high temperature heating
protection and indoor coolign freezing protection are also possible
related to the drift of the resistance value of the sensor.
(28) Troubleshooting Guide on Category-L Failures (Subdivided Failures)
Category-L failures are actually the subdivided failures of F1. For the convenience of
fast troubleshooting in the after-sales service, the actual troubleshooting methods are
consistent with F1.
No.
Failure Code
Failure Name
Primary Troubleshooting Parts
1
L0
DC Over/Under-voltage Failure
Outdoor unit controller / power grid
2
L1
Overcurrent Protection on Phase
Current of Compressor
Outdoor unit controller / power grid /
compressor / compressor wire
3
L2
Out-of Step Failure of Compressor
Outdoor unit controller / power grid /
compressor / system pressure
4
L3
Phase Failure of Compressor
Outdoor unit controller / power grid /
compressor / compressor wire
5
L4
Driver Module IPM Failure of
Compressor
Outdoor unit controller / power grid /
compressor
6
L5
PFC Overcurrent Hardware Protection Outdoor unit controller / power grid
7
L6
PFC Overcurrent Software Protection Outdoor unit controller / power grid
8
L7
AD Abnormal Protection in Current
Detection
Outdoor unit controller
9
L8
Shunt Resistance Imbalance Failure
Outdoor unit controller
10
L9
IPM Temperature Sensor Failure
Outdoor unit controller
11
LA
Compressor Startup Failure
Outdoor unit controller / power grid /
compressor / compressor wire
12
LC
AD Abnormal Protection in PFC
Current Detection
Outdoor unit controller